1 of 3

Module d'entrée analogique Yokogawa SAI143-S33

Module d'entrée analogique Yokogawa SAI143-S33

Il ne reste que 8 article(s) en stock
  • Fabricant : Yokogawa

  • N° de produit : SAI143-S33

  • Pays d'origine :Japon

  • Type de produit : Module d'Entrée Analogique

  • Code-barres : 8537101190

  • Paiement : Virement bancaire, Western Union

  • Poids : 340g

  • Dimensions : 32.8 mm x 130 mm x 107.5 mm

  • Port d'expédition : Xiamen

  • Garantie : 12 mois

Quantité
Voir les détails complets

Description

The Yokogawa SAI143-S33 is a high-reliability current input module designed for mounting on the safety node unit and safety control unit within the ProSafe-RS safety instrumented system. This module plays a critical role in safety functions by inputting 4 to 20 mA signals from field instruments directly into the Safety Control Station (SCS). It supports dual-redundant configurations to achieve enhanced system availability and fault tolerance. The SAI143-S33 features standard individual channel configuration pins for 2-wire or 4-wire transmitters and provides module isolation for its 16 processing channels.

Features

  • Dual Redundancy: Supports full dual-redundant configuration to eliminate single points of failure in safety-critical applications.
  • Flexible Sensor Hookup: Individual channel setting via pins to accommodate both 2-wire and 4-wire field transmitter arrangements.
  • Simultaneous Power Management: Built-in transmitter power supply ON/OFF function across all 16 channels simultaneously, facilitating alarm resets for Fire and Gas devices.
  • Robust Isolation: Delivers module-level galvanic isolation protecting internal system electronics from hazardous field transients.

Applications

  • Safety Instrumented Systems (SIS) 
  • Emergency Shutdown Systems (ESD)
  • Fire and Gas (F&G) System integration and device resetting 
  • Process industry safety monitoring and critical current loop sourcing 

Ordering Information

Model Suffix Codes Description
SAI143   Analog Input Module (4 to 20 mA, 16 channels, module isolation) 
  -S Standard type 
  3 For pressure clamp terminal block or MIL cable with no explosion protection
3 With ISA Standard G3 and temperature (-20 to 70 degC) 

Technical Specifications

Item Specifications
Manufacturer Yokogawa Electric Corporation 
Model SAI143-S33 
Number of Input Channels 16 channels, module isolation 
Rated Input Range 4 to 20 mA 
Permissible Input Range 0 to 25 mA 
Input Impedance (Power-ON) 250 Ohm + Voltage drop in the input protection circuit inside the module / Current value 
Input Impedance (Power-OFF) 500 Ohm minimum 
Maximum Voltage Drop 0.45 V (in the input protection circuit) 
Rated Accuracy ±16 uA (Input range 1 to 23 mA for Style S3) 
Data Update Frequency 40 ms 
Temperature Drift ±16 uA/10 degC 
Transmitter Power Supply 16.15 V minimum (at 20 mA), 26.4 V maximum (at 0 mA) 
Output Current Limit 25 mA 
Withstand Voltage 1.5 kV AC between input signal and system for 1 minute 
Maximum Current Consumption 5 V system: 320 mA, 24 V system: 550 mA 
Ambient Temperature -20 to 70 degC 
Environmental Code ISA Standard G3 
Weight Approx. 0.34 kg (For pressure clamp terminal block or MIL cable) 
Dimensions (W x H x D) 32.8 mm x 130 mm x 107.5 mm (For pressure clamp and MIL cable) 

Installation Guidelines

  • Module Siting: Mount the current input module onto a compatible safety node unit or safety control unit chassis.
  • Redundancy Setup: When implementing dual-redundant pairs, order an additional tracking module with identical technical specifications but without specific optional suffix accessories.
  • Safety Isolation Barriers: Do not connect Zener barriers directly to this hardware. Utilize an approved isolation barrier when deploying an intrinsically safe instrumented loop.
  • False Insertion Prevention: When deploying option /PRP, utilize the specified matching field signaling cable variant equipped with the corresponding option /SAI143 to ensure functional physical key alignment.

Compliance and Certifications

  • ISA Standard G3: Certified for installation within corrosive industrial environments meeting the G3 severity specifications.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Module d'entrée analogique Yokogawa SAI143-S33

Can Zener barriers be connected directly to the module?

No, Zener barriers cannot be connected to this module. An isolation barrier must be used when an intrinsically safe instrumented system is required.

What is the purpose of the transmitter power supply ON/OFF function?

This function allows the module to turn off the transmitter power supplied to all 16 channels simultaneously under a 2-wire setting, which enables resetting the alarm state of Fire and Gas devices.

How is the 2-wire or 4-wire mode configured on the module?

The 2-wire or 4-wire operational mode is set individually for each channel using dedicated physical setting pins on the module.

Expédition express mondiale

  • Livraison standard : 4 à 6 jours ouvrables via DHL, FedEx et UPS.
  • Expédition express : Expédition le jour même pour les commandes en stock passées avant 14h00 (GMT+8).
  • Couverture mondiale : Service dans plus de 150 pays, avec livraison rapide en Arabie Saoudite et aux Émirats arabes unis.

Retours et garantie

  • Garantie de 30 jours : Retours acceptés pour les produits en stock dans leur emballage d'origine scellé en usine.
  • Garantie de 12 mois : Chaque composant industriel est couvert par notre garantie technique professionnelle.

Les commandes sont traitées et livrées du lundi au vendredi (hors jours fériés).


Pour connaître l'éligibilité complète, les frais de restockage et les détails des retours internationaux, veuillez consulter notre site officiel Politique de remboursement et de retour .

TECHNICAL SPECIFICATIONS

Country of origin
Japon

Produits récemment consultés

Connaissances techniques

Actionneurs électriques conçus pour remplacer les fluides : tutoriel pratique

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Opérations mathématiques avec OpenPLC pour les applications d'automatisation industrielle

Cet article explique comment les systèmes PLC réalisent des opérations mathématiques de base telles que l'addition, la soustraction, la multiplication, la division, le modulo et l'exponentiation dans...

Logique booléenne avancée avec la programmation FBD PLC : applications industrielles pratiques au-delà de la logique de base

L'article explique plusieurs fonctions avancées de la logique booléenne utilisées en programmation d'automates programmables industriels (API) au-delà des opérations de base ET, OU et NON. Il aborde...

Logique booléenne en programmation PLC : comprendre les portes logiques FBD

La logique booléenne est la base de tout programme PLC. Des commandes machines simples aux systèmes d'automatisation industrielle complexes, les portes logiques déterminent comment les contrôleurs...

Guide approfondi sur les pare-feux industriels et la segmentation des réseaux OT

Les pare-feux industriels jouent un rôle crucial dans la cybersécurité OT, protégeant les réseaux PLC, DCS et SCADA grâce à la segmentation, au contrôle des entrées/sorties et à l’intégration IDS/IPS...

Guide des pinces robotiques : de la manipulation délicate à l'automatisation lourde

Les pinces robotiques modernes évoluent au-delà des mâchoires mécaniques traditionnelles. Des systèmes adhésifs inspirés des geckos aux pinces souples de qualité alimentaire, en passant par des...