1 dari 1

Bently Nevada 330103-00-02-10-02-CN 3300 XL 8 mm Proximity Probe

Bently Nevada 330103-00-02-10-02-CN 3300 XL 8 mm Proximity Probe

Hanya 4 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 330103-00-02-10-02-CN

  • Negara asal:Amerika Serikat

  • Jenis Produk: Proximity Probes

  • Pembayaran: T/T, Western Union

  • Berat: 320g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Engineered for critical machinery protection and condition monitoring systems, the Bently Nevada 330103-00-02-10-02-CN operates as a non-contacting transducer designed to measure static and dynamic shaft displacement. This 3300 XL 8 mm series probe delivers high-accuracy eddy current measurements, providing vital physical gap telemetry to Proximitor sensors in high-velocity steam turbines, compressors, and industrial pumps. Incorporating a specialized ClickLoc connector and robust physical armor options, this configuration ensures reliable signal transmission in demanding, high-temperature industrial environments.

Features

  • High-System Interchangeability: Fully compatible with standard Bently Nevada 3300 XL 8 mm series Proximitor sensors and extension cables without requiring individual recalibration.
  • ClickLoc Coaxial Connection: Equipped with a miniature coaxial ClickLoc connector to resist physical disconnection and environmental ingress at critical junction points.
  • Chemical and Moisture Resistance: Designed to withstand exposure to corrosive lubricating oils, process fluids, and harsh industrial cleaning agents.
  • Precision Tip Construction: Features an 8 mm probe tip engineered for thermal stability and high-linearity measurement output.

Applications

  • Turbine Generator Sets: Real-time monitoring of radial vibration and axial thrust position in heavy-duty utility steam and gas turbines.
  • Process Compressors: Shaft centerline and oil-film bearing displacement tracking in centrifugal and reciprocating gas compressors.
  • Industrial Gearboxes: Early detection of shaft misalignment and gear mesh wear through sub-micron shaft motion analysis.
  • High-Speed Pumps: Continuous rotor dynamics feedback for critical boiler feed pumps and fluid processing machinery.

Ordering Information

Option Code Configuration Detail Value / Dimension
00 Unthreaded Length 0 mm
02 Overall Case Length 20 mm
10 Total Length 1.0 meter (3.3 feet)
02 Connector and Cable Type Miniature coaxial ClickLoc connector, standard cable
CN Agency Approval Country-specific approvals (China/CN)

Technical Specifications

Manufacturer Bently Nevada (Baker Hughes)
Model Code 330103-00-02-10-02-CN
Probe Tip Diameter 8 mm
System Linear Range 2.0 mm (80 mils) nominal (starting at 0.25 mm/10 mils offset)
Nominal Scale Factor 7.87 V/mm (200 mV/mil) when integrated into full 3300 XL system
Operating Temperature Range -51 degC to +177 degC (-60 degF to +350 degF)
Connector Material Gold-plated brass with ClickLoc quick-lock connection
Country of Origin United States (U.S.A.)
Shipping Weight (Calculated) 1.5 kg (3.3 lbs) package weight

Empirical Engineering Insights

Alternative Models & Compatibility

While the 3300 XL 8 mm proximity probe system retains backward mechanical compatibility with standard 3300 series 5 mm and 8 mm components, combining XL and non-XL systems will alter the calibrated scale factor. For optimal calibration stability and linear output, ensure that this 1.0-meter probe is paired with a corresponding 3300 XL 8 mm Proximitor sensor and a total-system-length matching extension cable (yielding either 5.0m or 9.0m total system loop configurations).

Application Pitfalls & Engineering Notes

When deploying the unthreaded (00) option, ensure the mounting clamp or sleeve provides sufficient structural rigidity to prevent probe displacement under high-vibration conditions. Observe strict side-clearance tolerances: a minimum of 15 mm of flat target area diameter is required directly in front of the 8 mm tip to prevent target-fringe inaccuracies. Avoid routing the coaxial signal cable alongside high-power AC motor or variable speed drive (VSD) supply lines to minimize magnetic cross-talk and EMI induction.

Commissioning & Wiring Tips

Before mating the miniature ClickLoc coaxial connector, verify both contacts are free of moisture, lubricating oil, and particulate debris. Use dedicated coaxial connector silicone boots or sealing kits at joint interfaces in environments containing high humidity or aerosolized process fluids. Always verify the overall system loop resistance and insulation resistance to ground before connecting the circuit back to the local Proximitor terminal block.

Installation Guidelines

CRITICAL WARNING: SAFETY INSTRUCTIONS

De-energize all machinery and power circuits before installing or adjusting proximity probes. Failure to physically isolate equipment from rotational power sources can cause severe injury or equipment destruction. Ensure localized environments match hazardous area certification classifications specified by the "CN" suffix documentation before physical installation.

1

Inspect the shaft surface target area. Ensure it is free of physical scratches, burrs, or electromagnetic runout markings that could distort displacement signals.

2

Mount the probe using a precision sleeve or bracket, ensuring the unthreaded 20 mm case length aligns correctly within the installation bore.

3

Apply a digital voltmeter (DVM) to the Proximitor monitor output terminals to monitor gap voltage during manual insertion. Position the probe to yield a -10.0 Vdc bias reading (center of linear range) before securing physical locknuts.

4

Route and anchor the 1.0-meter probe cable through dedicated protective conduit, observing minimum bend-radius specifications of 25.4 mm (1.0 inch).

Loading product navigation…

What does the 'CN' suffix denote on the 330103-00-02-10-02-CN probe?

The 'CN' suffix signifies that the proximity probe is certified under country-specific hazardous area approvals for China, matching local environmental and explosion-proof regulatory frameworks.

Can this 1.0-meter probe be directly connected to a Proximitor sensor without an extension cable?

No. The total system length (typically 5.0 meters or 9.0 meters) must be matched exactly to maintain the 200 mV/mil calibration scale factor. A 1.0-meter probe requires a matching 4.0-meter or 8.0-meter extension cable.

What is the physical significance of the '00' unthreaded length option?

An option of '00' means the probe case has no unthreaded physical portion. The outer case length is fully uniform, optimizing it for installation inside specific cylindrical clamp mounts or sleeve assemblies.

How do ClickLoc connectors improve performance compared to standard coaxial connectors?

ClickLoc miniature coaxial connectors feature a robust locking mechanism that prevents physical disengagement caused by machinery vibration, while ensuring a moisture-resistant seal when properly mated.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...