The 1768-ENBT is a CompactLogix EtherNet/IP Communication Module developed by Allen-Bradley to provide dedicated Ethernet networking capabilities for 1768 control systems. This module establishes reliable data transmission links across an industrial network, enabling seamless connectivity with multiple Logix5000 controllers, supervisory computers, and auxiliary automation equipment. It processes network traffic over a integrated communication interface while managing local status via an alphanumeric display and built-in diagnostic indicators. Designed as an open-type component, it installs directly within a synchronized hardware stack consisting of a 1768 controller and compatible power supplies to optimize throughput and minimize communication downtime.

Features

  • Provides automated data management over EtherNet/IP networks to reduce packet collisions and sustain optimal bandwidth.
  • Features an integrated alphanumeric display and three bi-color diagnostic status indicators (NET, Link, and OK) for rapid local troubleshooting.
  • Supports high-speed data transmission over standard Category 5 or Category 5e cabling using a rugged RJ45 connector interface.
  • Implements reliable electrical protection with a continuous functional insulation rating of 30V between the Ethernet network and internal system circuits.
  • Interfaces directly with specialized 1768 CompactLogix system components and supports flexible expansion using combined 1769-series I/O modules.

Applications

  • Distributed industrial automation and manufacturing plant network management.
  • Inter-controller data synchronization across multiple Logix5000 systems.
  • SCADA network routing and remote control system interface integration.

Technical Specifications

Parameter Specification
Backplane Current 834 mA at 5.2V DC
Power Consumption 4.34 W
Power Dissipation 4.38 W
Isolation Voltage 30V (continuous-voltage rating), Functional Insulation Type, Ethernet network to system (Type tested at 710V DC for 60 s)
Wire Size RJ45 connector according to IEC 60603-7, 2 or 4 pair Category 5e minimum cable according to TIA 568-B.1 or Category 5 cable according to ISO/IEC 24702
Wiring Category 2 - on communication ports
North American Temp Code T4A
IEC Temp Code T4
Mounting Screw Torque 1.16 N.m (10 lb.in) using M4 or #8 screws
Dimensions (HxWxD), Approx. 132 x 56.7 x 105.1 mm (5.20 x 2.23 x 4.12 in.)
Weight, Approx. 0.213 kg (7.5 oz)
Temperature, Operating 0...60 degC (32...140 degF)
Temperature, Nonoperating -40...85 degC (-40...185 degF)
Relative Humidity 5...95% noncondensing
Vibration 5 g @ 10...500 Hz
Operating Shock 30 g
Nonoperating Shock 50 g
Emissions CISPR 11 Group 1, Class A
Enclosure Type Rating None (open-style)

Connections/Interfaces

Connector Pin Function
Pin 1 TD+ (Transmit Data +)
Pin 2 TD- (Transmit Data -)
Pin 3 RD+ (Receive Data +)
Pin 4 NC (No Connection)
Pin 5 NC (No Connection)
Pin 6 RD- (Receive Data -)
Pin 7 NC (No Connection)
Pin 8 NC (No Connection)

Installation Guidelines

  • Plan for a minimum hardware clearance of 105 mm (4 in.) at the top and bottom, and 90 mm (3.54 in.) on the sides from enclosure walls, wireways, and adjacent machinery.
  • Ensure the system is grounded through the DIN rail to the chassis ground by utilizing zinc-plated yellow-chromate steel DIN rail; avoid aluminum or plastic rails which can oxidize and cause poor conductivity.
  • Secure the mounting DIN rail to the surface approximately every 200 mm (7.87 in.) and install appropriate end-anchors to hold modules firmly.
  • If choosing panel mounting instead of DIN rail installation, mark pilot holes using the hardware as a template, drill holes for M4 or #8 screws, and tighten to 1.16 N.m (10 lb.in) of torque. Do not use screws and DIN rail concurrently.
  • Connect the network interface cable to a 100 MB Ethernet switch rather than a shared hub to increase network bandwidth and reduce lost packets.
  • Never connect or disconnect network communication cables while power is actively applied, as an electrical arc can occur and present an explosion hazard in certified environments.
  • Always wait for all diagnostic status lights on the power supply and controller to turn completely off before disconnecting any system module to allow the processor sufficient time to finish writing project parameters to non-volatile memory.
  • Mitigate static risks by touching a grounded object, wearing an approved grounding wriststrap, and strictly avoiding contact with component board pins, connectors, or internal circuit elements.

Compliance and Certifications

  • c-UL-us Listed Industrial Control Equipment, Certified for US and Canada (UL File E65584)
  • c-UL-us Listed for Class I, Division 2 Group A, B, C, D Hazardous Locations, Certified for US and Canada (UL File E194810)
  • CE Certified (European Union 2004/108/EC EMC Directive, compliant with EN 61326-1, EN 61000-6-2, EN 61000-6-4, and EN 61131-2)
  • C-Tick Compliant (Australian Radiocommunications Act, compliant with AS/NZS CISPR 11)
  • Ex Certified (European Union 94/9/EC ATEX Directive, compliant with EN 60079-15 and EN 60079-0; II 3 G Ex nA IIC T4)
  • EtherNet/IP ODVA Conformance Tested

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Allen-Bradley 1768-ENBT CompactLogix EtherNet/IP Communication Module

What does a flashing red status on the NET indicator signify?

A flashing red network (NET) indicator indicates that one or more of the established connections in which the communication module is acting as the target device have timed out.

Why must installers wait for all status lights to turn off before separating the hardware?

When system power is switched off, the main controller writes its active project data to non-volatile memory. Separating the modules before all status lights turn off interrupts this process, resulting in the unrecoverable loss of the control program.

What happens if the OK status indicator exhibits a flashing red and green pattern?

A flashing red and green pattern on the OK indicator indicates that the communication module is actively executing its standard power-up self-test routines.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Szürkésfehér
Country of origin
Egyesült Államok
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...