1 / 1

Mitsubishi Electric FR-CS84-295-60 FREQROL-CS80 Series Variable Frequency Drive Inverter

Mitsubishi Electric FR-CS84-295-60 FREQROL-CS80 Series Variable Frequency Drive Inverter

Only 10 item(s) left in stock
  • Manufacturer: Mitsubishi Electric

  • Product No.: FR-CS84-295-60

  • Country of origin:Egyesült Államok

  • Product Type: Variable Frequency Drives

  • Payment: T/T, Western Union

  • Weight: 6000g

  • Dimensions: 260 mm x 220 mm x 195 mm

  • Shipping port: Xiamen

  • Warranty: 12 months

Mennyiség
Minden részlet megtekintése

Description

Managing heavy-duty three-phase motor applications requires highly dependable frequency control, which is precisely where the Mitsubishi Electric FR-CS84-295-60 excels. Engineered as a core variable frequency drive (VFD) within the highly compact FREQROL-CS80 series, this high-performance inverter is rated to drive induction motors with capacities up to 15 kW. Designed to deliver optimized magnetic flux vector control, it provides outstanding torque output even at lower rotational speeds, making it an excellent match for sophisticated machinery configurations in diverse industrial sectors.

Key Features

  • Space-Saving Envelope: Designed with a minimized physical footprint to allow high-density DIN-rail or backpanel installation.
  • Excellent Torque Response: Incorporates advanced magnetic flux vector control to stabilize motor performance during variable load cycles.
  • High Overload Resilience: Engineered to withstand transient spikes, with a rating of 150% for 60 seconds and 200% for 0.5 seconds.
  • Integrated Protection Circuits: Active monitoring guards against overcurrent, regenerative overvoltage, and thermal motor overload.
  • Maintenance-Free Terminals: Utilizes spring clamp terminal blocks to guarantee secure, vibration-resistant wiring.

Applications

  • Heavy material handling systems and industrial conveyors.
  • Centrifugal pumps, booster systems, and municipal fluid machinery.
  • High-capacity ventilation systems and industrial exhaust blowers.
  • Packaging, wrapping, and automated assembly equipment.

Technical Specifications

Parameter Value / Specification
Manufacturer Mitsubishi Electric
Model Number FR-CS84-295-60
Series FREQROL-CS80
Applicable Motor Capacity 15 kW
Rated Capacity 22.5 kVA
Rated Output Current 29.5 A (Derated to 25.1 A under high-carrier frequency)
Rated Input AC Voltage / Frequency Three-phase 380 to 480 V AC, 50/60 Hz
Permissible AC Voltage Fluctuation 325 to 528 V AC, 50/60 Hz
Permissible Frequency Fluctuation +/-5%
Power Supply Capacity Requirement 28.0 kVA
Overload Current Rating 150% for 60 seconds, 200% for 0.5 seconds (Inverse-time characteristics)
Shipping Weight 6.0 kg
Estimated Packaging Dimensions 260 mm x 220 mm x 195 mm

Connections and Interfaces

Terminal / Port Signal Assignment / Description
R/L1, S/L2, T/L3 Three-phase AC mains power input terminals
U, V, W Three-phase variable frequency output to induction motor
STF / STR Forward Run / Reverse Run command input
SD Common terminal for control input signals (Isolated Ground)
AM / 5 / 10 / 4 Analog output monitor and analog frequency setting inputs (0-10V, 4-20mA)

Empirical Engineering Insights

Alternative Models & Compatibility

The FR-CS84-295-60 represents a modernized path for systems previously running on discontinued FR-E740 or FR-S540 units in standard V/F or basic vector applications. Note that the physical size and footprint may vary; the CS80 is optimized for maximum vertical space saving. Confirm existing parameter settings when migrating, as parameter structures and address mappings correspond to newer Mitsubishi control profiles.

Application Pitfalls & Engineering Notes

When using this drive under continuous duty at elevated switching carrier frequencies (above standard defaults), the output current limits must be derated from 29.5 A down to 25.1 A to prevent premature thermal overload trips. Always ensure the internal cooling fan is clean and has adequate ventilation clearances on the top and bottom of the drive (minimum of 5 cm spacing in the enclosure).

Commissioning & Wiring Tips

To eliminate electromagnetic interference (EMI) issues, run control logic wiring separately from the high-voltage motor output lines (minimum 10 cm separation). Always utilize twisted, shielded instrumentation cable for any analog reference signals connected to terminal 2 and 4, ensuring the shield is grounded at the VFD end only.

