To manage safety-critical field actuators within Honeywell Safety Manager environments, the FC-SDOL-0424 serves as a ruggedized fail-safe digital output module. This industrial component features four monitored output channels designed to drive 24 Vdc loads such as solenoid valves, indicators, and interposing relays up to 1 A per channel. Built-in short-circuit protection and overload detection mechanisms ensure high system availability and safety integrity in demanding industrial process control topologies. Each channel is monitored for line monitoring capabilities, allowing the safety controller to track field-side wiring integrity in real time.

Features

  • Four independent, short-circuit proof solid-state source output channels operating at 24 Vdc.
  • High-integrity diagnostic functions including overload detection and off-state leakage monitoring.
  • Internal fail-safe architecture designed for high-availability Safety Instrumented Systems (SIS).
  • Compact physical footprint conforming to standard Eurocard dimensions (4 HP width, 3U height).
  • Integrated watchdog (WDG) input verification to align output states with controller commands.

Applications

  • Emergency Shutdown Systems (ESD) in petrochemical plants.
  • Fire and Gas (F&G) mitigation control and alarming networks.
  • Burner Management Systems (BMS) in industrial boilers and power generation facilities.
  • Critical process safety interlocks in water treatment and chemical refineries.

Technical Specifications

Manufacturer Honeywell
Part Number/Model FC-SDOL-0424
Module Type Digital Output Module (Fail-safe)
Number of Channels 4
Output Configuration 24 Vdc solid-state source (short-circuit proof)
Maximum Channel Current 1 A
Maximum Total Module Load 3.6 A (dissipation limit)
Maximum Load Inductance 0.5 H
Maximum Load Capacitance 1 uF
Overload Detection Threshold Greater than 10 Ohm
Cold Lamp Resistance Greater than 20 Ohm
Voltage Drop Less than 1.3 V at 1 A
Off-state Leakage Current Less than 0.1 mA
Current Sense Voltage Drop Less than 1 V at 1 A
Watchdog (WDG) Input Current 4 mA
Power Requirements (5 Vdc) 15 mA
Power Requirements (24 Vdc Internal) 50 mA
Power Requirements (24 Vdc External) 15 mA (without output load)
Space Requirements 4 TE, 3 HE (4 HP, 3U rack space)
Shipping Weight 2 kg

Installation Guidelines

  • Mounting: Insert the module into an allocated slot within a compatible 3U Safety Manager rack, ensuring secure locking and alignment with backplane connectors.
  • Wiring: Field connection paths must use correctly rated wire gauges to handle continuous 1 A loads. Route low-voltage diagnostic lines separated from high-current AC power cables.
  • Cooling: Maintain clearance margins at the top and bottom of the subrack assembly to allow convective airflow, keeping operating temperatures within specifications.

Compliance and Certifications

  • CE
  • TUV (for safety instrumented functions up to SIL 3)
  • UL Listed
  • CSA Certified
  • FM Approved (Class I, Division 2 Hazardous Locations)
Loading product navigation…

What is the maximum output current capacity per channel for the FC-SDOL-0424?

Each of the 4 channels supports a maximum continuous current of 1 A, with a maximum module-wide load limit of 3.6 A due to thermal dissipation parameters.

Does the FC-SDOL-0424 digital output module support short-circuit protection?

Yes, the module is equipped with solid-state source outputs that are fully short-circuit proof and include overload detection thresholds.

Which safety systems is the FC-SDOL-0424 compatible with?

The module is designed for Honeywell Safety Manager systems and is certified by TUV for use in safety instrumented systems (SIS) up to SIL 3.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...