Beckhoff CX1100-0930 CX Series UPS Module

Beckhoff CX1100-0930 CX Series UPS Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: CX1100-0930

  • Country of origin:Németország

  • Product Type: UPS Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 95 mm x 100 mm x 91 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Integrating directly into the modular PC/104 bus architecture, the Beckhoff CX1100-0930 provides highly reliable, capacitive-based uninterruptible power supply capabilities for CX series Embedded PCs. This module is engineered to bridge short-term voltage fluctuations and secure volatile operational data by initiating a controlled shutdown sequence during primary power failures. By employing capacitive storage technology, it offers a maintenance-free alternative to traditional battery-backed systems, operating efficiently without risk of degradation or chemical leakage in harsh thermal environments.

Features

  • Capacitive Storage Medium: Features a 40 As capacity that eliminates regular battery maintenance intervals and shelf-life concerns.
  • Adjustable Retention Time: Provides load-dependent holdup durations that can be fully customized to meet specific system requirements.
  • Local Diagnostics indicators: Three integrated LEDs provide real-time status feedback for 24 V DC input, 24 V DC output, and capacitive charge state.
  • Embedded Bus Interface: Communicates directly via a high-speed, 16-bit ISA bus conforming to the standard PC/104 hardware layout.
  • Industrial Protection: IP20-rated housing built to resist severe industrial vibration and shock according to European standards.

Applications

  • Securing persistent memory (NOVRAM writing operations) during sudden primary power interruptions.
  • Enabling orderly, controlled OS shutdowns for Windows CE or Windows Embedded systems.
  • Protecting localized processing nodes in networks prone to voltage sags and grid fluctuations.

Technical Specifications

Parameter Specification
Manufacturer Beckhoff
Model / Article Number CX1100-0930
Input Voltage 24 V DC (-15% / +20%)
Storage Technology Capacitive
Capacity 40 As (Ampere-seconds)
Max. Output Current 2.0 A (at 24 V DC)
Charging Current Max. 4.0 A
Retention Time Adjustable, load-dependent
CPU Bus Interface 16-bit ISA (PC/104 standard)
Max. Power Loss 2.0 W
Diagnostic Displays LEDs for 24 V DC Input, 24 V DC Output, and Charge
Protection Rating IP20
Operating Temperature 0 to 55 degC
Storage Temperature -25 to 85 degC
Relative Humidity 95%, non-condensing
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Dimensions (W x H x D) 95 mm x 100 mm x 91 mm
Net Weight 650 g
Shipping Weight (Calculated) 2.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The CX1100-0930 is mechanically and electrically dedicated to the legacy CX1000 and CX1020 Embedded PC systems. If replacing an older module or a battery-backed variant (such as the CX1100-0900 series), confirm that your operating system image contains the necessary registry settings to interact with the 16-bit ISA bus address allocation. This module will not directly interface with newer CX2000 systems using PCI Express-based system interfaces.

Application Pitfalls & Engineering Notes

Because this module utilizes capacitive storage, the 40 As total energy capacity is highly dependent on the total active current draw of the CPU stack. High processing loads or extensive connected I/O terminals during a power-fail transition will drastically shorten the retention window. System integrators must design efficient, non-blocking data-dump routines in TwinCAT to write persistent data (NOVRAM) to the boot media immediately upon detecting a mains failure signal.

Commissioning & Wiring Tips

During initial commissioning, verify that the 24 V DC power supply is sized to handle the maximum charging current overhead of 4.0 A. If the primary supply exhibits a voltage sag below 20.4 V DC (the lower limit of the -15% tolerance) during the module's charging phase, the system may initiate an unintentional low-voltage shutdown sequence. Check that the "Charge" LED switches from flashing (charging active) to solid green (fully charged) within the boot-up timeline.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all 24 V DC system power before executing assembly or disassembly. Capacitive units retain an electrical charge even after primary power disconnection. Allow a minimum of three minutes for internal energy dissipation before handling the physical bus connectors or dismantling the PC/104 block.

1

Align the CX1100-0930 interface with the adjoining CX series module, ensuring the 16-bit ISA (PC/104) male and female pin connectors match precisely without offset.

2

Slide the module onto the standard DIN rail until the locking latch clicks firmly, and secure the module stack together using the mechanical side-locking mechanism.

3

Connect the 24 V DC primary supply cables to the terminals, verifying polarity, and ensure a low-impedance connection to the central functional earth terminal.

4

Energize the power source and verify that the "Input" and "Charge" LEDs illuminate, indicating active voltage input and ongoing capacitive energy buffering.

What is the primary operational advantage of the capacitive storage in the CX1100-0930?

Unlike traditional battery backup units, capacitive storage is maintenance-free, has a significantly longer operational lifespan, works across wider thermal ranges without degradation, and avoids hazardous leakage risks.

Does this module require software drivers to operate under TwinCAT?

Yes. Proper shutdown orchestration requires the installation and configuration of the Beckhoff UPS driver on the target operating system (e.g., Windows CE or Windows Embedded) connected via the PC/104 bus.

How long can the CX1100-0930 maintain power to the CPU?

The holdup duration is load-dependent. With a total capacity of 40 As (Ampere-seconds) and a maximum output current of 2.0 A, the actual backup window varies based on the current consumption of the active CPU and connected modules.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Németország

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...