1 / 1

ABB ACS580-01-073A-4 3AUA0000080499 LV AC General Purpose Drive

ABB ACS580-01-073A-4 3AUA0000080499 LV AC General Purpose Drive

Only 5 item(s) left in stock
  • Manufacturer: ABB

  • Product No.: ACS580-01-073A-4

  • Country of origin:Svédország

  • Product Type: LV AC General Purpose Wall-Mounted Drive

  • Barcode: 85044086

  • Payment: T/T, Western Union

  • Weight: 20000g

  • Dimensions: 203 mm x 636 mm x 257 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Product Overview

The ACS580-01-073A-4 is a wall-mounted low voltage AC general purpose drive belonging to the ABB ACS580 series. This all-compatible drive is engineered to simplify process management for a wide range of variable and constant torque applications. It is primarily used to control pumps, fans, conveyors, compressors, and mixers across various industries, including food and beverage, agriculture, and material handling.

This unit operates on a 380 to 480 V three-phase supply, delivering a nominal output current of 73 A and a power rating of 37 kW under normal use. The ACS580-01 architecture incorporates essential features as standard, including an integrated EMC filter, a Modbus RTU interface, and functional safety features like Safe Torque Off (STO). The R4 frame size drive comes with an IP21 enclosure rating, suitable for indoor wall-mounted installations where efficiency and ease of commissioning are prioritized.

Technical Configuration

Attribute Details
Brand ABB
Model ACS580-01-073A-4
Product ID 3AUA0000080499
Product Type Frequency Converters (LV AC Drives)
Series ACS580 Series
Frame Size R4
Phase Number 3-Phase
Input Voltage (Uin) 380 ... 480 V
Nominal Output Current (In) 73 A
Nominal Output Power (Pn) 37 kW
Heavy-Duty Output Power (PHD) 30.0 kW
Protection Rating IP21 (NEMA Type 1)
Efficiency Class IE2
Altitude 4000 m (with derating above 1000m)
Communication Protocols Modbus RTU (Standard); Optional: Profibus, Profinet, EtherNet/IP
Hardware Interfaces USB x1, RS-485 x1, Analog I/O x4, Digital I/O x9
Weight 20 kg (44.09 lb)
Dimensions (W x H x D) 203 mm x 636 mm x 257 mm

Ordering Information

Industrial procurement and replacement should reference the following unique identifiers to ensure system compatibility.

Identification Value
Product ID 3AUA0000080499
ABB Type Designation ACS580-01-073A-4
EAN Number 6438177305552
Customs Tariff Number 85044087
Minimum Order Quantity 1 piece

Engineering & Installation Guide

Mounting and Cooling:

The ACS580-01-073A-4 R4 frame requires vertical wall mounting on a non-flammable surface. Ensure a minimum clearance of 200 mm above and below the unit for adequate airflow. The internal cooling fan generates approximately 70 dB(A) of sound; cabinet ventilation must be sized to handle the 858 W power consumption loss at full load.

Grounding and EMC:

To comply with EMC Category C2, use symmetrical shielded motor cables. Ensure 360-degree grounding at the cable entries using the provided metallic clamps. The drive includes an internal EMC filter as standard; however, for IT (ungrounded) systems, the internal EMC filter and varistors must be disconnected before power-up.

I/O and Control Wiring:

Separate control cables from power and motor cables. Use twisted-pair shielded cables for analog signals and RS-485 communication. The drive supports Safe Torque Off (STO) SIL3/PLe; if STO is not used, jumpers must be maintained between the STO terminals (OUT1 to IN1/IN2) for operation.

Hardware FAQ

Q: What is the maximum altitude for the ACS580-01-073A-4 without derating?

A: The drive is rated for up to 4000 m. However, current derating of 1% for every 100 m is required for altitudes above 1000 m. Above 2000 m, the voltage rating of the relay outputs may decrease.

Q: Can this drive be used for heavy-duty applications?

A: Yes. While the normal use rating is 37 kW (73 A), the heavy-duty (IHD) rating is 30 kW (61 A). Ensure the motor FLA (Full Load Amps) does not exceed 61 A for constant torque, high-overload applications.

Q: What should be checked if the drive shows a "Safe Torque Off" fault?

A: Inspect the STO circuit wiring. Both STO channels must be closed for the drive to start. If using an external safety relay, verify the relay contact health and the 24V DC supply integrity from the control unit.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Szürkésfehér
Country of origin
Svédország

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...