The TK-FPCXX2 is a chassis-mounted hardware component configured as a dedicated Power Supply Module within the Honeywell C200 and Experion control system architecture. This module provides critical voltage conversion and stabilization functions, transforming high-voltage alternating current (AC) source inputs into clean, regulated direct current (DC) power required to operate internal backplane components and adjacent process controllers. It features a user-selectable dual input voltage configuration range to ensure adaptability across varying international electrical distribution systems. Built with internal filtering and surge supression mechanisms, the hardware dampens transient line anomalies and manages thermal dissipation profiles effectively to ensure continuous loop uptime in harsh processing environments.
Features
Selectable dual-range alternating current input configurations.
High thermal tolerance delivering steady-state output performance up to 60 Celsius.
Managed inrush current mitigation protecting internal circuit pathways.
Compact physical footprint optimized for standard chassis integration.
Applications
Main infrastructure power delivery for C200 controller racks.
Distributed Control Systems (DCS) system-tier power regulation.
Critical processor rack utility support in petrochemical and refinery plants.
Subsystem automation power alignment inside power generation facilities.
Technical Specifications
Parameter
Specification
Manufacturer
Honeywell
Model
TK-FPCXX2
Product Type
Power Supply Module
Product Series
C200 / Experion System
Input Voltage Range
85-132 VAC or 170-265 VAC (selectable)
Input Power
150 VA, 92 W
Maximum Inrush Current
15 A
Frequency Range
47-63 Hz
Total Power Output Maximum
70 W @ 60 Celsius
Dimensions (L x D x H)
11.2 x 14.5 x 14.0 cm
Weight
1.1 Kg
Shipping Weight
2.5 Kg
Country of Origin
United States / Global Operations
Installation Guidelines
Input Voltage Selection
Prior to mounting the module or applying primary power, explicitly verify the position of the input voltage selection mechanism. Ensure it matches the local plant supply network (85-132 VAC or 170-265 VAC) to prevent immediate terminal or internal structural component damage.
Grounding and Shielding
Securely bond the primary equipment chassis rack to the main factory instrument ground grid via a heavy-gauge low-impedance copper strap. Ensure structural backplane grounding points are free of non-conductive coatings to guarantee continuous path integrity.
Cooling and Ventilation
The module dissipates operational heat and is rated for a maximum of 70 W output at 60 Celsius. Maintain free vertical spacing and clear ventilation lanes above and below the installation rack to facilitate unhindered air convection across the enclosure.
Wiring and Inrush Considerations
Ensure incoming power feed wiring is sized appropriately to handle the maximum rated 15 A inrush current transient during initialization cycles. Route AC mains distribution cables through separate physical containment channels away from sensitive analog or communication lines to minimize cross-talk.
FAQ
What is the core function of this module within the chassis?
It converts standard factory AC mains utility voltage into the stabilized DC power required by the backplane to drive local control logic.
How is the incoming AC voltage range configured on this hardware?
The module features a selectable input interface that accommodates either 85-132 VAC or 170-265 VAC utility lines.
What frequency limits does the power input stage support?
The internal transformer and filtering elements operate across a standard frequency range of 47-63 Hz.
What is the peak inrush current during initial power-up?
The module exhibits a maximum transient inrush current of up to 15 A when power is first applied.
What is the maximum output wattage at elevated temperatures?
The hardware delivers a total continuous power output maximum of 70 W when operating at temperatures up to 60 Celsius.
What are the exact physical dimensions of the module housing?
The unit dimensions measure 11.2 cm in length, 14.5 cm in depth, and 14.0 cm in height.
Does this power supply require active fan cooling?
It relies on passive convection cooling provided that specified layout clearance and ambient environment thresholds are strictly maintained.
What are the total volt-ampere and wattage ratings for input power consumption?
The maximum input power ratings are specified at 150 VA and 92 W.
What is the net unboxed weight of the standalone hardware assembly?
The individual power module has a net physical weight of exactly 1.1 Kg.
What steps are needed to secure the module against vibration?
Slide the module along the chassis guide rails until it seats firmly into the backplane, then lock the integrated mechanical fasteners tightly.
Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.
Retours et garantie
Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.
Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).
Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel
Politique de remboursement et de retour
.
Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...
Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...
Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...
Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...
Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...
Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...
Choisir une sélection entraîne un rechargement complet de la page.