1 dari 1

Beckhoff EP2338-0001 EtherCAT Box 8-channel Digital Input/Output Module

Beckhoff EP2338-0001 EtherCAT Box 8-channel Digital Input/Output Module

Hanya 10 item tersisa di stok
  • Produsen: BECKHOFF

  • Nomor Produk: EP2338-0001

  • Negara asal:Jerman

  • Jenis Produk: EtherCAT Box Modules

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 30 mm x 126 mm x 26.5 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Engineered for direct machine-mount deployment, the Beckhoff EP2338-0001 EtherCAT Box offers decentralized I/O processing in a robust, compact form factor. This module features 8 digital channels that are individually and freely configurable as either inputs or outputs, optimizing field-level signal distribution without requiring intermediate terminal boxes. Operating over the native EtherCAT protocol, it interfaces via shielded, screw-type M8 bus connections, ensuring high-speed data transmission and determinism in high-vibration applications. Housed in a polyamide PA6 enclosure, it provides comprehensive protection against dust, water jets, and temporary immersion, making it suitable for wet or dirty manufacturing environments.

Features

  • Configurable I/O Flexibility: 8 channels that can be dynamically designated as digital inputs (Type 1/3) or digital outputs (0.5 A per channel).
  • Ruggedized Industrial Design: Encased in PA6 polyamide housing with IP65, IP66, and IP67 ratings for wet, dusty, or washdown conditions.
  • Direct EtherCAT Bus Interface: Dual-channel M8 connection with built-in shielding to maintain signal integrity over distributed topologies.
  • Short-Circuit Protection: Individually short-circuit proof outputs with active current-limiting and automatic recovery.
  • Hazardous Location Certification: ATEX Zone 2/22 (II 3 G Ex nA IIC T4 Gc) rated for safe installation in explosive environments.

Applications

  • Decentralized conveyor control and sorting systems.
  • Automotive assembly lines and robotic end-of-arm tooling.
  • Packaging machinery requiring distributed IP67-rated sensor/actuator integration.
  • Process plants and chemical environments requiring ATEX Zone 2 field modules.

Technical Specifications

Parameter Specification Value
Manufacturer Beckhoff Automation
Model Identifier EP2338-0001
Communication Protocol EtherCAT
Number of Channels 8 digital inputs or outputs, bidirectional
Input Specification EN 61131-2, Type 1/3 (10 microsecond filter)
"0" Signal Voltage -3 to +5 V
"1" Signal Voltage 11 to 30 V (6 mA nominal current)
Sensor Supply Current Max. 0.5 A total from load supply, short-circuit proof
Nominal Load Voltage 24 V DC (-15% / +20%)
Max. Output Current 0.5 A per channel (short-circuit proof, typical 1.5 A peak limit)
Switching Delays TON: 50 microseconds (typ.), TOFF: 100 microseconds (typ.)
Current Consumption 120 mA from US (system voltage)
Electrical Isolation 500 V (channel-to-logic)
Enclosure Material Polyamide PA6
Protection Rating IP65/66/67 (conforms to EN 60529)
Operating Temperature -25 to +60 degC
Physical Dimensions 30 mm x 126 mm x 26.5 mm (W x H x D)
Net Weight 165 g
Shipping Weight (Calculated) 0.50 kg

Connections and Interfaces

Interface Connection Connector Type Configuration Detail
EtherCAT Bus Input/Output 2 x M8 socket (shielded, screw connection) Provides physical-layer uplink/downlink communication for EtherCAT frame processing.
Channel Interfaces 8 x M8 x 1, 3-pin (a-coded) Configured dynamically via controller for physical sensor or actuator connection.
Power Feed 1 x M8 male connector, 4-pin Input for system/sensor voltage (US) and actuator/load voltage (UP).
Power Downstream 1 x M8 female connector, 4-pin Provides daisy-chained supply lines for downstream EtherCAT Box nodes.

Alternative Models & Compatibility

For installations using larger cabling architectures, the EP2338-0002 features the same internal electrical logic as the EP2338-0001 but uses M12 circular connectors instead of M8. When transitioning systems from older non-EtherCAT topologies, this model directly replaces legacy Profibus or CANopen boxes. Ensure that TwinCAT 2.11 (or higher) XML configuration files are updated to map the correct hardware revision to prevent mismatch errors during system startup.

Application Pitfalls & Engineering Notes

A critical parameter during deployment is the sensor supply limit of 0.5 A total across all channels. If multiple heavy-draw inductive sensors or photo-eyes are fed from the same unit, ensure their combined quiescent and peak operational current does not exceed this limit. Overcurrent conditions will cause the sensor power rail (derived from US) to trip, resulting in field offline errors in TwinCAT. Additionally, although the outputs are protected against inductive load energy, fast-cycling inductive solenoids should be installed with external suppression elements to prolong the lifetime of the switching driver circuits.

Commissioning & Wiring Tips

Always ensure that the M8 fieldbus and power connections are torqued to the manufacturer-specified 0.4 Nm. Under-tightening compromises the IP67 moisture seal, while over-tightening can crack the polyamide housing or damage internal thread inserts. When integrating into electrically noisy environments (such as near large variable frequency drives), the mounting plate of the module should have a low-impedance ground connection. Use a serrated washer on at least one of the M3 mounting screws to bite through anodized or painted backplates and establish a reliable path to earth ground.

Installation Guidelines

CRITICAL WARNING:

De-energize all system and load power supplies (US and UP) before physically mounting or mating cables with the EtherCAT Box. Hot-plugging fieldbus or power connections in Zone 2 hazardous locations can result in electrical arcing, posing severe explosion hazards and risking immediate destruction of the unit's internal microprocessor.

1

Position the module on a flat, vibration-free surface. Mark and drill two mounting holes with a diameter of 3.5 mm to match the integrated fixing points spaced along the housing length.

2

Secure the unit using two standard M3 screws. Ensure proper grounding by establishing metallic contact between the mounting plate and the machine chassis.

3

Attach and tighten the incoming and downstream EtherCAT M8 cables. Seal unused M8 ports with protective plastic caps to maintain the IP67 ingress rating.

4

Connect the M8 auxiliary power cables, verifying that the input voltage for both US (system) and UP (actuator load) is strictly within the allowed range of 24 V DC (-15% / +20%).

Loading product navigation…

Can the individual channels of the EP2338-0001 be configured as inputs and outputs simultaneously?

Yes. Each of the 8 channels can be mapped in TwinCAT to operate either as a digital input or as a digital output. This parameterization is handled entirely via software over the EtherCAT bus without physical hardware alterations.

What is the maximum output current capacity of the EP2338-0001?

Each output channel is rated for a continuous current of 0.5 A. The outputs are short-circuit protected and capable of handling ohmic, inductive, and lamp loads.

How is the sensor supply voltage derived and protected?

The sensor supply is derived directly from the system supply voltage (US) and features a total current capacity limit of 0.5 A. It is fully short-circuit proof to protect internal module circuitry.

Does this model support hot-swapping in field installations?

No. While EtherCAT supports hot-plugging topologies, the EP2338-0001 must be de-energized prior to cable disconnection or connection, particularly when deployed in hazardous areas conforming to ATEX Zone 2 regulations.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...