1 dari 1

Bently Nevada 1900/65A-00-00-03-00-00 General Purpose Equipment Monitor

Bently Nevada 1900/65A-00-00-03-00-00 General Purpose Equipment Monitor

Hanya 2 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 1900/65A-00-00-03-00-00

  • Negara asal:Amerika Serikat

  • Jenis Produk: Machinery Protection Systems

  • Pembayaran: T/T, Western Union

  • Berat: 320g

  • Dimensi: 320 mm x 240 mm x 180 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Providing dedicated, continuous machine-level machinery protection, the Bently Nevada 1900/65A-00-00-03-00-00 functions as a rugged, standalone four-channel monitor configured for critical machinery parameters such as vibration, temperature, position, and speed. The 1900/65A series architecture integrates transducer conditioning, alarm detection, and output relays into a single, compact system. This specific variation operates on 18 to 36 Vdc power, features no local display for streamlined remote control configurations, and is safely housed inside a weatherproof Fiberglass NEMA 4X/IP66 enclosure with a clear viewing window. By combining dynamic dynamic-channel processing with static temperature inputs, it reliably monitors cooling towers, small pumps, and industrial fans without requiring a larger rack-based DCS framework.

Features

  • Four dynamic input channels compatible with acceleration, velocity, or proximity sensors.
  • Two dedicated temperature channels accepting 3-wire RTD or Type E, J, K, and T thermocouples.
  • Six configurable relay outputs (four SPDT alarm relays and two system-status relays) for direct equipment trip control.
  • Four 4-20 mA analog outputs providing continuous telemetry data to external PLCs or SCADA platforms.
  • NEMA 4X/IP66-rated fiberglass housing with a transparent door window for field monitoring in harsh environments.
  • No display configuration reduces auxiliary power requirements and prevents unauthorized field tampering.

Applications

  • Cooling tower fan gearboxes and structural vibration monitoring.
  • Industrial air compressors and processing blowers.
  • Electric motors, centrifugal pumps, and secondary water circulation loops.
  • Small-scale steam and gas turbines in cogeneration plants.

Ordering Information

Option Code Option Type Configuration Detail
1900/65A Base Model General Purpose Equipment Monitor
00 Power Option 18 to 36 Vdc
00 Display Option No local display unit
03 Mounting Option Fiberglass NEMA 4X/IP66 WP housing with window in door
00 Approvals Option No hazardous area approvals
00 Communications None (Standard Analog/Relay Interface Only)

Technical Specifications

Parameter Specification value
Supply Voltage Range 18 to 36 Vdc (24 Vdc nominal)
Power Consumption 3.0 Watts typical, 8.0 Watts maximum
Dynamic Signal Inputs 4 channels, supports Proximitor, Accelerometers, and Velomitors
Temperature Inputs 2 channels, RTD (3-wire 100 ohm Platinum) or Thermocouples (E, J, K, T)
Relay Outputs 4 programmable alarm relays, 2 system status relays (SPDT, 5 A at 250 Vac)
Analog Recorder Outputs Four 4 to 20 mA outputs (internally powered, max loop resistance 600 ohms)
Frequency Response 0.2 Hz to 20,000 Hz (sensor dependent)
Enclosure Classification NEMA 4X / IP66 Weatherproof
Operating Temperature -20 to +70 degC (-4 to +158 degF)
Net Weight 0.77 kg (1.7 lbs) (excluding enclosure)
Shipping Weight (Calculated) 2.00 kg (4.4 lbs)
Package Dimensions (Calculated) 320 mm x 240 mm x 180 mm
Manufacturer Bently Nevada (Baker Hughes)
Country of Origin United States

Connections and Interfaces

Terminal Block Pin / Designation Function / Circuit Assignment
TB1 Power (+), Power (-), GND 18-36 Vdc Power Connection & Chassis Ground
TB2 Ch 1 & Ch 2 (+ / - / S) Dynamic Transducer Inputs (Proximity / Accelerometers)
TB3 Ch 3 & Ch 4 (+ / - / S) Dynamic Transducer Inputs (Proximity / Accelerometers)
TB4 A, B, C (Ch 5 & Ch 6) RTD Leads or Thermocouple Cold Junction Inputs
TB5 Relay 1 to Relay 4 SPDT Dry Contact Alarm Interlocks

Empirical Engineering Insights

Alternative Models & Compatibility

The 1900/65A series directly replaces the older legacy 1900/65 platforms. However, configuration files created under the non-A version cannot always be uploaded directly without validation. Ensure you run Bently Nevada Configuration Software Version 1.4 or higher to translate older configuration profiles into the 1900/65A firmware structure.

Application Pitfalls & Engineering Notes

Because this model features the 00 (No Display) option, local physical troubleshooting is restricted to internal LED status indicators. For remote locations, configure the four 4-20 mA outputs to stream directly to a control room DCS to track individual sensor health and prevent blind operation. Additionally, ensure the internal NEMA 4X housing temperature does not consistently exceed 70 degC when switching inductive relay loads at maximum current limits.

Commissioning & Wiring Tips

Always isolate dynamic signal shields from structural earth at the machine end. Sensor shields must terminate strictly at the monitor's TB2 and TB3 shield contacts. Running a single-point ground layout back to the central DC common minimizes high-frequency electromagnetic noise from variable-frequency drives (VFDs) that could otherwise trigger false dynamic alerts.

Installation Guidelines

CRITICAL WARNING: Ensure all primary and auxiliary DC power sources are completely de-energized and locked out before removing the fiberglass cover or inserting wire connections. Verify that any high-voltage relay loads are fully isolated to prevent high-voltage arcing across adjacent terminals.
1

Mount the NEMA 4X fiberglass enclosure securely to a rigid, vibration-free surface using standard mounting hardware to prevent auxiliary structural vibration from corrupting dynamic channel signals.

2

Route dynamic sensor cables and power cables through separate conduit entries to avoid cross-coupling noise on sensitive transducer circuits.

3

Terminate the 18 to 36 Vdc power feeds on terminal block TB1, observing correct polarity to prevent trigger startup failure or protection loop faults.

4

Connect your configuration computer to the internal serial port using the dedicated Bently Nevada programming interface to program sensor scales, trip limits, and dynamic filtering configurations.

Loading product navigation…

Does this monitor support external Modbus communications?

No. The 1900/65A-00-00-03-00-00 has option code 00 for communications, meaning it does not contain Modbus or industrial Ethernet capabilities. It relies entirely on physical relays and four 4-20 mA analog outputs for interfacing with external control devices.

Can I run dynamic vibration sensors and temperature probes simultaneously?

Yes. It supports four dynamic channels (e.g., accelerometers, proximity probes) and two static channels (e.g., RTDs, thermocouples) concurrently, acting as an all-in-one regional machinery monitor.

What software is required to configure the 1900/65A without a display?

Configuration requires the Bently Nevada 1900 Configuration Software utility. It connects directly via a dedicated programming interface located inside the fiberglass enclosure.

Is the enclosure suitable for outdoor installations?

Yes. The fiberglass enclosure is rated NEMA 4X and IP66, which guarantees protection against rain, sleet, external ice formation, and direct water spray.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...