1 / 1

Beckhoff ER6001-0002 EtherCAT Box Serial Interface Module

Beckhoff ER6001-0002 EtherCAT Box Serial Interface Module

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: ER6001-0002

  • Country of origin:Németország

  • Product Type: Serial Interface Modules

  • Payment: T/T, Western Union

  • Weight: 265g

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Designed for direct connection of serial devices to EtherCAT networks without an electrical cabinet, the Beckhoff ER6001-0002 serial interface module provides a highly ruggedized, IP67-rated solution for industrial field installations. This module enables the seamless integration of devices featuring RS232, RS422, or RS485 interfaces directly into the EtherCAT communication ring. The interface type is individually selectable per channel, allowing versatile configuration based on system requirements.

Equipped with an integrated 5 V DC sensor supply and auxiliary digital inputs and outputs, the ER6001-0002 serves as an all-in-one local connection point. Its heavy-duty zinc die-cast housing ensures superior resistance to mechanical stress, moisture, and electromagnetic interference, making it an ideal choice for decentralised control environments across heavy industries.

Features

  • Individually selectable serial interfaces: RS232, RS485, or RS422.
  • Robust 864-byte receive buffer and 128-byte transmit buffer to prevent data loss.
  • Two auxiliary 24 V DC digital inputs and two short-circuit proof digital outputs.
  • Dedicated +5 V DC, 1 A sensor power supply.
  • Standardised M12 connection technology for secure sensor and serial device coupling.
  • Integrated M8 EtherCAT bus interfaces with shielded, screw-type connection.
  • Fully encapsulated housing featuring IP65, IP66, and IP67 protection ratings.

Applications

  • Direct machine-level integration of barcode scanners, printers, and weight indicators.
  • Oil and gas field instrumentation and distributed telemetry systems.
  • Power generation and substation auxiliary device communication.
  • Water and wastewater plant field monitoring and control.

Technical Specifications

ManufacturerPart Number / ModelProduct SeriesProtocolSelectable InterfacesData Transfer RatesCommunication ModeData BufferSensor SupplyDigital InputsDigital OutputsBus InterfaceConnection MethodNominal VoltageCurrent ConsumptionElectrical IsolationOperating TemperatureStorage TemperatureProtection RatingWeight
Beckhoff
ER6001-0002
EtherCAT Box
EtherCAT
RS232, RS485, RS422
300 to 115,200 baud (9600 baud preset, 8N1)
TxD and RxD, full duplex
864 bytes receive buffer, 128 bytes transmit buffer
+5 V DC, 1 A
2 x digital inputs, 24 V DC (10 us filter, 11...30 V "1" signal)
2 x digital outputs, 24 V DC (0.5 A per channel, short-circuit proof)
2 x M8 socket, shielded, screw type
M12 x 1, 5-pin, A-coded
24 V DC (-15% / +20%)
Typically 130 mA + load
500 V
-25 to +60 degC
-40 to +85 degC
IP65, IP66, IP67 (conforms to EN 60529)
Approx. 265 g

Connections and Interfaces

Interface Connection Connector Standard Functional Assignment
EtherCAT Bus Input/Output 2 x M8 Socket, Shielded EtherCAT fieldbus ring communication
Serial & I/O Connections M12 x 1, 5-pin, A-coded Serial transmit/receive data, auxiliary inputs, outputs, and sensor power
Power Supply Feed 1 x M8 Male Socket, 4-pin Control (US) and load voltage (UP) feed
Power Supply Downstream 1 x M8 Female Socket, 4-pin Downstream loop connection for power distribution

Installation Guidelines

  • Mount the module directly to the machine frame or mounting plate. No protective enclosure or cabinet is required thanks to the IP67 housing rating.
  • Ensure all M8 and M12 connectors are securely tightened to the specified torque to maintain the integrity of the environmental seal.
  • Use shielded cabling for all serial communication lines (RS232/RS422/RS485) and ensure the shield is properly terminated at the connector.
  • Keep total serial cable lengths within safe limits: maximum 15 m for RS232 connections, and up to 1000 m for RS422/RS485 networks.

Compliance and Certifications

  • CE
  • UL
  • EMC Immunity/Emission: Conforms to EN 61000-6-2 / EN 61000-6-4
  • Vibration/Shock Resistance: Conforms to EN 60068-2-6 / EN 60068-2-27

Which serial communication standards are supported by the ER6001-0002?

The Beckhoff ER6001-0002 supports RS232, RS422, and RS485 communication. The protocol is individually selectable depending on the connected end device.

What is the protection rating of this module?

The module has an IP65, IP66, and IP67 protection rating according to EN 60529, allowing it to be installed directly on machines without requiring a control cabinet.

What type of sensor supply does the module provide?

The module features an integrated +5 V DC sensor supply rated up to 1 A, which can power connected serial devices and sensors directly.

Are there digital inputs and outputs on the ER6001-0002?

Yes, the module includes 2 digital 24 V DC inputs with a 10 us input filter and 2 short-circuit proof digital 24 V DC outputs rated up to 0.5 A per channel.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Németország

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...