Installation Guidelines

CRITICAL WARNING: Hazardous voltages remain present on the internal DC bus capacitors for several minutes after the main power is disconnected. Never work on the terminal blocks or internal circuitry until you have confirmed with a digital multimeter that the voltage across terminals P/+ and N/- is safely discharged. Failure to do so may result in severe shock or equipment destruction.
1

Mount the inverter vertically on a flat, non-flammable back panel within a clean, dust-free industrial enclosure.

2

Connect the physical ground wire to the PE terminal before completing any electrical supply connections.

3

Verify that the line voltage matches the rated range of 380 to 480 V AC, and connect supply lines to terminals R/L1, S/L2, and T/L3.

4

Establish output wiring from terminals U, V, and W directly to the motor, ensuring no power factor capacitors are in line.

What is the primary function of the FR-CS84-295-60 inverter?

It is a variable frequency drive used to control the speed and torque of three-phase induction motors up to 15 kW in industrial applications.

Why are there two different rated current values listed in the specifications?

The normal rating is 29.5 A. If the switching carrier frequency is increased to minimize acoustic motor noise, the drive must be derated to 25.1 A to manage internal thermal generation.

Does this model support Modbus RTU communications?

Yes, the FREQROL-CS80 series includes built-in RS-485 communication options supporting Modbus RTU protocol for remote monitoring and control.

What type of wire is recommended for the control terminals?

It is recommended to use flexible, stranded wires with a cross-sectional area between 0.3 and 1.25 mm2. Ensure to use ferrules for clean insertion into the spring clamp terminals.

Globális expressz szállítás

  • Normál szállítás: 4-6 munkanap a DHL, FedEx és UPS szolgáltatásával.
  • Gyors kiszállítás: A raktáron lévő, 14:00 (GMT+8) előtt leadott megrendeléseket aznap feladjuk.
  • Világszintű lefedettség: Több mint 150 országban szolgálunk ki, beleértve a gyors szállítást Szaúd-Arábiába és az Egyesült Arab Emírségekbe.

Visszaküldés és garancia

  • 30 napos garancia: Csak a raktáron lévő termékek eredeti, gyári zárt csomagolásban történő visszaküldését fogadjuk el.
  • 12 hónapos garancia: Minden ipari alkatrészünket szakmai műszaki garancia védi.

A megrendeléseket hétfőtől péntekig dolgozzuk fel és szállítjuk (állami ünnepnapok kivételével).


A teljes jogosultság, a készletfeltöltési díjak és a nemzetközi visszaküldési részletek megtekintéséhez kérjük, tekintse meg hivatalos oldalunkat Visszatérítési és Visszaküldési Szabályzat .

TECHNICAL SPECIFICATIONS

Country of origin
Egyesült Államok

Nemrég megtekintett termékek

Műszaki ismeretek

Elektromos működtetők, amelyek a folyadékenergia-rendszereket váltják ki: Gyakorlati ipari automatizálási útmutató

Ez a cikk bemutatja, hogyan alakítják át az integrált elektromos működtetők, például az SMC e-Actuator sorozata, az ipari mozgásvezérlést azáltal, hogy kiváltják a hagyományos pneumatikus és...

Matematikai műveletek OpenPLC-vel ipari automatizálási alkalmazásokhoz

Ez a cikk bemutatja, hogyan hajtanak végre a PLC rendszerek alapvető matematikai műveleteket, mint az összeadás, kivonás, szorzás, osztás, modulo és hatványozás az ipari automatizálásban. Megmutatja,...

Fejlett Boole-logika FBD PLC programozással: Gyakorlati ipari alkalmazások a alapvető logikán túl

A cikk több fejlett Boole-logikai függvényt ismertet, amelyeket a PLC programozásban használnak az alapvető ÉS, VAGY és NEM műveleteken túl. Bemutatja, hogyan alkalmazhatók olyan eszközök, mint az...

Boole-logika a PLC programozásban: Az FBD logikai kapuk megértése

A Boole-logika minden PLC program alapja. Az egyszerű gépvezérlésektől a bonyolult ipari automatizálási rendszerekig a logikai kapuk határozzák meg, hogyan reagálnak a vezérlők a változó bemenetekre...

Részletes útmutató az ipari tűzfalakról és az OT hálózati szegmentációról

Az ipari tűzfalak kulcsfontosságú szerepet játszanak az OT kiberbiztonságban, védve a PLC, DCS és SCADA hálózatokat szegmentálás, be- és kimeneti forgalom szabályozás, valamint az IEC 62443 elveivel...

Útmutató a robotikus fogókhoz: a finomkezeléstől a nehézüzemi automatizálásig

A modern robotfogók túlmutatnak a hagyományos mechanikus állkapcsokon. A gyíkok tapadó rendszerétől és az élelmiszeripari puha fogóktól az MI-vezérelt raktári eszközökig a fejlett fogástechnológiák...