1 de 1

PLX31-EIP-MBS4 | ProSoft | Passerelle de communication série à quatre ports

PLX31-EIP-MBS4 | ProSoft | Passerelle de communication série à quatre ports

Il ne reste que 10 article(s) en stock
  • Fabricant : ProSoft

  • N° de produit : PLX31-EIP-MBS4

  • Pays d'origine :États-Unis

  • Type de produit : Passerelle de communication série à quatre ports

  • Paiement : Virement bancaire, Western Union

  • Poids : 3000g

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The PLX31-EIP-MBS4 is an industrial-grade communication gateway designed to establish bi-directional data exchange between EtherNet/IP networks and Modbus Serial protocols. By acting as a protocol converter, this module permits EtherNet/IP-enabled controllers, such as Rockwell Automation Logix processors, to seamlessly read and write data to Modbus Serial devices. The gateway features four isolated serial ports, allowing independent configuration for RS-232, RS-422, or RS-485 electrical interfaces. This flexibility enables high-density integration of field instruments, power meters, drives, and flow controllers into modern control systems.

Engineered for demanding industrial environments, this interface module supports both EtherNet/IP Class 1 I/O connections for real-time control and Class 3 messaging for diagnostic data transfer. The dynamic data mapping capabilities allow engineers to optimize throughput, ensuring minimal latency between networks.

Features

  • Four fully independent, isolated serial ports supporting RS-232, RS-422, and RS-485 configurations.
  • Supports up to 5 EtherNet/IP Class 3 server connections and 8 Class 1 I/O connections.
  • Bi-directional data mapping between EtherNet/IP and Modbus Serial networks.
  • Configurable serial parameters including baud rate, parity, stop bits, and handshaking.
  • Diagnostics and monitoring available via web-based configuration tools.
  • Wide operating temperature range suited for unconditioned control cabinets.

Applications

  • SCADA and HMI integration with legacy Modbus field devices.
  • Power distribution networks integrating Modbus RTU power meters.
  • Oil and gas flow metering system communication.
  • Water and wastewater remote telemetry integration.
  • Industrial manufacturing assembly line automation.

Technical Specifications

ParameterSpecification
Manufacturer ProSoft Technology
Part Number / Model PLX31-EIP-MBS4
Product Type EtherNet/IP to Modbus Serial Gateway
Number of Serial Ports 4 (isolated)
Serial Interface Types RS-232, RS-422, RS-485
EtherNet/IP Class 3 Connections 5
EtherNet/IP Class 1 I/O Connections 8
I/O Connection Size 248 / 248 bytes
Max Requested Packet Interval (RPI) 5 ms per connection
Nominal Input Voltage 24 VDC
Allowed Input Voltage Range 10 to 36 VDC
Current Load (Nominal) 300 mA @ 24 VDC
Current Load (Maximum) 610 mA @ 10 to 36 VDC
Operating Temperature -25 degC to 70 degC
Storage Temperature -40 degC to 80 degC
Shipping Weight 3 kg

Connections and Interfaces

Interface PortPhysical Connection TypeSupported Protocols
Ethernet Port RJ45 (10/100 Mbps) EtherNet/IP, TCP/IP
Serial Port 1 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 2 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 3 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Serial Port 4 RJ45 (RS-232/422/485) Modbus RTU / ASCII
Power Input 3-position terminal block Positive, Negative, GND

Installation Guidelines

  • Mounting: Install on standard 35mm DIN rails. Verify the locking mechanism is secure.
  • Grounding: Connect the dedicated ground terminal on the power connector directly to the panel functional ground using low-impedance copper wire.
  • Wiring: Route communication cabling (Ethernet and Serial) away from high-voltage AC lines to prevent electromagnetic interference.
  • Clearance: Maintain at least 50mm of clearance at the top and bottom of the module to support proper convective cooling.

Compliance and Certifications

  • CE Mark
  • UL/cUL Class I, Division 2
  • ATEX Zone 2
Loading product navigation…

What protocols does the ProSoft PLX31-EIP-MBS4 gateway bridge?

The PLX31-EIP-MBS4 bridges devices on an EtherNet/IP network with devices on Modbus Serial (RTU or ASCII) networks.

Can the serial ports be configured independently?

Yes, all four serial ports are isolated and can be individually configured for RS-232, RS-422, or RS-485 physical layer communication.

What are the power requirements for this gateway?

The module requires a nominal 24 VDC power supply, but supports an input range of 10 to 36 VDC.

How many Class 1 and Class 3 connections does it support?

It supports up to 5 Class 3 Server connections and up to 8 Class 1 I/O connections.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
États-Unis

Produits récemment consultés

Connaissances techniques

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...