1 / 1

Mitsubishi Electric FR-A840-75K-1 FR-A800 Series Variable Frequency Drive

Mitsubishi Electric FR-A840-75K-1 FR-A800 Series Variable Frequency Drive

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-A840-75K-1

  • Country of origin:Egyesült Államok

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 53000g

  • Dimensions: 465 mm x 595 mm x 300 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Engineered for high-demand heavy industrial applications, the Mitsubishi Electric FR-A840-75K-1 variable frequency drive delivers precise speed and torque control for motors up to 75 kW. Incorporating advanced vector control algorithm technologies, this three-phase 400V class inverter maximizes operational uptime and system efficiency in demanding processing environments. The unit features a dedicated FM terminal configured for high-speed pulse train output, enabling real-time feedback and seamless integration into higher-level DCS and PLC architectures.

Features

  • Real Sensorless Vector Control: Achieves high-accuracy torque control and exceptional dynamic response without requiring a physical speed encoder.
  • Built-in RS-485 Communication: Supports Modbus-RTU and Mitsubishi standard protocols directly via the RJ-45 interface, with expansion options for CC-Link, Profibus-DP, EtherCAT, and PROFINET.
  • Enhanced Terminal FM Interface: Provides high-speed pulse train output (up to 55 kHz) for monitoring critical operating parameters such as output frequency or motor speed.
  • High Overload Capacity: Designed to withstand heavy-duty industrial cycles with dual ratings for Normal Duty (ND) and Light Duty (LD) operational demands.
  • Built-in PLC Functionality: Allows custom logic sequences to be programmed directly within the drive, reducing the need for external control components.

Applications

  • Heavy-duty industrial extraction fans and high-volume ventilation blowers.
  • Multi-stage centrifugal pumps and water treatment processing systems.
  • Heavy-material conveyors, overhead cranes, and material handling gantries.
  • Compressors, extruders, and industrial mixing machinery.

Technical Specifications Table

Specification Parameter Value / Rating
Manufacturer Mitsubishi Electric
Model Number FR-A840-75K-1
Applicable Motor Capacity 75 kW (Heavy Duty) / 90 kW (Normal Duty)
Input Voltage Class Three-Phase 380 to 500 V AC (50/60 Hz)
Rated Output Current 144 A (Heavy Duty) / 180 A (Normal Duty)
Output Capacity 110 kVA
Control Method V/F Control, Advanced Magnetic Flux Vector Control, Real Sensorless Vector Control
Monitor Output Terminal Terminal FM (Pulse Train Type)
Communication Protocols RS-422, RS-485 (Built-in Modbus RTU)
Protective Rating IP00 (Open Type)
Operating Temperature -10 degC to +50 degC (Non-freezing)
Compliance & Certifications CE, UL, cUL, RoHS compliant
Country of Origin Japan
Shipping Weight (Calculated) 53.0 kg (116.8 lbs)
Physical Dimensions (W x H x D) 465 mm x 595 mm x 300 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-A840-75K-1 serves as the direct replacement for the legacy FR-A740-75K model series. While the footprint and control terminal layouts are largely identical, parameter migration must be handled carefully. When upgrading, parameters should be exported via FR Configurator2 software to ensure custom logic programs and PID loop configurations translate correctly. Note that the "-1" suffix designates the unit equipped with the FM terminal interface (pulse output) as opposed to the "-2" suffix which features an AM terminal (analog voltage output).

Application Pitfalls & Engineering Notes

Operating a 75 kW high-capacity drive generates substantial thermal loads, approximately 1850 Watts of heat dissipation at full capacity. Enclosing this unit within sealed IP54 panels requires forced mechanical cooling to prevent the internal heatsink from exceeding 50 degC, which triggers an overtemperature warning (E.THT). Additionally, installing an external DC link reactor (FR-HEL) is highly recommended to protect the rectifier bridge from input line surges and reduce high-frequency harmonic feedback into the distribution transformer.

Commissioning & Wiring Tips

When routing cables for the FM pulse output terminal, use braided, shielded twisted-pair (STP) wiring with a minimum wire cross-section of 0.75 mm2. Keep control cables physically isolated from the output motor phases (U, V, W) by a distance of at least 30 cm to prevent EMI noise injection, which can distort pulse output readings. If the drive displays an E.UVT (Undervoltage) fault during ramp-up, verify that the input voltage supply does not sag below 323 V AC under transient loading conditions.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE RISK

Isolate all primary feed circuits before executing installation. Wait a minimum of 10 minutes post-power-down to allow internal DC bus capacitors to discharge below safety thresholds. Confirm that the DC bus voltage across terminals P/+ and N/- is measured at 0 V with a rated digital multimeter before initiating terminal modifications.

1

Mount the drive vertically on a flat, non-flammable vertical backplate to optimize convection cooling currents across the heatsink assembly.

2

Connect the mains power cabling to terminals R/L1, S/L2, and T/L3. Connect the output motor cabling to terminals U, V, and W. Ensure all ground lugs are connected to a low-impedance facility earth bus.

3

Perform a dry run setup with the motor disconnected. Set Parameter 9 (Motor Rated Current) and Parameter 71 (Applied Motor Selection) via the onboard PU display before running an autotuning sequence.

What is the primary difference between the FR-A840-75K-1 and FR-A840-75K-2?

The FR-A840-75K-1 is equipped with an FM terminal configuration that utilizes pulse train outputs for monitoring. The -2 version features an AM terminal configuration designed for conventional analog voltage outputs.

Does this drive require an external DC reactor for standard operation?

While not mandatory for basic operation, installing a matching DC link reactor (such as the FR-HEL) is highly recommended for 75 kW systems to minimize harmonics and protect internal rectifiers.

How do I clear an E.THT fault code on the FR-A840-75K-1?

An E.THT fault indicates inverter overload. Verify the motor current draw, inspect the cooling fans for dust blockage, and check that ambient enclosure temperatures remain below 50 degrees Celsius.

Can this variable frequency drive run permanent magnet (PM) motors?

Yes, the FR-A800 series supports both induction motors and permanent magnet (IPM/SPM) motors using real sensorless vector control configurations.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...