1 / 1

BECKHOFF EP2816-0010 EtherCAT Box 16-Channel Digital Output Module

BECKHOFF EP2816-0010 EtherCAT Box 16-Channel Digital Output Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: EP2816-0010

  • Country of origin:Németország

  • Product Type: EtherCAT I/O Modules

  • Payment: T/T, Western Union

  • Weight: 165g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Designed for decentralized automation tasks requiring dense digital output distribution directly in the field, the Beckhoff EP2816-0010 EtherCAT Box provides 16 digital outputs in a robust, space-saving enclosure. This IP65/66/67-rated module connects binary control signals from the EtherCAT network directly to actuators and devices, eliminating the need for protective control cabinets and minimizing complex field cabling.

Featuring two 9-pin D-sub socket connections, this module is specifically optimized for direct, hassle-free interfaces with multi-pin connector valve terminals and pneumatic manifold systems. The outputs support ohmic, inductive, and lamp loads with integrated short-circuit protection and electrical isolation up to 500 V, making it highly reliable in demanding manufacturing and process environments.

Features

  • 16 digital output channels in a highly compact, direct-to-field mountable housing.
  • Equipped with two 9-pin D-sub socket connectors tailored for multi-pin valve manifolds.
  • Individually short-circuit proof outputs with 0.5 A maximum output current per channel.
  • Integrated Distributed Clocks functionality for precise synchronization across the EtherCAT network.
  • Rugged environmental design with IP65, IP66, and IP67 ingress protection ratings.
  • EtherCAT communication interface utilizing shielded, screw-type M8 sockets.

Applications

  • Direct integration with pneumatic valve terminals and manifold systems.
  • Decentralized actuator control in automotive assembly and robotic lines.
  • Field-level I/O processing in material handling and packaging systems.
  • General manufacturing automation requiring direct, cabinet-free mounting.

Technical Specifications

Manufacturer Beckhoff
Model/Part Number EP2816-0010
Protocol EtherCAT
Number of Outputs 16
Nominal Output Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel (individually short-circuit proof, total limit 4.0 A)
Short-Circuit Current Max. 1.5 A
Load Types Ohmic, inductive, lamp load
Switching Times (Typical) T ON: 60 us, T OFF: 300 us
Current Consumption (Us) 120 mA
Auxiliary Power Current Typ. 20 mA + load
Distributed Clocks Yes
Electrical Isolation 500 V
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Vibration / Shock Resistance Conforms to EN 60068-2-6 / EN 60068-2-27
EMC Immunity / Emission Conforms to EN 61000-6-2 / EN 61000-6-4
Protection Rating IP65 / IP66 / IP67 (conforms to EN 60529)
Weight Approx. 165 g

Connections and Interfaces

Connection Type Interface Style Function
Bus Interface 2 x M8 socket, shielded, screw type EtherCAT input and downstream extension
Output Connections 2 x D-sub socket, 9-pin 16 digital outputs for actuator/valve terminals
Power Supply Feed 1 x M8 male socket, 4-pin Incoming control and auxiliary power (Us/Up)
Power Supply Downstream 1 x M8 female socket, 4-pin Power distribution loop-through to adjacent modules

Installation Guidelines

  • Mounting: Install directly onto flat machine structures or profiles using integrated mounting holes. Variable mounting positions are supported.
  • Shielding & Grounding: Ensure proper connection of the shielded M8 EtherCAT cables to achieve reliable grounding and maintain full EMC compliance.
  • Cable Routing: Keep communication cabling and high-power actuator lines separated where possible to avoid electrical interference.
  • Environmental Protection: To maintain the IP65/66/67 protection rating, ensure all unused M8 and D-sub ports are sealed with appropriate protective caps.

Compliance and Certifications

  • CE
  • UL

What type of connection interface does the EP2816-0010 use for outputs?

The EP2816-0010 features two 9-pin D-sub sockets, making it highly suitable for direct integration with multi-pin valve manifolds and valve terminals.

What is the maximum output current supported per channel?

Each digital output channel supports a maximum current of 0.5 A. All channels are individually short-circuit proof, and the total sum current limit across all outputs is 4.0 A.

Does this EtherCAT Box support Distributed Clocks (DC)?

Yes, the EP2816-0010 has native support for Distributed Clocks, enabling high-precision, synchronized execution of digital outputs.

What is the environmental ingress protection rating of the EP2816-0010?

The module is rated for IP65, IP66, and IP67 protection according to EN 60529, allowing direct, cabinet-free mounting in wet, dusty, and demanding industrial environments.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Németország

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...