Description

330105-02-12-05-02-00: 3300 XL 8 mm reverse mount proximity probe configured with a 3/8-24 UNF threaded case, 0.2 inches of unthreaded length, and a 1.2-inch overall case length. Option 05 defines the 0.5-meter (1.6 feet) total integrated cable length, which terminates in a standard miniature coaxial ClickLoc connector (Option 02) without requiring agency approvals (Option 00).

Unlike standard proximity probes with front-facing mounting threads, reverse mount configurations are installed through the reverse side of a housing or mounting sleeve, making them suitable for specialized machinery enclosures. This model employs standard coaxial cabling rather than armored options, making it suitable for installations that utilize protective conduits or external sleeves. The 0.5-meter integrated cable length requires an extension cable to complete a standard 5-meter or 9-meter transducer system loop connected to a 3300 XL Proximitor sensor.

Features

  • Option 02 unthreaded length provides a compact 0.2-inch nose clearance for flush installations.
  • Option 12 overall case length provides a 1.2-inch physical body size with 3/8-24 UNF-2A threads.
  • Option 05 specifies an integrated 0.5-meter (1.6 feet) probe cable length.
  • Option 02 ClickLoc coaxial connector features gold plating and a locking mechanism.
  • Option 00 specifies standard build specifications without hazardous area approval marks.
  • 8.0 mm tip diameter with PPS (polyphenylene sulfide) tip material for high mechanical stability.
  • Operating temperature range of -52 degC to +177 degC (-62 degF to +350 degF) for harsh industrial environments.
  • Compatible with 3300 XL 5-meter and 9-meter Proximitor sensor systems.

Applications

Reverse mount probes are typically applied where space constraints prevent external probe mounting or where a protective housing sleeve is used. Common applications include:

  • Shaft vibration and axial position monitoring in steam or gas turbines, centrifugal compressors, and electric motors.
  • Fluid-film bearing clearance measurements in heavy rotating industrial machinery.
  • Hydrocarbon pumps, gearboxes, and generators operating in industrial environments.

Ordering Information

Option / Segment Code on This SKU Meaning / Configuration
Orderable Part Number 330105-02-12-05-02-00 3300 XL 8 mm Reverse Mount Proximity Probe, 3/8-24 UNF threads
A: Unthreaded Length Option 02 0.2 in (5.1 mm)
B: Overall Case Length Option 12 1.2 in (30.5 mm)
C: Total Length Option 05 0.5 meter (1.6 feet)
D: Connector and Cable-Type Option 02 Miniature coaxial ClickLoc connector, standard cable
E: Agency Approval Option 00 Not required / No approvals

Technical Specifications

Specification Parameter Value / Details
Manufacturer Bently Nevada (Baker Hughes)
Part Number / Model 330105-02-12-05-02-00
Transducer Family 3300 XL 8 mm Proximity Transducer System
Probe Design Reverse Mount
Case Thread Size 3/8-24 UNF-2A threads
Unthreaded Length 0.2 in (5.1 mm)
Case Length 1.2 in (30.5 mm)
Total Probe Length 0.5 meter (1.6 feet)
Cable Type 75 ohm standard coaxial cable (non-armored)
Connector Type Miniature ClickLoc coaxial male connector
Agency Approvals Not required / None configured (Option 00)
Probe Tip Diameter 8.0 mm (0.31 in)
Tip Material Polyphenylene sulfide (PPS)
Case Material AISI 303 stainless steel (S30300)
Connector Material Gold-plated brass
Operating Temperature -52 degC to +177 degC (-62 degF to +350 degF)
Pressure Seal Rating Up to 7.0 bar (100 psi) differential pressure
Dimensions (packaged) 150 mm x 150 mm x 30 mm (H x W x D)
Weight 0.12 kg

Connections and Interfaces

Connection Component Description
Center Pin (Coaxial male) RF Signal (transmits high-frequency eddy-current carrier signal)
Outer Ring / Shield Common return path and shield ground

Installation Guidelines

  • Mounting Casing: Reverse mount probes are installed through the reverse end of a housing sleeve. Ensure the lock nut is tightened securely. Do not exceed the maximum thread engagement length of 0.563 inches to prevent binding.
  • Probe Gapping: Set the nominal target gap using a caliper or by monitoring the Proximitor sensor output. Standard gap is typically 1.27 mm (50 mils) to 2.0 mm (80 mils).
  • Connector Handling: Connection between the probe and extension cable ClickLoc connectors must be finger tight. Avoid over-tightening with metal pliers unless using standard non-XL stainless steel connectors, which require an extra 1/8 turn.
  • Cable Routing: Route the coaxial cable avoiding sharp bends. Maintain a minimum bend radius of 25.4 mm (1.0 inch) for standard cables to avoid attenuation or signal distortion. Prevent cable contact with abrasive rotating components.
  • Moisture and Dirt Protection: Use appropriate silicone tape or connector protectors when the connection is exposed to high humidity, moisture, or oil spray.

Compliance and Certifications

This probe configuration is manufactured under ISO 9001 quality management standards and is suitable for general-purpose applications where hazardous area certifications are not required.

Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330105-02-12-05-02-00 3300 XL Reverse Mount Proximity Probe

What does the specific configuration code 330105-02-12-05-02-00 represent?

This specific orderable number designates a 3300 XL 8 mm reverse mount proximity probe with a 0.2-inch unthreaded length, a 1.2-inch case length, a 0.5-meter (1.6 feet) total integrated cable, a standard miniature coaxial ClickLoc connector, and no hazardous area approvals.

Why is the FluidLoc option not utilized on this variant?

The FluidLoc cable is designated under Option 12 for the connector/cable type. This configuration uses Option 02, which is the standard coaxial ClickLoc cable. For reverse mount installations, a FluidLoc option is generally unnecessary because the probe is housed within a protective outer sleeve.

Can I connect this 0.5-meter probe directly to a Proximitor sensor?

No, standard 3300 XL transducer loops require a total length of 5.0 meters or 9.0 meters. A 0.5-meter probe (Option 05) must be paired with a matching 4.5-meter or 8.5-meter extension cable (such as standard extension cable 330130) to interface with the Proximitor sensor.

What is the mechanical difference of a reverse mount probe?

Unlike standard proximity probes that screw into a threaded hole from the outside, the reverse mount probe body has threads designed for insertion from the inside or rear of a mounting adapter or sleeve, leaving the cable and connector protected inside the enclosure or housing.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan untuk Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...