Honeywell ASY782-030 Câble Connecteur LED 30-FT

Honeywell ASY782-030 Câble Connecteur LED 30-FT

Il ne reste que 7 article(s) en stock
  • Fabricant : Honeywell

  • N° de produit : ASY782-030

  • Pays d'origine :États-Unis

  • Type de produit : Câbles de connecteurs industriels

  • Paiement : Virement bancaire, Western Union

  • Poids : 5000g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

Engineered specifically to facilitate reliable signal distribution in rugged industrial environments, the Honeywell ASY782-030 functions as a heavy-duty connector cable assembly with an integrated diagnostic status indicator. This 30-foot (9-meter) cable enables direct physical and electrical connection between field sensors, actuators, or burner control system components and local control panels. The embedded LED indicator provides immediate, high-visibility visual feedback on power availability and signal status at the coupling point, minimizing troubleshooting downtime. Built with an oil-resistant, robust jacket, this assembly resists mechanical wear and chemical exposure typical of industrial manufacturing settings.

Features

  • Status Indicator: Integrated inline LED provides real-time signal and power verification at the physical junction.
  • Generous Cable Run: 30-foot (9-meter) overall length supports long-distance routing across cable trays and conduit runs.
  • Industrial Durability: Resilient outer jacket provides excellent protection against moisture, mechanical abrasion, and common industrial oils.
  • Molded Coupling: High-integrity molded connector body prevents ingress of particulate matter and fluids at the termination point.
  • Stripped Lead Ends: Free end features pre-stripped conductors for fast terminal block termination inside control panels.

Applications

  • Burner control systems and flame safeguard monitoring integration.
  • Remote industrial sensor-to-junction-box signaling loops.
  • Process control setups requiring localized visual verification of active power paths.
  • Heavy-duty machinery wiring in automotive, petrochemical, and packaging plants.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Honeywell
Model Number ASY782-030
Cable Length 30 Feet (9 Meters)
Diagnostic Indicator Integrated LED Status Light
Connector Style Molded Industrial Connector to Stripped Flying Leads
Jacket Characteristics Oil-resistant, high-flexibility synthetic polymer
Country of Origin United States (or as specified by OEM)
Shipping Weight (Calculated) 2.2 kg (Estimated)

Empirical Engineering Insights

Alternative Models & Compatibility

The ASY782-030 shares pin layouts and operational design parameters with the shorter 15-foot variations (such as the ASY782-015). For systems requiring shorter physical loop distances without cable slack management, the shorter versions can be swapped directly. Ensure your electrical drawings are updated if changing run lengths, as loop resistance differs slightly over long distances.

Application Pitfalls & Engineering Notes

When deploying the 30-foot run, ensure the cable is not routed in immediate parallel proximity to high-voltage AC motor drives or heavy switching contactors to prevent electromagnetic interference from distorting low-level control signals. Although the cable outer jacket is highly durable, avoid placing sharp 90-degree bends immediately behind the molded LED connector body to prevent premature strain-relief failure under high vibration.

Commissioning & Wiring Tips

The integrated diagnostic LED relies on correct electrical polarity. If the connected device is operational but the LED does not illuminate, verify that the signal positive and return lines are not transposed. Always terminate the shield drain wire (if equipped) strictly at the panel ground bus and never at both ends, thereby preventing ground loop interference across the 9-meter distance.

Installation Guidelines

CRITICAL WARNING: De-energize all associated controllers, primary power supplies, and output relays before initiating installation or maintenance on this cable assembly. Verify that no voltage is present on the terminal block using a calibrated digital multimeter. Failure to isolate power can result in equipment damage, false triggering of safety loops, or electrical shock.
1
Inspect the molded connector end of the cable for dust, debris, or bent pins before physical engagement. Ensure the receiver socket on the device is completely clean and dry.
2
Align the physical keyway on the molded connector to the socket. Push the plug firmly home and secure the retention mechanism (coupling nut or latch) to preserve IP environmental protection ratings.
3
Route the 30-foot cable run through protective conduit or on designated trays. Maintain a minimum bend radius of ten times the overall cable diameter to prevent internal wire damage.
4
Strip the outer jacket at the control panel end to reveal the conductor insulation. Terminate according to the terminal assignments outlined in your system electrical drawings, and torque terminal block screws to the specified tension.
5
Apply system power. Trigger the field device and verify that the inline status LED lights up to confirm signal flow and power path verification.
Loading product navigation…

Quelle est la fonction principale de la LED intégrée sur ce câble ?

La LED intégrée fournit une vérification visuelle de l'état d'alimentation et de la transmission active du signal directement à l'interface de connexion, facilitant ainsi un diagnostic rapide sur le terrain et le dépannage du système.

Ce câble peut-il être utilisé dans des environnements industriels avec brouillard d'huile ou humides ?

Oui, le câble est doté d'une gaine extérieure industrielle résistante à l'huile, conçue pour maintenir son intégrité mécanique et électrique lorsqu'il est exposé à des lubrifiants industriels et à l'humidité.

Quelle est la configuration standard des broches et la terminaison de ce produit ?

Le câble se termine par un connecteur industriel moulé et pré-câblé à une extrémité et des fils dénudés à l'autre, permettant une connexion flexible aux entrées correspondantes du contrôleur ou aux borniers.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les systèmes à fluide : un guide pratique d'automatisation industrielle

Cet article explique comment les actionneurs électriques intégrés, tels que la série e-Actuator de SMC, transforment le contrôle du mouvement industriel en remplaçant les systèmes pneumatiques et...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...