8965370000 | Weidmuller | Amplificateurs d'interrupteur isolant ACT20X-2HDI-2SDO-RNO-S

8965370000 | Weidmuller | Amplificateurs d'interrupteur isolant ACT20X-2HDI-2SDO-RNO-S

Il ne reste que 10 article(s) en stock
  • Fabricant : Weidmuller

  • N° de produit : 8965370000

  • Pays d'origine :Allemagne

  • Type de produit : Amplificateurs à commutation isolante

  • Paiement : Virement bancaire, Western Union

  • Poids : 190g

  • Dimensions : 117.2 mm x 22.5 mm x 113.6 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Weidmuller 8965370000 ACT20X-2HDI-2SDO-RNO-S Isolating Switch Amplifiers

Description

Designed for intrinsic safety applications, the Weidmuller 8965370000 functions as a highly reliable isolating switch amplifier to transmit digital signals from hazardous areas (Zone 0, 1, 2) to safe areas. This 2-channel module is engineered to process signals from NAMUR sensors or mechanical contacts located in explosive atmospheres, providing complete galvanic isolation between the input, output, power supply, and alarm contacts.

The ACT20X-2HDI-2SDO-RNO-S features integrated line fault detection (LFD) to monitor the input circuits for wire breaks or short circuits. In the event of a fault, the device triggers an alarm relay, ensuring rapid diagnostics and minimizing system downtime. Configuration is easily managed via standard FDT/DTM software, allowing precise customization of operational parameters to match specific process requirements.

Features

  • Dual-channel signal isolation and transmission from Ex to non-Ex zones.
  • Intrinsically safe input circuits compatible with NAMUR sensors and mechanical switches.
  • Two normally open (NO) relay outputs for reliable signal switching.
  • Comprehensive line fault detection (LFD) for short-circuit and wire-break monitoring.
  • FDT/DTM software configuration for flexible parameter adjustment.
  • Complete galvanic isolation between input, output, power supply, and alarm contacts.
  • Compact 22.5 mm DIN-rail mountable housing to optimize cabinet space.

Applications

  • Chemical and petrochemical processing plants.
  • Oil and gas extraction, refining, and distribution facilities.
  • Water and wastewater treatment automation.
  • Hazardous area digital signal isolation (Zone 0, 1, 2, and Class I Div 1/2).

Technical Specifications

Manufacturer Weidmuller
Part Number / Model 8965370000 (ACT20X-2HDI-2SDO-RNO-S)
Product Type Isolating Switch Amplifier
Number of Channels 2
Input Type NAMUR sensor (DIN EN 60947-5-6) or switch contact
NAMUR Supply 8 V DC / 8 mA
Output Type Relay (1 NO contact per channel)
Nominal Switching Voltage 125 V AC / 110 V DC (safe area)
Continuous Current 0.5 A AC / 0.3 A DC
Supply Voltage 19.2 to 31.2 V DC
Power Consumption ≤ 1.9 W
Configuration FDT/DTM software
Connection Type Screw connection
Protection Degree IP20
Operating Humidity 0 to 95% (no condensation)
Dimensions (H x W x D) 117.2 mm x 22.5 mm x 113.6 mm
Weight 0.190 kg

Connections and Interfaces

Terminal Pin Function
Inputs (Hazardous Area) Channel 1 & Channel 2 NAMUR / Switch Contacts
Outputs (Safe Area) Channel 1 & Channel 2 Relay NO Contacts
Power Supply 24 V DC (+ / -)
Alarm Output Fault signaling relay contact

Installation Guidelines

  • Mounting: Mount vertically on a standard TS 35 DIN rail.
  • Wiring: Ensure strict physical separation between intrinsically safe (Ex i) input wiring and non-intrinsically safe output/power wiring. Maintain a minimum distance of 50 mm between the terminal groups.
  • Grounding: Connect the DIN rail to the local functional earth ground to ensure proper shielding and noise immunity.
  • Ventilation: Provide adequate clearance above and below the module to prevent heat buildup inside the control cabinet.

Compliance and Certifications

  • CE
  • ATEX
  • IECEx
  • UL Class I, Division 2 / Zone 2
Loading product navigation…

What is the primary function of the Weidmuller 8965370000?

It is a 2-channel isolating switch amplifier designed to safely transmit digital signals (such as NAMUR sensors or mechanical contacts) from hazardous Ex zones to safe areas.

How is the ACT20X-2HDI-2SDO-RNO-S configured?

The module is configured using standard FDT/DTM software, allowing precise adjustment of input types, line fault detection, and output behavior.

What type of outputs does this module provide?

It features two normally open (NO) relay outputs, along with an integrated alarm relay for system status and fault signaling.

Does the 8965370000 support line fault detection?

Yes, it includes built-in line fault detection (LFD) to monitor input circuits for short circuits and wire breaks.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d’origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître les conditions d’éligibilité complètes, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Allemagne

Produits récemment consultés

Connaissances techniques

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l'intégration IDS/IPS...

Guide des préhenseurs robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés du gecko et des pinces souples de qualité alimentaire aux outils d'entrepôt...

Retour en arrière : comment les premiers moteurs électriques ont transformé l'exploitation minière souterraine

Des compresseurs à courant continu entraînés par corde aux wagonnets de mine alimentés par batterie, les premières opérations minières ont marqué un tournant dans l’électrification industrielle. Cet...

Factory I/O : un outil moderne de simulation PLC pour la formation à l'automatisation industrielle

Factory I/O révolutionne l'enseignement des automates programmables industriels (API) en proposant des simulations industrielles 3D immersives pour les étudiants, les ingénieurs et les équipes de...

Programmation des cycles de mouvement à axe unique sur un servo-variateur CMZ

Ce tutoriel examine comment la fonctionnalité PLC intégrée dans un servo-variateur CMZ SBD peut exécuter des programmes de mouvement autonomes, y compris la logique de référencement, le contrôle de...