1 / 1

Beckhoff ER2338-1001 EtherCAT Box 8-channel Digital Input/Output Module

Beckhoff ER2338-1001 EtherCAT Box 8-channel Digital Input/Output Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: ER2338-1001

  • Country of origin:Németország

  • Product Type: EtherCAT Box Modules

  • Payment: T/T, Western Union

  • Weight: 500g

  • Dimensions: 150 x 50 x 40 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Direct physical-level integration of decentralized field signals is achieved via the Beckhoff ER2338-1001 EtherCAT Box, which features eight bi-directional, freely configurable digital channels housed in a robust, moisture-resistant IP67 enclosure. This module interfaces directly with sensors and actuators at the machine level, eliminating the need for protective control cabinets and reducing field wiring overhead.

Key Features

  • Freely Configurable I/O: Each of the 8 channels can be independently configured as a digital input or digital output via the TwinCAT control software.
  • High-Speed Switching: Features rapid switching times with a typical turn-on time of 50 microseconds and a turn-off time of 100 microseconds.
  • Robust M8 Connectivity: Equipped with secure, shielded M8 screw-type connectors for both EtherCAT communication and physical I/O channels.
  • Comprehensive Protection: Built-in short-circuit protection for sensor supply and outputs, with an IP65/66/67 ingress rating.
  • Electrical Isolation: Provides 500 V electrical isolation to protect sensitive upstream control electronics from field-side electrical noise.

Industrial Applications

  • Automotive Assembly Lines: Direct mounting on robotic arms and conveyor systems where space is limited and exposure to fluids is common.
  • Packaging Machinery: High-speed sorting, counting, and pneumatic valve actuation without localized terminal enclosures.
  • Material Handling Systems: Distributed sensor networks along extensive conveyor lines utilizing daisy-chained EtherCAT topology.
  • Food and Beverage Processing: Wet-area deployments requiring washdown-compatible IP67 fieldbus modules.

Technical Specifications

Parameter Value / Specification
Manufacturer Beckhoff Automation
Model / Article Number ER2338-1001
Protocol EtherCAT
Bus Interface 2 x M8 socket, shielded, screw type
Number of Channels 8 digital inputs or outputs (freely configurable)
Input/Output Connections M8 x 1, 3-pin, A-coded
Input Filter Time 3.0 ms
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 11 to 30 V (6 mA input current, EN 61131-2, type 3)
Sensor Supply Derived from load supply voltage, max. 0.5 A total, short-circuit proof
Load Types Supported Ohmic, inductive, lamp load
Rated Load Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel
Current Consumption from US 120 mA
Power Supply Connection Feed: 1 x M8 male, 4-pin; Downstream: 1 x M8 female, 4-pin
Electrical Isolation 500 V
Operating Temperature -25 to +60 degC
Storage Temperature -40 to +85 degC
Protection Rating IP65/66/67 (conforms to EN 60529)
Approvals CE, UL
Country of Origin Germany
Shipping Weight (Calculated) 2.0 kg
Package Dimensions (Calculated) 150 x 50 x 40 mm

Connections and Interfaces

Connector Type Pin Number Function Assignment
I/O M8 Sockets (3-pin) Pin 1 +24 V DC Sensor Supply (US)
Pin 3 GND (US)
Pin 4 Input/Output Signal (Configurable)
Power Feed M8 (4-pin) Pin 1 +24 V DC Control Voltage (US)
Pin 2 +24 V DC Peripheral Voltage (UP)
Pin 3 GND (US)
Pin 4 GND (UP)

Empirical Engineering Insights

Alternative Models & Compatibility

The ER2338-1001 features a plastic housing designed for standard industrial environments. For applications requiring extreme mechanical resilience or resistance to aggressive chemical solvents, the EP2338-1001 (zinc die-cast housing) serves as the direct functional equivalent. Both modules share identical XML device description files (ESI) in TwinCAT, allowing drop-in replacement without software modification.

Application Pitfalls & Engineering Notes

When utilizing channels as outputs, ensure the total current draw of all connected actuators does not exceed the thermal dissipation limits of the module. While individual channels can switch up to 0.5 A, simultaneous high-duty-cycle operation of all outputs at maximum load in high ambient temperatures (above 50 degC) can trigger internal thermal shutdown. Always calculate the cumulative load on the US and UP power paths.

Commissioning & Wiring Tips

To guarantee IP67 integrity, unused M8 ports must be sealed with industrial-grade protective caps. When routing EtherCAT communication, use only double-shielded, twisted-pair M8 cables. Ground loops can be avoided by ensuring the module's metal mounting tabs are bonded directly to a clean, low-impedance machine ground plane rather than relying solely on the cable shielding.

Installation Guidelines

CRITICAL WARNING: De-energize all system power sources (both US control/sensor power and UP actuator power) before initiating installation, cable routing, or module replacement. Hot-plugging M8 I/O or power connectors can cause transient electrical arcs, leading to permanent damage to the internal EtherCAT transceiver ASIC.
1
Mount the module on a flat, vibration-resistant surface using two M3 screws. Ensure the mounting surface is clean and free of paint to establish a solid ground connection via the mounting eyelets.
2
Connect the incoming EtherCAT network cable to the left-hand M8 socket (IN) and the downstream cable to the right-hand M8 socket (OUT). Torque the M8 locking collars to 0.4 Nm.
3
Wire the M8 power feed connector, ensuring proper separation of the US (system/sensor) and UP (actuator/load) power circuits to maintain electrical isolation.
4
Scan the EtherCAT network within TwinCAT System Manager to automatically detect the module, then configure each channel's operational mode (Input or Output) in the process data settings.

Can the digital channels on the ER2338-1001 be configured as inputs and outputs simultaneously?

Yes, each of the 8 channels can be independently operated as either a digital input or a digital output. Configuration is handled dynamically via TwinCAT without physical hardware modification.

What is the maximum current capacity for the sensor supply?

The sensor supply is derived from the US load supply voltage and provides a maximum of 0.5 A in total across all channels. It is fully short-circuit proof.

How is the EtherCAT network connected to this module?

The network is connected via two shielded, screw-type M8 sockets. One acts as the EtherCAT input (Upstream) and the other as the output (Downstream) to daisy-chain additional boxes.

What is the physical difference between the ER2338-1001 and the EP2338-1001?

The ER2338-1001 is housed in a lightweight plastic enclosure, whereas the EP2338-1001 features a heavy-duty zinc die-cast housing. They are functionally and electrically identical.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Németország

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...