1 / 1

Beckhoff KS3132 Bus Terminal

Beckhoff KS3132 Bus Terminal

Only 10 item(s) left in stock
  • Manufacturer: BECKHOFF

  • Product No.: KS3132

  • Country of origin:Németország

  • Product Type: Bus Terminals

  • Payment: T/T, Western Union

  • Weight: 70g

  • Dimensions: 68 mm x 12 mm x 100 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Engineered for high-accuracy differential measurement in demanding automation architectures, the Beckhoff KS3132 is a premium 2-channel analog input terminal designed to interface directly with standard K-bus backplane systems. By processing voltage signals in the -10 V to +10 V range with a native 16-bit conversion engine, this unit translates physical inputs into precise digitized values with high immunity to common-mode electrical interference. The inclusion of a pluggable wiring system allows field technicians to remove and insert the active electronics cartridge without disturbing the pre-installed field wiring loom, minimizing system downtime during maintenance cycles.

Features

  • Dual-Channel Differential Inputs: Provides two independent differential analog channels to suppress common-mode noise across extended signal runs.
  • 16-Bit Resolution: High-resolution sampling (15-bit resolution for standard 0 to 10 V scaling) ensures precise feedback for fine closed-loop processes.
  • Pluggable Wiring Level: The KS series architecture permits tool-free modular swapping while keeping the field wiring termination intact.
  • Configurable 50 Hz Filter: Built-in configurable low-pass filter specifically targeted to suppress industrial line frequency interference.
  • Galvanic Isolation: 500 V electrical isolation between the internal K-bus and the analog measurement circuitry to shield upstream controllers from field-side voltage transients.

Applications

  • Precision Positioning Systems: Interfacing with analog position feedback sensors, linear transducers, and encoders.
  • Process Instrumentation: Monitoring differential pressure transmitters, flow meters, and flow control loops.
  • Hazardous Area Control: Direct DIN-rail integration inside explosive environments matching ATEX Zone 2 design constraints.

Technical Specifications

Parameter Value
Manufacturer Beckhoff
Model Number KS3132
Number of Inputs 2
Signal Range -10 V to +10 V
Technology Differential Input
Internal Resistance > 70 kOhm
Common-Mode Voltage (Ucm) 10 V maximum
Resolution 16 bit (15 bit for 0 to 10 V range)
Conversion Time 140 ms (configurable)
Hardware Filter 50 Hz (configurable)
Measuring Error < ±0.05% (relative to full scale value)
Electrical Isolation 500 V (K-bus / signal voltage)
K-Bus Current Consumption Typical 85 mA
Power Contact Contacts None
ATEX Classification II 3 G Ex nA IIC T4 Gc
Operating Temperature Range 0 to +55 degC
Storage Temperature Range -25 to +85 degC
Relative Humidity 95%, non-condensing
Housing Material Polycarbonate
Mounting 35 mm DIN rail (EN 60715) with double slot lock
Dimensions (L x W x H) 68 mm x 12 mm x 100 mm
Net Weight 0.07 kg

Connections and Interfaces

Terminal Connection Signal Description
Terminal 1 Input + (Channel 1)
Terminal 5 Input - (Channel 1)
Terminal 2 Input + (Channel 2)
Terminal 6 Input - (Channel 2)
Terminal 3 Shield Connection (Channel 1)
Terminal 7 Shield Connection (Channel 2)
Terminal 4 / 8 No Connection (Internal reserve)

Empirical Engineering Insights

Alternative Models & Compatibility

The KS3132 shares identical software registers, electrical parameters, and TwinCAT process image structures with the standard KL3132. The primary differentiator is the KS series pluggable connector housing. If standard-wired KL3132 modules are present in your existing fieldbus nodes, they can be directly interchanged with the KS3132 provided the terminal connector head matches the plug-in base pattern.

Application Pitfalls & Engineering Notes

Because this module does not route power contacts to the adjacent bus slices (it does not feature power rail pass-through tabs), it cannot feed operating current to field-side instruments. Loop or external auxiliary power must be provided downstream. Additionally, when using the 0 to 10 V input profile, the physical resolution drops from the bipolar 16 bits to 15 bits. System designers must account for this reduction in quantization when writing process automation calculations.

Commissioning & Wiring Tips

Always employ shielded twisted pair (STP) wiring for both differential paths. Connect the shielding drain wire directly to terminals 3 or 7 on the module, or to a low-impedance grounding bar positioned near the entry point of the control panel. If you experience signal attenuation or measurement oscillation, confirm that the TwinCAT register configurations match your filter profiles; the internal 50 Hz digital notch filter can be modified in software using direct register access paths (specifically Register R32).

Installation Guidelines

CRITICAL WARNING

Isolate all electrical feeds to the K-bus coupler and external field sensors before inserting, extracting, or wiring the module. Working on live active terminal blocks poses a risk of damaging internal backplane optocouplers and can cause process disruptions on neighboring nodes.

1
Mount the terminal block body by sliding it onto standard 35 mm DIN rail until the lock mechanism clicks firmly, aligning the slide keys with adjacent terminals.
2
Using a flat-head screwdriver (0.4 x 2.5 mm), actuate the cage clamp spring mechanisms to terminate the field inputs using the proper stripping length of 9 to 10 mm.
3
Plug the pre-wired connector block into the KS3132 base unit, ensuring that the locking lugs click securely into position.
4
Power on the bus coupler and execute the TwinCAT configuration scan to confirm that the node reports error-free process data transmission status.

What is the primary difference between the Beckhoff KS3132 and the KL3132?

The KS3132 features a pluggable wiring level, enabling fast hot-swaps of terminal blocks without disconnecting individual signal wires, whereas the KL3132 has fixed wiring terminals.

Does the KS3132 supply power to field sensors directly?

No, this module does not have power contacts for sensor supply distribution. Field instrumentation must be powered via external supply units or power feed terminals.

How do you configure the internal filter frequency on this module?

The 50 Hz filter and conversion times can be modified within the TwinCAT System Manager by writing directly to the module's internal register structures (such as Feature Register R32).

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Németország

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...