Only 10 item(s) left in stock
  • Manufacturer: Bently Nevada

  • Product No.: 149986-01ÿ+149992-01

  • Country of origin:Egyesült Államok

  • Product Type: Relay Control Module

  • Payment: T/T, Western Union

  • Weight: 700g

  • Dimensions: 241 mm x 24.4 mm x 242 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Overview

The 149986-01 + 149992-01 (149986-01/149992-01) combination constitutes the complete 16-Channel Relay Module assembly for the Bently Nevada 3500 Series Machinery Protection System. This full-height solution consists of the 149986-01 Main Control Module and the 149992-01 Output Termination Module. Designed to provide high-density alarming capabilities, this system allows for 16 independent relay outputs that can be programmed with complex "voting logic" via the 3500 Rack Configuration Software. By utilizing AND/OR logic gates, plant engineers can trigger protective actions based on Alert, Danger, or Not-OK statuses from any monitor channel within the rack. This modular relay system is a critical component for automated machinery shutdown, protecting multi-million dollar assets in power plants, refineries, and offshore platforms from catastrophic mechanical failure.

Technical Configuration

The 3500/33 system is designed for maximum flexibility and reliability in industrial control:

  • Logic Integration: Each of the 16 channels features independent Alarm Drive Logic, capable of processing individual measured variables or combinations of monitor channels.

  • Operational Modes: Relays are organized into four groups of four channels. Each group is switch-selectable for Normally De-energized (ND) or Normally Energized (NE) "Failsafe" operation.

  • Standard Contact Construction: Features epoxy-sealed Single-Pole Double-Throw (SPDT) relays with built-in 250 Vrms arc suppressors to ensure long-term contact integrity.

  • Visual Diagnostics: The front panel includes high-visibility LEDs for module "OK" status, TX/RX communication flashes, and individual Channel Alarm indicators for real-time troubleshooting.

Technical Specifications

Parameter Specification Details
Brand Bently Nevada
Model Number 149986-01 (Control) + 149992-01 (Output)
Series 3500/33 Machinery Protection System
Relay Type 16-Channel SPDT (Single-Pole Double-Throw)
Power Consumption 5.8 watts typical
Max Switched Current 5 A (Resistive Load)
Max Switched Voltage (AC) 250 Vac
Max Switched Voltage (DC) 125 Vdc (Standard) / 30 Vdc (Failsafe/Haz)
Environmental Sealing Epoxy-sealed Relays
Operating Dimensions 241 mm x 24.4 mm x 242 mm
Main Module Weight 0.7 kg (1.6 lb)

Technical FAQs

Can I install the 16-channel relay module in any rack slot?

The 3500/33 can be placed in any of the slots in the 3500 rack, provided they are to the right of the Transient Data Interface (TDI) Module.

What are the software requirements for this specific hardware?

To utilize the 149986-01, your system must run 3500 Rack Configuration Software version 3.3 or later, and Data Acquisition Software version 2.40 or later.

Why is the voltage rating lower for SIL or Hazardous Area systems?

In Failsafe or Multiple Approval (-02) systems, the maximum switched voltage is de-rated to 30 Vdc/Vrms to comply with ATEX and North American Zone 2 spacing requirements and 61010-1 safety type tests.


Engineering & Installation Guide

Contact Load Management

For standard silver contacts used in the 149986-01, the minimum switched load is 100 mA @ 5 Vdc. If your control circuit operates at lower currents (e.g., interfacing with high-impedance digital inputs), ensure you are using the Low Current (gold-plated) variant to prevent contact oxidation and intermittent signaling. For gold-plated contacts, do not exceed 5 mA to avoid damaging the plating.

Arc Suppression and Inductive Loads

While the module includes standard 250 Vrms arc suppressors, we strongly recommend installing external flyback diodes (for DC) or varistors (for AC) when driving high-inductance solenoid valves. This reduces EMI and extends the relay contact life beyond the rated 10,000 cycles.

System Compatibility and Safety

If this module is integrated into a Functional Safety (SIL) loop, you must strictly adhere to the restricted voltage limits specified in the safety certificate. Exceeding 30 Vdc in a hazardous area application violates the equipment's certification and may create a spark hazard. Always verify the "Normally Energized" vs "Normally De-energized" switch positions before powering the rack to prevent accidental machine trips during commissioning.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

149986-01 + 149992-01 Bently Nevada 3500/33 Spare 16-Channel Relay Control Module

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Ezüst
Country of origin
Egyesült Államok
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...