1 dari 3

Bently Nevada 330103-10-15-10-02-05 3300 XL 8 mm Proximity Probe

Bently Nevada 330103-10-15-10-02-05 3300 XL 8 mm Proximity Probe

Hanya 7 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 330103-10-15-10-02-05

  • Negara asal:Amerika Serikat

  • Jenis Produk: 3300 XL 8 mm Proximity Probe

  • Kode batang: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 150g

  • Dimensi: 150 mm x 150 mm x 30 mm (H x W x D)

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Option 10 (100 mm unthreaded length) and Option 15 (150 mm overall case length) specify this 3300 XL 8 mm proximity probe configuration — 330103-10-15-10-02-05. This metric-threaded, non-armored probe is manufactured by Bently Nevada and features an M10 x 1 thread layout. It is equipped with a 1.0 m total cable length (Option 10) terminated in a standard miniature coaxial ClickLoc connector (Option 02) and comes certified with hazardous area agency approvals (Option 05).

In contrast to standard 3/8-24 UNF threaded variants (such as the 330101 series) or armored metric configurations (such as the 330104 series), the 330103 series provides unarmored, threaded metric mounting for installations requiring an M10 x 1 thread pitch. The lack of mechanical armor reduces the outer diameter of the lead cable to 3.68 mm, facilitating simplified routing through standard conduits and tight bends inside machinery housings. This probe operates as a non-contacting transducer, generating an eddy-current field to measure dynamic shaft vibration, axial position, and speed relative to a target surface.

Features

  • M10 x 1 metric thread configuration without protective stainless steel armor.
  • 100 mm unthreaded length (Option A: 10) provides clear mounting offset.
  • 150 mm overall case length (Option B: 15) allows deep reach into machine housings.
  • 1.0 meter total lead length (Option C: 10) for direct connection to extension cables.
  • Miniature coaxial ClickLoc connector (Option D: 02) with a gold-plated termination interface.
  • Agency Approval Option 05 offers CSA, ATEX, and IECEx approvals for hazardous areas.
  • Hermetically sealed tip constructed of polyphenylene sulfide (PPS) high-performance plastic.

Applications

  • Radial shaft vibration measurements on fluid-film bearing machines.
  • Thrust/axial rotor position monitoring on high-speed industrial compressors, turbines, and pumps.
  • Eccentricity and phase reference (Keyphasor) monitoring.
  • Hazardous area machinery protection environments requiring intrinsic safety certifications.

Ordering Information

Option Segment Code Value on This SKU Meaning / Specification
Orderable Part Number 330103-10-15-10-02-05 3300 XL 8 mm Proximity Probe, M10 x 1 thread, without armor
A: Unthreaded Length Option 10 100 mm unthreaded length
B: Overall Case Length Option 15 150 mm overall case length
C: Total Length Option 10 1.0 meter (3.3 feet) total lead length
D: Connector and Cable-Type Option 02 Miniature ClickLoc coaxial connector, standard cable
E: Agency Approval Option 05 CSA, ATEX, and IECEx Approvals

Technical Specifications

Manufacturer Bently Nevada (Baker Hughes)
Part Number / Model 330103-10-15-10-02-05
Probe Tip Diameter 8.0 mm (0.31 in)
Case Thread Size M10 x 1
Unthreaded Length 100 mm
Overall Case Length 150 mm
Total Length 1.0 meter (3.3 feet)
Armor Option None (without armor)
Connector Type Miniature male coaxial ClickLoc connector
Cable Type Standard coaxial cable (75 ohm impedance, FEP jacket)
Operating Temperature -52 degC to +177 degC (-62 degF to +350 degF)
Nominal Probe DC Resistance 7.59 ohms +/- 0.50 ohms (center conductor to outer shield)
Maximum Thread Engagement 15 mm
Probe Pressure Seal Designed to withstand differential pressure up to 7.0 bar (100 psi)
System Compatibility Pairs with 3300 XL standard extension cables and 3300 XL Proximitor sensors
Dimensions 150 mm x 150 mm x 30 mm (H x W x D) (packaged envelope)
Weight 0.15 kg

Connections and Interfaces

Connector Component Function / Signal Assignment
Center Conductor RF Probe Signal / Negative DC Bias Voltage
Outer Shield Signal Common / Ground Reference

Installation Guidelines

  • Do not exceed the maximum thread engagement length of 15 mm to prevent thread binding or internal case damage.
  • Ensure a minimum target clearance of 40 mm around the 8 mm probe tip from adjacent structural metals to avoid side-view calibration offsets.
  • Hand-tighten the miniature coaxial ClickLoc connector until an audible "click" is felt; do not use pliers on the gold connector sleeves unless explicitly required by system tooling.
  • Observe minimum bend radius of 25.4 mm (1.0 in) for standard coaxial cables during routing.

Compliance and Certifications

  • CSA Class I, Division 1, Groups A, B, C, and D
  • ATEX Zone 0/1, Ex ia IIC T1...T5 Ga/Gb
  • IECEx intrinsic safety approvals
  • CE Compliant
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330103-10-15-10-02-05 3300 XL 8 mm Proximity Probe

What does the 330103-10-15-10-02-05 SKU code define?

This specific SKU defines a Bently Nevada 3300 XL 8 mm proximity probe with an M10 x 1 metric thread (without armor), a 100 mm unthreaded length (Option 10), a 150 mm overall case length (Option 15), a 1.0 meter total lead length (Option 10), a miniature coaxial ClickLoc connector (Option 02), and CSA/ATEX/IECEx hazardous area agency approvals (Option 05).

Is this 330103 proximity probe armored?

No, the 330103 series specifies a proximity probe configuration without mechanical armor over the coaxial lead cable, allowing for easier routing in tight conduits.

What is the maximum thread engagement limit for this probe?

The maximum thread engagement length for this M10 x 1 threaded probe is 15 mm. Exceeding this limit may cause binding during installation.

What is the nominal DC resistance of the 1.0 meter probe cable?

The nominal probe DC resistance measured from the center conductor to the outer conductor is 7.59 ohms +/- 0.50 ohms for this 1.0 meter total length option.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan untuk Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...