1 dari 6

ABB FPBA-01 ACS Series PROFIBUS DP Adapter Module

ABB FPBA-01 ACS Series PROFIBUS DP Adapter Module

Hanya 4 item tersisa di stok
  • Produsen: ABB

  • Nomor Produk: FPBA-01

  • Negara asal:Swedia

  • Jenis Produk: PROFIBUS Adapter Modules

  • Kode batang: 85044095

  • Pembayaran: T/T, Western Union

  • Berat: 100g

  • Dimensi: 7.60 cm x 7.60 cm x 2.50 cm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Description

Establishing high-performance cyclic and acyclic data exchange between industrial control networks and variable speed drives, the ABB FPBA-01 PROFIBUS DP communication adapter module provides seamless integration into distributed control architectures. This interface module slides directly into the drive slot, enabling standard PROFIdrive or ABB Drives communication profiles to command, monitor, and configure parameters on compatible frequency converters. Operating with 16-bit word lengths, it ensures reliable signal transmission under demanding electromagnetic conditions typical of industrial plant floors.

Key Technical Features

  • Multi-Protocol Support: Full compliance with both PROFIBUS DP-V0 and DP-V1 standards, allowing cyclic process data exchange and acyclic parameter configuration.
  • Adaptive Baud Rate Detection: Automatically locks onto network speeds ranging from 9.6 kbit/s up to 12 Mbit/s, eliminating manual transmission rate configurations.
  • Versatile Control Profiles: Native support for the standard PROFIdrive profile as well as the proprietary ABB Drives profile for system flexibility.
  • Direct Slot Integration: Compact physical form factor designed to mount inside the drive housing, receiving internal control power directly from the host drive.

Industrial Applications

  • Continuous Process Environments: Connecting variable speed pump and fan drives in water/wastewater facilities to centralized PLCs.
  • Automated Material Handling: Synchronization of conveyor speed controllers in packaging and logistics distribution lines.
  • Machinery Manufacturing: High-density multi-axis machinery configurations using ACS355 drive blocks controlled via a centralized Siemens master controller.

Technical Specifications Table

Parameter Specification Value / Limit
Manufacturer ABB
Model Identifier FPBA-01
Internal Part Code 68469325
Host Drive Compatibility ACS355, ACS350, ACS850, ACQ810, ACS880, ACS580 Series
Communication Protocol PROFIBUS DP-V0 and DP-V1
Baud Rate Range 9.6 kbit/s to 12 Mbit/s (Auto-detecting)
Connection Interface 9-pin D-sub (female) connector
Current Consumption Max 80 mA at 24 VDC (supplied from host drive)
Commodity Code 85044095
Dimensions 7.60 cm x 7.60 cm x 2.50 cm
Net Weight 0.10 kg

Connections and Pin Assignments

The fieldbus physical layer utilizes a 9-pin Sub-D female block configured as follows:

Pin Number Signal Name Description
1 SHLD Chassis and Cable Shield Connection
3 RxD/TxD-P (B-Line) Positive Data Transmission (Red Wire)
5 DGND Data Ground (Reference potential)
6 VP +5 VDC Power supply for termination resistors
8 RxD/TxD-N (A-Line) Negative Data Transmission (Green Wire)

Empirical Engineering Insights

Alternative Models & Compatibility

The FPBA-01 acts as a universal communication adapter for multiple series of ABB drives. However, some legacy ACS350 drives require a dedicated firmware revision level to map DP-V1 acyclic blocks correctly. Check parameter group 51 (Fieldbus Parameter Group) after hardware discovery to confirm that the driver version is recognized by the VFD main board.

Application Pitfalls & Engineering Notes

A common cause of bus faults during system startups is the lack of proper network termination on physical line ends. If the FPBA-01 sits at the physical end of the PROFIBUS segment, a SUB-D connector containing integrated termination switches must be used, and the switch must be toggled to 'ON'. Ensure that this termination connector receives power from Pin 6 (+5V) and Pin 5 (DGND) on the FPBA-01 module.

Commissioning & Wiring Tips

When compiling the master PLC database, ensure the correct GSD configuration file is loaded (typically ABB_090F.GSD). After altering parameter values in Group 51, a parameter refresh is mandatory. Trigger Parameter 51.27 (FBA PAR REFRESH) or perform a complete drive power cycle to commit the node address changes to active memory.

Installation Guidelines

CRITICAL SAFETY WARNING

Ensure the host drive is fully de-energized. Wait a minimum of 5 minutes after switching off the main incoming power supply to allow the DC bus capacitors to discharge completely. Use a calibrated multimeter to confirm zero voltage at the drive terminals before inserting or removing the communication card.

1
Align the male multi-pin header on the rear of the FPBA-01 adapter with the corresponding interface option slot on the host drive control panel area.
2
Carefully press the module in place until the retaining plastic tabs engage with the drive frame to secure physical placement.
3
Tighten the integrated mounting/grounding screw to establish reliable chassis grounding and prevent vibration-induced disconnections.
4
Insert the standard 9-pin Sub-D PROFIBUS connector and secure it using the thumb screws. Route the fieldbus cable far from high-power phase wiring.
Loading product navigation…

Can the FPBA-01 module be hot-swapped while the host drive is powered?

No. Removing or inserting the module while control power is applied to the drive can permanently damage the internal interfaces of both the drive and the adapter module.

How is the PROFIBUS node address assigned for this module?

The node address is set using Group 51 parameters (specifically parameter 51.02) via the drive's control panel or drive commissioning software. Address configurations from 1 to 125 are supported.

Does the FPBA-01 require an external 24V power supply to work?

No. The module is directly powered through the drive’s internal slot connection, drawing a maximum of 80 mA of internal power.

What is the differences between DP-V0 and DP-V1 operation on the FPBA-01?

DP-V0 supports cyclic data exchange, such as control words, status words, and speed references. DP-V1 compatibility adds acyclic read/write commands, enabling advanced parameter modification directly from the PLC.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Swedia

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...