1 dari 2

ABB SF810I-LOS-UVIR-T Uvisor SF810i Multi Fuel Integrated Safe Flame Scanner

ABB SF810I-LOS-UVIR-T Uvisor SF810i Multi Fuel Integrated Safe Flame Scanner

Hanya 10 item tersisa di stok
  • Produsen: ABB

  • Nomor Produk: SF810I-LOS-UVIR-T

  • Negara asal:Tiongkok

  • Jenis Produk: Flame Scanners

  • Kode batang: 9031809090

  • Pembayaran: T/T, Western Union

  • Berat: 1372g

  • Dimensi: 180 mm x 135 mm x 260 mm (W x H x L)

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

The ABB SF810I-LOS-UVIR-T (SF810INT-LOS-UVIR-T-C-W ) is an advanced multi-fuel integrated safe flame scanner belonging to the Uvisor SF810i and Symphony Plus product families. This module acts as an integrated, self-contained intelligent combustion sensor, combining the optical detection assembly and the signal analysis processor within a single rugged enclosure. Engineered for challenging multi-fuel burners, it features dual-sensor detection capability utilizing both Ultraviolet (UV) and Infrared (IR) solid-state sensors to continuously monitor the presence or absence of individual burner flames. Beyond absolute flame discrimination, the device continuously analyzes flame modulation characteristics to compute real-time qualitative combustion stability trends. It features a Line-of-Sight (LOS) optical orientation, an internal termination board with plug-in terminal blocks, and an embedded Modbus RTU RS485 communication link for peripheral integration. Powered by a nominal 24 VDC input, the scanner operates without a separate remote evaluation unit, delivering safety-critical flame relay contacts and analog quality tracking outputs directly from the burner-mounted unit.

Features

  • Integrated all-in-one architecture housing both optical sensors and microprocessing electronics inside the burner head unit.
  • Dual solid-state UV and IR sensor arrangement designed for multi-fuel discrimination and coal, oil, or gas combustion profiling.
  • Line-of-Sight (LOS) optical orientation configuration for direct direct-view flame alignment.
  • Native electronic communication via built-in Modbus RTU over a 2-wire RS485 physical layer.
  • Direct on-board user configuration management accessible via raw Modbus registers or PC-based software utilities.
  • Internal terminal block module layout fitted with an integrated termination board for straightforward field wiring.

Applications

  • Multi-fuel utility burners using independent or simultaneous gas, oil, and pulverized coal firing.
  • Continuous flame supervision and discrimination within industrial steam boilers and power generation furnaces.
  • Real-time qualitative monitoring of flame combustion dynamics and burner performance.
  • Burner Management System (BMS) integration via direct hardwired flame safety relays.

Ordering Information

Detail Value / Description
Product ID SF810I-LOS-UVIR-T
Catalog Description SF810INT-LOS-UVIR-T-C-W
Invoice Description SF810INT-LOS-UVIR-T-C-W
Model Code Structure Integrated (SF810i), Line of Sight (LOS), UV + IR Sensors (UVIR), Terminal Block Termination (T)

Technical Specifications

Parameter Value / Specification
Manufacturer ABB
Product Family Uvisor SF810i Series (Integrated)
System Platform Symphony Plus
Sensing Technology Solid-state Ultraviolet (UV) + Infrared (IR)
Optical Configuration Line-of-Sight (LOS) / Direct View
Termination Type Plug-in terminal blocks via internal termination board
Serial Communication RS-485, 2-wire half-duplex
Communication Protocol Modbus RTU
Input Supply Voltage 24 V DC (Nominal)
Country of Origin China (CN)
Customs Tariff Number 9031809090
Product Net Width 7.087 in (180 mm)
Product Net Height 5.31 in (135 mm)
Product Net Length 10.236 in (260 mm)
Gross Weight 1.372 kg

Connections/Interfaces

Interface Option Function / Assignment
Internal Termination Board Provides plug-in screw terminal blocks for field conductor routing.
Flame Relay Contacts Independent hardwired output for direct safety-critical integration with the BMS.
Analog Output Channel Current loop configuration representing real-time flame signal quality metrics.
RS485 Serial Interface Two-wire connection supporting remote parameter alignment and diagnostic data fetch over Modbus RTU.

Installation Guidelines

  • Unscrew the housing access cover to expose the integrated internal termination board for conductor assignment.
  • Wire the power supply and communication paths to the plug-in terminal blocks, using shielded twisted-pair cables for the 2-wire RS485 Modbus network to minimize transient noise.
  • Mount the device onto the burner sight pipe via its designated Line-of-Sight mechanical flange link, aligning the assembly directly with the target primary combustion zone.
  • Apply low-pressure purging air to the cooling jacket assembly if operating in high thermal environments to protect the solid-state sensor window from soot buildup and overheating.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

ABB SF810I-LOS-UVIR-T Uvisor SF810i Multi Fuel Integrated Safe Flame Scanner

What does the integrated design approach mean for the device installation?

The integrated design combines both the optical sensor array and the signal processing board into a single enclosure, meaning no standalone remote evaluation unit or separate control cabinet module is required.

Which sensor technologies are embedded in this specific model?

The device features a dual solid-state configuration consisting of both Ultraviolet (UV) and Infrared (IR) sensors, allowing accurate flame discrimination on burners firing multiple fuel types.

How are field cables connected inside the scanner enclosure?

Field wiring is handled via an internal termination board that features plug-in terminal blocks, accessible by opening the heavy-duty housing cover.

What local data and network communication protocols does the device support?

The device provides native serial communication supporting the standard Modbus RTU protocol over a 2-wire half-duplex RS-485 interface.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Tiongkok

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...