1 dari 6

ABB DSSR122 Advant Master Power Supply Unit

ABB DSSR122 Advant Master Power Supply Unit

Hanya 6 item tersisa di stok
  • Produsen: ABB

  • Nomor Produk: DSSR122

  • Negara asal:Swedia

  • Jenis Produk: PLC Power Supplies

  • Kode batang: 85044095

  • Pembayaran: T/T, Western Union

  • Berat: 2400g

  • Dimensi: 102 mm x 152 mm x 279 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Providing stabilized backplane logic power, the ABB DSSR122 functions as a high-capacity power supply module within the legacy Advant Master (Advant OCS) control system architecture. This module is engineered to accept a primary input range of 18V to 30V DC and convert it into a highly regulated 5V DC output rated at up to 40A. Built to withstand the electrical rigors of heavy industrial processes, the hardware delivers consistent, low-ripple power directly to the rack backplane to ensure continuous operation of processing units and communication interfaces.

Key Features

  • High Current Output: Delivers continuous 5V DC logic power at 40A to support dense multi-module configurations.
  • Wide DC Input Tolerance: Operates reliably across a fluctuating 18V to 30V DC input window, mitigating standard main-line voltage drops.
  • System Integration: Native mechanical and electrical compatibility with the ABB Advant Controller rack assemblies.
  • Rugged Enclosure: Industrial-grade metal housing designed for effective passive heat dissipation and structural protection.

Applications

  • ABB Advant Controller 410 (AC410) and Advant Controller 450 (AC450) process control stations.
  • Centralized cabinet installations requiring high-amperage 5V DC logic feeds.
  • Continuous process industries including paper mills, power generation, and chemical refinement plants.

Technical Specifications

Parameter Specification Value
Manufacturer ABB
Model Number DSSR122
Control Series Advant Master (Advant OCS)
Product Type Power Supply Unit
Input Voltage Range 18 - 30 V DC
Output Voltage 5 V DC
Output Current 40 A
Lifecycle Status Phase-Out / Legacy Spare Part
Commodity Code 85044095
Weight 2.40 kg
Dimensions (W x H x D) 102 mm x 152 mm x 279 mm

Empirical Engineering Insights

Alternative Models & Compatibility

The DSSR122 acts as a direct-replacement power assembly. Ensure that physical backplane guides and dynamic sub-rack keying elements are aligned correctly with the unit chassis prior to insertion to prevent guide-pin damage on older OCS backplanes.

Application Pitfalls & Engineering Notes

Under a full 40A load, backplane contact resistance must be minimized. Oxidation on aging rack connectors can cause high-resistance points, leading to local voltage drops and thermal stress. Clean the backplane contacts with approved non-residue contact cleaners during standard maintenance cycles.

Commissioning & Wiring Tips

To accommodate the primary input current draw under peak startup conditions, ensure that the feeding 24V DC cabling is correctly dimensioned to prevent transient voltage sags. Use multi-strand copper conductors with correct ferrule terminations at the terminal block.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all primary and secondary DC supply sources before attempting mechanical installation or removal of this unit. High-current arcing hazard exists at the backplane interfaces when mounting under live electrical loads.

1

Inspect the card-edge backplane connectors on the DSSR122 for bent contacts, debris, or dust accumulation.

2

Align the module carefully with the sub-rack card guides, pushing the assembly firmly into place until the front locking mechanism is fully engaged.

3

Connect the input wires to the designated primary power terminals, verifying correct polarity (18-30V DC input).

4

Energize the primary source and measure output logic levels at the terminal monitoring points to verify stable 5V DC delivery.

Loading product navigation…

What is the primary output rating of the DSSR122 unit?

The module delivers a stabilized 5V DC output with a maximum current rating of 40A, designed to supply logic power to the rack backplane.

What is the acceptable DC input voltage range?

The DSSR122 operates with a wide primary input range between 18V DC and 30V DC, allowing for stable operations during standard industrial supply fluctuations.

Does the DSSR122 require forced-air cooling in the panel?

The module utilizes natural convection cooling. However, users must maintain adequate vertical clearance inside the electrical cabinet to prevent excessive heat buildup under heavy loads.

Can this unit be hot-swapped while the system is under load?

No. Hot-swapping is not recommended due to high-current arcing hazards at the system backplane connectors. The primary supply must be fully de-energized before mounting or extracting.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Swedia

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...