1 / 1

Delta Electronics VFD33AMS23ANSAA MS300 Series Standard Compact Drive

Delta Electronics VFD33AMS23ANSAA MS300 Series Standard Compact Drive

Only 10 item(s) left in stock
  • Manufacturer: Delta Electronics

  • Product No.: VFD33AMS23ANSAA

  • Country of origin:Egyesült Államok

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 3970g

  • Dimensions: 130 mm x 185 mm x 250 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Optimized for dynamic speed control in space-restricted environments, the Delta Electronics VFD33AMS23ANSAA variable frequency drive offers reliable open-loop vector control for both induction and permanent magnet motors. This 7.5 kW (10 HP) standard compact drive features a dual-rating design, allowing engineers to configure it for Normal Duty (ND) or Heavy Duty (HD) operations based on direct load dynamics. With its built-in Safe Torque Off (STO) function, the drive integrates seamlessly into machine safety networks, eliminating the need for redundant external safety contactors. The unit operates on a 3-phase 200V to 240VAC input and does not include an internal EMC filter, making it ideal for standard power grids and applications where external line filtration is managed separately.

Features

  • Dual-Duty Configuration: Supports Normal Duty (36 A output) for centrifugal loads and Heavy Duty (33 A output) for constant torque loads.
  • Safe Torque Off (STO): Integrated hardware-based SIL2/PLd STO input ensures immediate shutdown of output power transistors for safe maintenance or emergency stops.
  • Flexible Motor Control: Compatible with both induction motors (IM) and permanent magnet (PM) synchronous motors.
  • Adjustable Switching Frequency: Configurable carrier frequency from 2 to 15 kHz to minimize audible motor noise or reduce drive thermal dissipation.
  • Compact Form Factor: Designed for high-density DIN-rail or backplate mounting with zero-clearance side-by-side spacing up to 40 degC ambient.

Applications

  • Material Handling: Belt conveyors, sorting systems, and small gantry cranes.
  • Pumping and Ventilation: Wastewater pumps, booster systems, and exhaust fans.
  • Machine Tooling: Spindle drives, grinding machines, and localized drilling axes.
  • Packaging and Processing: Labeling machines, wrapping lines, and food mixers.

Technical Specifications

Parameter Value
Manufacturer Delta Electronics
Model Reference VFD33AMS23ANSAA
Series Type MS300 (Standard Compact Drive)
Nominal Output Power 7.5 kW (10 HP)
Input Voltage / Phase 3-phase 200V to 240VAC (-15% to +10%)
Input Frequency Range 50 / 60 Hz
Rated Output Current (ND) 36.0 A
Rated Output Current (HD) 33.0 A
EMC Filtering No internal filter (No function)
Safety Integrated Safe Torque Off (STO) SIL2 / PLd
Carrier Frequency Range 2 to 15 kHz (Default: 4 kHz)
Enclosure Protection IP20 / Open Type
Physical Dimensions 130 mm x 185 mm x 250 mm
Net Unit Weight 3.97 kg
Shipping Weight (Calculated) 5.00 kg

Connections and Interfaces

Terminal Designation Functional Assignment
R/L1, S/L2, T/L3 3-phase AC main power supply connection input
U/T1, V/T2, W/T3 Variable output connection to 3-phase AC induction or PM motor
+1, +2 / B1 DC reactor connection point (remove factory jumper before installation)
+2 / B1, B2 Terminals for external dynamic braking resistor
S1, S2, +24V, SC Safe Torque Off (STO) dual-channel safety inputs and common reference

Empirical Engineering Insights

Alternative Models & Compatibility

The VFD33AMS23ANSAA belongs to Delta's high-efficiency MS300 series. If replacing a legacy VFD-M or VFD-E series drive with this unit, note that parameter mapping differs completely. Key commissioning parameters such as acceleration times, V/f ratios, and multi-step speed inputs must be re-entered manually. If swapping this non-filtered (ANSAA) unit with a filtered model (AFSAA), you must ensure sufficient enclosure depth to accommodate the physical profile differences, and verify that the system grounding arrangement handles the increased leakage currents associated with internal EMC filters.

Application Pitfalls & Engineering Notes

Under heavy-duty operation, the drive is engineered to manage a 150% current overload for up to 60 seconds. If your mechanical process demands frequent cyclical acceleration peaks, monitor the heat sink temperatures via parameter diagnostics to avoid thermal tripping. Side-by-side mounting is supported to minimize backplate space; however, if units are installed adjacent to one another without gaps, the protective top labels must be removed, and the maximum safe operating threshold drops to 40 degC to avoid localized hot-spot damage.

Commissioning & Wiring Tips

Before powering up the motor, perform a complete rotational or static auto-tune by setting Parameter 05-00 to 1 or 2 (depending on load connection status). This calculates the motor’s internal winding resistance and inductance, which is essential for accurate sensorless vector control. Always route low-voltage analog command signals (0-10V / 4-20mA) and the STO safety loops through shielded, twisted-pair cables, routing them at least 15 cm away from the power and motor lines to suppress high-frequency electrical noise.

Installation Guidelines

CRITICAL SAFETY WARNING

Isolate and lock out all input power lines before attempting terminal wire routing. The DC bus capacitors retain dangerous voltages (>36 VDC) for a prolonged period after primary AC power removal. Wait a minimum of 10 minutes following de-energization and use a digital multimeter to measure and verify zero potential across the positive terminal (+1/+2) and negative bus before commencing physical work.

1

Mount the drive vertically on a flat, non-flammable vertical support backplate, maintaining a minimum clearance of 50 mm above and below the chassis for unimpeded cooling airflow.

2

Securely connect the primary earth grounding conductor to the drive's dedicated protective ground (PE) terminal. Never daisy-chain ground terminals between multiple VFDs.

3

Wire the 3-phase AC input lines to R/L1, S/L2, and T/L3, and terminate the output motor lines to U/T1, V/T2, and W/T3 using rated torque specifications to prevent terminal overheating.

Does this drive include an integrated EMC filter?

No, this model features the ANSAA suffix, indicating that it does not contain an integrated EMC filter. External filtering must be added if compliance with specific EMC standards is required.

What is the physical size and footprint of this unit?

The unit measures 130 mm in width, 185 mm in depth, and 250 mm in height, with a net weight of approximately 3.97 kg, designed for space-conscious electrical enclosures.

Can this drive run both permanent magnet and induction motors?

Yes, the MS300 control platform supports open-loop vector and V/f control for both traditional induction motors (IM) and permanent magnet (PM) synchronous motors.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...