1 dari 1

Bently Nevada 330193-00-02-10-00 3300 XL 8 mm ETR Proximity Probe

Bently Nevada 330193-00-02-10-00 3300 XL 8 mm ETR Proximity Probe

Hanya 7 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 330193-00-02-10-00

  • Negara asal:Amerika Serikat

  • Jenis Produk: Proximity Probes

  • Pembayaran: T/T, Western Union

  • Berat: 320g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

As a critical component in machinery protection systems, the Bently Nevada 330193-00-02-10-00 provides precise, non-contact displacement and vibration measurements under challenging thermal conditions. Engineered specifically for the 3300 XL 8 mm Extended Temperature Range (ETR) series, this proximity probe operates reliably in extreme high-temperature environments where standard sensors degrade. The system utilizes Eddy Current technology to monitor key mechanical parameters, including shaft vibration, radial position, and thrust position on critical rotating machinery.

Features

  • Extended Temperature Range (ETR): Built to endure higher temperature cycles without sacrificing signal stability or accuracy.
  • 8 mm Tip Diameter: Optimized sensor head geometry for standard high-resolution proximity measurements.
  • Unthreaded Length Option (00): Configured with 0 mm unthreaded portion for specialized low-profile mounting profiles.
  • Overall Case Length Option (02): Features a compact 20 mm case length for integration into standard probe holders and housings.
  • Total Length Option (10): Equipped with a 1.0-metre (3.3 feet) integrated cable, ideal for direct coupling to connection boxes.
  • Gold-Plated Click-Loc Connectors: Corrosion-resistant termination ensuring high-signal integrity and vibration-resistant physical connections.

Applications

  • Steam and Gas Turbines: Monitoring shaft alignment and dynamic vibration levels in high-temperature zones.
  • Industrial Compressors: Radial and axial shaft displacement tracking on high-pressure casing designs.
  • Boiler Feed Pumps: Continuous health diagnostics in high thermal cycling and fluid-intensive operations.
  • Heavy-Duty Fans & Blowers: Real-time unbalance detection in power generation and petrochemical plants.

Ordering Information

Option Code Configuration Parameter Value / Description
00 Unthreaded Length 0 mm
02 Overall Case Length 20 mm
10 Total Length 1.0 metre (3.3 feet)
00 Agency Approval Not required

Technical Specifications

Manufacturer Bently Nevada
Part Number / SKU 330193-00-02-10-00
Product Series 3300 XL 8 mm ETR
Tip Diameter 8 mm
Case Thread Option Unthreaded (0 mm length)
Physical Case Length 20 mm
Integrated Cable Length 1.0 metre
Connector Style Miniature coaxial Click-Loc
Sensor Type Eddy Current Proximity Probe
Country of Origin USA
Shipping Weight (Calculated) 1.5 kg (3.3 lbs)

Connections and Interfaces

Connector Element Type Functional Assignment / Requirements
Coaxial Center Pin Signal / High-Frequency RF Carries RF excitation signal from Proximitor Sensor and returns modulated voltage.
Coaxial Outer Shield Return Path / Common Establishes reference ground path. Must remain isolated from machine ground.
Click-Lock Joint Mechanical Coupler Locking mechanism. Requires connector protectors if exposed to fluids or oil.

Empirical Engineering Insights

Alternative Models & Compatibility

The 330193-00-02-10-00 probe is strictly designed for integration within the 3300 XL 8 mm Extended Temperature Range system. It must be paired with an ETR extension cable and an ETR-compatible Proximitor Sensor. Mismatching this probe with standard, non-ETR 3300 XL extension cables or Proximitor Sensors introduces substantial linearity deviations and calibration shifts, rendering scale factors unreliable.

Application Pitfalls & Engineering Notes

When deploying the probe in high-temperature fluid boundaries, assure that the probe case thread interface is securely sealed. Since this unit features a 0 mm unthreaded portion, the case body is fully threaded up to the tip, demanding careful depth calculation within the bracket to prevent internal mechanical interference with the target shaft.

Commissioning & Wiring Tips

Always check the insulation resistance of the probe before and after installation to confirm that the sensor tip and the coaxial shield have not shorted directly to the machine casing. Connectors must be finger-tightened until the positive Click-Loc detent engages. Do not use pliers or heavy wrenches, as excessive torque will damage the internal coaxial termination.

Installation Guidelines

CRITICAL WARNING: Prior to probe installation or physical adjustment, fully de-energize and lock out all machinery. High-speed shaft rotation can cause catastrophic mechanical impact with the probe tip if clearance parameters are set incorrectly. Use calibrated non-magnetic feeler gauges or electric micrometer spindles to verify structural clearances before starting the system.
1
Calculate the required insertion depth based on the machine housing layout and the 20 mm overall case length.
2
Slowly thread the probe into the mounting bracket or sleeve, monitoring gap voltage using a digital multimeter connected to the Proximitor Sensor output.
3
Adjust the probe body until the output reads the nominal gap voltage specified by your monitoring system (typically -10.0 VDC for standard midrange calibration).
4
Secure the probe outer locknut to lock the assembly in place, then re-verify the static gap voltage to ensure the probe did not rotate during tightening.
Loading product navigation…

What does the ETR designation mean for the 330193-00-02-10-00 probe?

ETR stands for Extended Temperature Range. It indicates that the probe is engineered with advanced insulation and materials capable of withstanding higher temperatures and wider thermal cycles than standard proximity probes without losing structural integrity or signal accuracy.

Can I use standard 3300 XL cables with this ETR series probe?

No. To maintain system accuracy and temperature rating, you must pair the 330193-00-02-10-00 probe with a matching 3300 XL ETR extension cable. Intermixing standard and ETR components degrades calibration linearity.

What physical mounting configuration does the 00 unthreaded option represent?

The '00' unthreaded length option indicates that the probe case is fully threaded along its entire length, with 0 mm of smooth shaft. This configuration is typically used in thin-walled housings or specialized mounting blocks.

Is an external terminal block required for connecting this probe?

No. The probe features an integrated 1.0-metre cable terminated with a miniature coaxial Click-Loc connector, which connects directly to a compatible extension cable running to the Proximitor Sensor.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...