1 / 1

B&R X20SC2212 X20 System Safe Digital Mixed I/O Module

B&R X20SC2212 X20 System Safe Digital Mixed I/O Module

Only 10 item(s) left in stock
  • Manufacturer: B&R

  • Product No.: X20SC2212

  • Country of origin:Egyesült Államok

  • Product Type: Digital Mixed Modules

  • Payment: T/T, Western Union

  • Weight: 2000g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

The B&R X20SC2212, part number X20SC2212, is a safety-oriented digital mixed I/O module designed for integration within the X20 system backplane communication architecture to execute fail-safe control logic. The electronic module incorporates 6 safe type A digital inputs paired with 6 dedicated pulse outputs for cross-fault detection monitoring, alongside 2 safe type B1 digital outputs rated at 24 VDC and 0.5 A. Actuation and switching behavior for the safety outputs utilize an Output Signal Switching Device (OSSD) design with a diagnostic test pulse width of less than 500 µs to guarantee rapid response times during safety demands. Power distribution across the internal circuitry runs on a nominal 24 VDC bus with integrated reverse polarity protection to prevent component damage from improper electrical installation.

Hardware Specifications

  • Module Type: Safety-related digital mixed I/O module
  • Input Configuration: 6 safe type A digital inputs
  • Output Configuration: 2 safe type B1 digital outputs, 6 pulse outputs
  • Nominal Voltage: 24 VDC
  • Permissible Voltage Range: 20.4 to 28.8 VDC (24 VDC -15% / +20%)
  • Digital Output Current Rating: 0.5 A per channel
  • OSSD Pulse Width: <500 µs
  • Integrated Protection: Reverse polarity protection
  • Operating Humidity Range: 5 to 95%, non-condensing
  • Storage Humidity Range: 5 to 95%, non-condensing
  • Transport Humidity Range: 5 to 95%, non-condensing
  • Shipping Weight: 2 kg

Engineering Notes

  • Cyclic data exchange across the X20 backplane handles the safety I/O image transmission via the openSAFETY protocol to ensure deterministic communication timings.
  • The 6 pulse outputs emit specific test patterns that feed back into the 6 safe type A digital inputs to continuously verify physical line integrity and diagnose short circuits across channels or to external potential lines.
  • Safe type B1 digital outputs execute internal dual-channel monitoring sequences to detect component failures, ensuring the module transitions to a defined safe state if an unrecoverable fault occurs.
  • The operational power window is strictly limited to 20.4 to 28.8 VDC; any fluctuation outside these parameters causes an undervoltage or overvoltage diagnostic fault register entry, disabling the safety outputs.

Field Guidelines

  • Backplane Communication Shielding: Ensure the X20 bus base components are securely snapped together on the DIN rail to maintain low-impedance grounding across the local backplane communication segments.
  • Cable Routing and Separation: Route safety sensor and actuator wiring cables in separate wire ducts from high-current AC or variable speed drive conductors to minimize electromagnetic interference on the OSSD pulse lines.
  • Shield Grounding: Ground all shielded cables used for remote safety sensors directly at the entry point of the control panel enclosure using a low-impedance grounding rail.
  • Connector Insulation and Termination: Ensure all field wiring connections utilize correct cross-section conductors and crimped wire ferrules to secure consistent contact force within the terminal block layout.

Technical & Procurement FAQ

Question: Is the X20SC2212 safety module hot-swappable within an active X20 I/O chassis segment?

Answer: Yes, the three-part modular design of the X20 system allows the electronic module to be hot-swappable without disconnecting the terminal block wiring or breaking the backplane communication loop of adjacent modules.

Question: What firmware matching requirements apply when replacing a legacy hardware revision of this module?

Answer: Firmware compatibility is managed through the automation software platform, which cross-references the safety configuration checksum to ensure complete functional matching before allowing cyclic data exchange to resume.

Question: What physical contents are included out-of-the-box with the specific part number X20SC2212?

Answer: The package contains the brand new original stock electronic module itself; the matching X20 bus base and X20 front terminal block must be ordered as separate accessories to complete the mechanical installation.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Color pattern
Sárga
Country of origin
Egyesült Államok
Power source
DC áram

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...