1 de 3

MTL 9466-ET Commutateur Ethernet géré intrinsèquement sûr série Eaton MTL 9400

MTL 9466-ET Commutateur Ethernet géré intrinsèquement sûr série Eaton MTL 9400

Il ne reste que 7 article(s) en stock
  • Fabricant : EATON

  • N° de produit : MTL9466-ET

  • Pays d'origine :Royaume-Uni

  • Type de produit : Passerelle / Routeur Ethernet

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 450g

  • Dimensions : 42 x 115 x 105 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Product Overview

The MTL 9466-ET (MTL9466-ET) is a high-performance, Layer 2 managed Ethernet switch engineered for deployment in hazardous industrial locations. Specifically designed for mounting in Zone 1 or Division 1 areas within suitable enclosures, this 5-port module facilitates the interconnection of the MTL 9460-ET networking range. It is indispensable for critical infrastructure in oil and gas refineries, chemical processing plants, and underground mining operations where explosive atmospheres are present. By utilizing a low-latency 'store and forward' mechanism and providing broadcast storm protection, the MTL 9466-ET ensures deterministic communication and high network availability. Its ability to eliminate traditional network length limits while providing PoEx (Power over IS Ethernet) significantly reduces installation complexity and minimizes potential system downtime.

Technical Configuration (Deep Dive)

The MTL 9466-ET architecture focuses on ruggedness and intelligent data routing within hazardous zones. Unlike standard industrial hubs, this switch operates as a true point-to-point network segment controller.

  • Managed Switching Logic: While defaulting to an unmanaged 5-port switch with auto-negotiation, the onboard EEPROM allows for advanced programming via an IS RS232/TTL port. Engineers can configure VLAN support, Rate Limiting, and forced speed/duplex settings.

  • Intelligent Routing: The module features automatic address learning, aging, and migration, ensuring that data packets are directed only to the intended recipient, thereby optimizing bandwidth in sensitive IS loops.

  • PoEx Power Management: The switch acts as Power Source Equipment (PSE). By connecting an external IS power supply (such as the MTL 9491-PS) to specific terminals, the module injects power directly into the RJ45 Cat5e cables to drive downstream IS devices.

  • Protocol Support: Full compliance with IEEE 802.3 standards, including 10Base-T and 100Base-TX, with integrated MDI/MDI-X auto crossover for simplified cascading.

Technical Specifications

Feature Specification
Model MTL 9466-ET
Brand Eaton MTL
Origin United Kingdom
Port Count 5-Port 10/100 Mbps RJ45
Input Voltage 12 VDC (10 - 15.4 VDC)
Input Current 200 mA (Module only)
Operating Temp -40 to +70 deg C
Relative Humidity 5 to 95 percent RH (non-condensing)
Dimensions 75 x 100 x 116 mm
Weight 1200 g
Certification ATEX / IECEx / FM / FMC (Zone 1 / Div 1)

Technical FAQs

Q1: How does the MTL 9466-ET handle excessive network traffic from faulty devices?

A1: The module includes integrated broadcast storm protection. This hardware-level feature prevents network saturation by limiting the forwarding of excessive broadcast and multicast packets, ensuring the stability of the remaining network segments.

Q2: Can the switch settings be modified while the unit is installed in a hazardous area?

A2: Yes, the switch can be configured in the hazardous area using the MTL 9461-ET Ethernet Gateway as a host processor, or in a safe area using a standard PC via the 8-pin mini-DIN RS232 port.

Q3: What do the different LED colors on the front panel indicate?

A3: The PWR (green) indicates power status; WDG (red) flashes at 10 Hz for healthy watchdog status; FDX (red) shows Full Duplex mode; 10 ACT (yellow) and 100 ACT (green) indicate link speed and activity for each port.


Engineering & Installation Guide

  • PoEx Terminal Wiring: When utilizing PoEx functionality, inject device power into terminals 6 through 15 as required. Note that terminals 1+2 and 3+4 are linked internally for the primary 12 VDC module supply input.

  • Cable Selection: Use high-quality Cat5e shielded cable for all RJ45 connections. For long-distance spans, integrate the module with MTL fiber-optic networking components to maintain timing requirements and signal integrity.

  • Enclosure Requirements: Although the module is certified for Zone 1 / Division 1, it must be mounted in an enclosure that meets the specific Ingress Protection (IP) and impact requirements dictated by the local hazardous area certification.

Engineering Advantages

The MTL 9466-ET is built to withstand extreme environmental stress, featuring an operating temperature range of -40 to +70 deg C and high vibration resistance. Its Layer 2 "Store and Forward" technology is specifically tuned to overcome the collision detection limitations of older hubs, allowing for significantly larger and more flexible Ethernet topologies in hazardous zones. The inclusion of MIB counters via the RS232 port provides engineers with deep visibility into network health, enabling predictive maintenance before a hardware failure occurs.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

MTL 9466-ET Commutateur Ethernet géré intrinsèquement sûr série Eaton MTL 9400

正在加载 PDF,请稍候…

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Color pattern
Blanc grisâtre
Country of origin
Royaume-Uni
Power source
Alimenté par courant alternatif Alimentation DC

Customer Reviews

Be the first to write a review
0%
(0)
0%
(0)
0%
(0)
0%
(0)
0%
(0)

Produits récemment consultés

Connaissances techniques

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...

Configuration de contrôle de mouvement à axe unique avec les servomoteurs CMZ

Ce tutoriel explore la mise en service d'un système de mouvement servo à un seul axe utilisant un variateur CMZ SBD, couvrant l'installation matérielle, la mise à l'échelle de l'axe, la configuration...

Intégration du PLC Mitsubishi FX avec le variateur FR-D700 et le contrôle HMI

Ce tutoriel explique comment les automates programmables Mitsubishi FX s'intègrent avec les variateurs de fréquence FR-D700 et les panneaux HMI pour le contrôle avant/arrière des moteurs. Il couvre...