1 dari 3

Bently Nevada 190501-12-00-04 Velomitor CT Transduser Kecepatan

Bently Nevada 190501-12-00-04 Velomitor CT Transduser Kecepatan

Hanya 8 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 190501-12-00-04

  • Negara asal:Amerika Serikat

  • Jenis Produk: Transduser Kecepatan Velomitor CT

  • Kode batang: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 297g

  • Dimensi: 33 mm x 82 mm x 33 mm (H x W x D)

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Deskripsi

190501-12-00-04 Velomitor CT Velocity Transducer adalah sensor piezoelektrik frekuensi rendah khusus yang dirancang untuk pemantauan mesin di lingkungan industri yang menuntut. Konfigurasi ini dilengkapi dengan plate stud 3/8-in 24 ke M8x1 (Opsi 12), antarmuka koneksi standar MIL-C-5015 (Opsi 00), dan persetujuan area berbahaya lengkap termasuk CSA, ATEX, dan IECEx (Opsi 04).

Dirancang terutama untuk rakitan kipas menara pendingin dan penukar panas yang didinginkan udara yang beroperasi pada atau di atas 90 rpm, transduser ini memberikan pengukuran kecepatan getaran casing yang andal. Perangkat ini dibuat dengan rumah stainless steel 316L dan elektronik internal yang terisolasi dari casing, memastikan perlindungan kuat terhadap faktor lingkungan dan gangguan elektromagnetik. Ia mampu mengidentifikasi kerusakan mesin umum seperti ketidakseimbangan dan kesalahan penyelarasan dengan memantau frekuensi getaran yang dihasilkan oleh motor kipas dan pengurang kecepatan.

Fitur

  • Perangkat pemasangan Opsi 12: Plate stud 3/8-in 24 ke M8x1
  • Koneksi Opsi 00: antarmuka koneksi MIL-C-5015
  • Persetujuan area berbahaya Opsi 04: CSA, ATEX, IECEx, dan sertifikasi Class I, Div 1 / Zone 0/1
  • Rentang suhu operasi: -40 °C hingga +85 °C (-40 °F hingga +185 °F)
  • Pemantauan getaran frekuensi rendah (respon frekuensi 1,5 Hz hingga 1,0 kHz)
  • Bahan casing: stainless steel 316L
  • Isolasi: elektronik internal terisolasi dari casing

Aplikasi

  • Rakitan kipas menara pendingin
  • Penukar panas yang didinginkan udara
  • Pengurang kecepatan peralatan rotary
  • Pemantauan getaran casing untuk tujuan umum
  • Perlindungan mesin kipas dan blower industri

Informasi Pemesanan

Opsi Kode pada SKU Ini Deskripsi
Nomor Bagian yang Dapat Dipesan 190501-12-00-04 Velomitor CT Velocity Transducer
A - Perangkat Pemasangan 12 Plate Stud 3/8-in 24 ke M8x1
B - Koneksi 00 Antarmuka koneksi MIL-C-5015
C - Persetujuan Badan 04 CSA, ATEX, IECEx (Class I, Division 1 / Zone 0/1)

Spesifikasi Teknis

Sensitivitas 3,94 mV/mm/s (100 mV/in/s) +/- 5%
Respon Frekuensi 3,0 Hz hingga 900 Hz +/- 1,0 dB; 1,5 Hz hingga 1,0 kHz +/- 3,0 dB
Rentang Kecepatan 63,5 mm/s pk (2,5 in/s pk)
Suhu Operasi -40 °C hingga +85 °C (-40 °F hingga +185 °F)
Suhu Penyimpanan -40 °C hingga +100 °C (-40 °F hingga +212 °F)
Bahan Casing Stainless steel 316L
Konektor 2-pin stainless steel 316L MIL-C-5015, keluaran atas
Berat <297 g (10,5 oz) tipikal
Torsi Pemasangan 4,5 N-m +/- 0,6 N-m (40 in-lbf +/- 5 in-lbf)
Batas Kejut 5000 g pk, maksimum

Panduan Instalasi

Pasang transduser pada rumah bantalan atau casing mesin. Persiapan permukaan yang tepat sangat penting untuk menjaga respon frekuensi. Amankan transduser menggunakan plate stud yang disediakan, pastikan torsi pemasangan diterapkan dengan benar (4,5 N-m). Selalu pastikan kabel terlindung dan dipasang jauh dari jalur tegangan tinggi untuk mencegah gangguan sinyal. Rujuk manual instalasi mesin spesifik dan Panduan Pengguna Velomitor CT (dokumen 125389) untuk orientasi pemasangan dan praktik grounding.

Kepatuhan dan Sertifikasi

  • CE: Direktif EMC 2014/30/EU
  • RoHS: Direktif RoHS 2011/65/EU
  • Area Berbahaya: CSA/NRTL/C (Class I, Division 1), ATEX/IECEx (Zone 0/1)
  • FCC Bagian 15
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 190501-12-00-04 Velomitor CT Transduser Kecepatan

What does the '12' option code represent in this 190501-12-00-04 SKU?

The '12' code indicates a Plate Stud 3/8-in 24 to M8x1 mounting hardware configuration.

Is this Velomitor CT transducer suitable for use in hazardous areas?

Yes, the '04' approval option signifies that this specific unit carries CSA, ATEX, and IECEx certifications for use in hazardous environments, including Class I, Division 1 and Zone 0/1 areas.

What connector type is used on this transducer?

This unit uses the standard MIL-C-5015, 2-pin 316L stainless steel connection interface, as specified by the '00' connection option.

What is the primary application for the Velomitor CT transducer?

The Velomitor CT is specifically designed to measure casing vibration velocity on cooling tower and air-cooled heat-exchanger fan assemblies that operate at or above 90 rpm.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Mengapa Data Pemeliharaan Penting untuk Keandalan Industri

Data pemeliharaan menghubungkan perintah kerja, sinyal sensor, riwayat aset, biaya, dan pengetahuan teknisi. Jika digunakan dengan baik, data ini meningkatkan perencanaan, keandalan, pemeliharaan...

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman PLC FBD: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...