ABB ACS800-01-0050-3 ACS800 Series Variable Frequency Drive

ABB ACS800-01-0050-3 ACS800 Series Variable Frequency Drive

Hanya 5 item tersisa di stok
  • Produsen: ABB

  • Nomor Produk: ACS800-01-0050-3

  • Negara asal:Swedia

  • Jenis Produk: Variable Frequency Drives

  • Kode batang: 85044095

  • Pembayaran: T/T, Western Union

  • Berat: 34000g

  • Dimensi: 739 mm x 265 mm x 286 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Engineered for precise speed and torque control in heavy-duty industrial applications, the ABB ACS800-01-0050-3 provides reliable motor regulation across variable load profiles. This wall-mounted variable frequency drive features ABB proprietary Direct Torque Control (DTC) technology, enabling high-dynamic accuracy without requiring encoder feedback. Equipped with an integrated AC choke for harmonic mitigation and dynamic braking options, the drive ensures optimal power quality and system protection in demanding environments.

Key Features

  • Direct Torque Control (DTC): Provides premium motor control performance, rapid torque response, and accurate speed regulation.
  • Harmonic Reduction: Features a built-in line reactor (AC choke) to limit input current harmonics and protect internal DC bus components.
  • Robust Enclosure Design: Compact Frame R5 wall-mountable chassis rated for standard IP21 protection.
  • Flexible Control Interface: Features the RMIO control board with extensive analog and digital I/O channels.

Applications

  • Centrifugal Pumps and Fans: Optimized flow regulation and energy savings using quadratic load curves.
  • Conveyor and Material Handling Systems: High starting torque capabilities and smooth acceleration/deceleration control.
  • Mixers and Extruders: Precise constant torque delivery at low operating speeds.

Technical Specifications

Parameter Specification
Manufacturer ABB
Model Designation ACS800-01-0050-3
Frame Size R5
Input Voltage Range 380 to 415 V AC (3-Phase)
Input Frequency 48 to 63 Hz
Normal Duty Rating (Pn) 45 kW / 86 A continuous output
Light Overload Rating (Pld) 37 kW / 80 A continuous output
Heavy Duty Rating (Phd) 30 kW / 60 A continuous output
Apparent Power Output 60 kVA
Efficiency Class IE2
Standby Power Loss 97 W
Operating Temperature Range 0 to 50 degC (derating applicable above 40 degC)
Dimensions (H x W x D) 739 mm x 265 mm x 286 mm
Net Weight 34 kg

Connections and Interfaces

Terminal Block Signal / Circuit Assignment
U1, V1, W1 3-Phase Mains Input Voltage Supply
U2, V2, W2 3-Phase Output to AC Induction Motor
UDC+, UDC- Intermediate DC Link Terminals (Dynamic Braking / Common DC Bus)
X21 (RMIO) Analog Inputs (AI1, AI2) and Programmable Analog Outputs
X22 (RMIO) Programmable Digital Inputs (DI1 to DI6) and 24 V DC Auxiliary Supply
X23, X25, X26 Programmable Relay Outputs (RO1, RO2, RO3) for status signaling

Empirical Engineering Insights

Alternative Models & Compatibility

The ACS800-01 standard wall-mounted drive utilizes the RMIO (Motor Control and I/O) board. When replacing older units, verify the firmware revision loaded on the RMIO card (such as Standard Control Program ASXR7xxx). For systems operating under master-follower configuration or DSU control, the specific firmware parameters must match exactly. While the newer ACS880 series is the general migration path, the ACS800-01-0050-3 continues to be a drop-in replacement, avoiding control network redesigns in systems utilizing older DDCS fiber-optic networks.

Application Pitfalls & Engineering Notes

For Frame Size R5 wall installations, dynamic ventilation is critical. The drive dissipates a significant amount of heat at full output. Ensure at least 200 mm of clear space above and below the cooling fan assembly. If mounting inside an enclosure, verify that the cabinet cooling capacity can offset the internal heat loss. Avoid placing the drive in high-humidity or highly conductive dust environments without adequate secondary containment, as conductive particles can cause immediate short circuits across the DC bus capacitors.

Commissioning & Wiring Tips

During commissioning, performing an ID Run (Identification Run) is vital for Direct Torque Control accuracy. If the application allows, decouple the motor from the load to perform a "Standard ID Run." If uncoupling is impossible, use the "Reduced ID Run" or "ID Run Still" parameters to map the motor stator resistance accurately. Ensure 360-degree grounding of the motor cable shields at the gland plate to suppress high-frequency electromagnetic interference (EMI) that can disrupt sensitive local analog sensors.

Installation Guidelines

CRITICAL WARNING

Before beginning any installation, maintenance, or terminal wiring procedures, isolate the input power supply from the drive. Wait a minimum of 5 minutes after disconnecting the power supply to allow the internal DC bus capacitors to discharge to safe voltage levels. Always verify with a calibrated multimeter that the voltage between UDC+ and UDC- (or UDC+ and frame ground) is below 50 V DC before making contact with terminal connections.

  1. 1
    Mechanical Mounting: Securely mount the R5 frame vertically to a flat, non-flammable wall surface using appropriate M6 heavy-duty bolts.
  2. 2
    Power Cable Routing: Connect the three-phase input mains to terminals U1, V1, and W1. Connect the shielded motor cables to U2, V2, and W2.
  3. 3
    Shielding and Grounding: Ensure a low-impedance ground connection is made between the drive's PE terminal, the motor frame, and the mains distribution board PE.
  4. 4
    Control Wiring & Configuration: Wire necessary digital and analog inputs to the RMIO block. Close the chassis cover, apply input power, and enter motor nameplate data into parameter group 99 to initiate commissioning.

What is the discharge time for the internal capacitors on this drive?

Always wait a minimum of 5 minutes after disconnecting the primary input power supply before attempting any maintenance or removing the front cover. This allows the internal DC link capacitors in the R5 frame to safely discharge below 50 V DC.

Why is performing a motor ID run necessary during commissioning?

The Direct Torque Control (DTC) architecture relies on an accurate mathematical model of the connected motor. The ID Run maps stator resistance and inductance, ensuring precise speed regulation and torque output.

Does this drive contain an integrated dynamic braking chopper?

The ACS800-01-0050-3 features connection terminals for an external brake resistor (via UDC+ and UDC-), but you must verify if the built-in brake chopper option is factory-installed on your specific unit configuration.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Swedia

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...