1 dari 1

Bently Nevada 330195-02-12-90-CN 3300 XL 8 mm Extension Cable

Bently Nevada 330195-02-12-90-CN 3300 XL 8 mm Extension Cable

Hanya 2 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 330195-02-12-90-CN

  • Negara asal:Amerika Serikat

  • Jenis Produk: Vibration Monitoring Extension Cables

  • Pembayaran: T/T, Western Union

  • Berat: 320g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Optimized for demanding machinery protection applications, the Bently Nevada 330195-02-12-90-CN functions as a high-performance 3300 XL 8 mm Extension Cable within the standard eddy current transducer system. This cable bridges the physical distance between the proximity probe and the Proximitor sensor, ensuring precise capacitive and inductive matching necessary for accurate vibration and shaft position measurements. Featuring FluidLoc technology and an integrated connector protector, this model is specifically engineered to resist process fluid migration and mechanical stress in harsh industrial environments, while carrying the necessary regional certification approvals.

Features

  • FluidLoc Cable Design: Prevents the leakage of oil, water, or other process fluids through the inner core of the coaxial cable.
  • Connector Protector: Provides robust mechanical shielding and environmental sealing at the critical probe-to-extension-cable junction.
  • Precision Coaxial Shielding: Minimizes electromagnetic interference (EMI) and radio frequency interference (RFI) to maintain signal integrity over the entire length.
  • High Temperature Stability: Constructed with materials designed to withstand extreme temperature fluctuations within industrial casings.
  • Certified Design: Designed with the CN option, meeting regional compliance and hazardous area standards.

Applications

  • Steam and gas turbine shaft vibration and axial displacement monitoring.
  • Centrifugal compressor and high-pressure pump shaft dynamic motion analysis.
  • Hydroelectric generator thrust collar and guide bearing monitoring.
  • Heavy industrial gearbox shaft thrust and radial position tracking.

Technical Specifications

Manufacturer Bently Nevada
Model Number 330195-02-12-90-CN
Product Series 3300 XL 8 mm Proximity Transducer System
Cable Length 2.0 meters (6.6 feet)
Total System Length Compatibility 9.0 meters (29.5 feet)
Cable Configuration Option FluidLoc Cable with Connector Protector
Agency Approvals CN Option (Country-specific approvals / hazardous area certifications)
Operating Temperature Range -51 degC to +177 degC (-60 degF to +350 degF)
Nominal Impedance 75 ohms
Country of Origin United States (U.S.A.)
Shipping Weight (Calculated) 1.5 kg (3.3 lbs)

Connections and Interfaces

Connection Port Connector Type Protective Feature
Probe Interface Miniature Coaxial Male Integrated Connector Protector installed
Proximitor Sensor Interface Miniature Coaxial Female Standard silicon protective boot compatible

Empirical Engineering Insights

Alternative Models & Compatibility: The 330195-02-12-90-CN is strictly calibrated for 9.0-meter system configurations. It cannot be combined with a 5.0-meter Proximitor sensor or 5.0-meter probe configurations. Mismatching system lengths alters the total electrical capacitance of the sensor loop, leading to severe measurement non-linearity, gain errors, and invalid machinery protection alarms.

Application Pitfalls & Engineering Notes: When routing the extension cable, mechanical protection is paramount. Maintain a minimum bend radius of 25.4 mm (1.0 inch). Kinking or flattening the cable distorts the coaxial spacing between the center conductor and the outer shield, changing the characteristic impedance from 75 ohms and introducing high-frequency noise spikes that can be misidentified as machine vibration.

Commissioning & Wiring Tips: Ensure that the miniature coaxial connectors are completely clean and dry before mating. Moisture or particulate ingress inside the connector creates a high-resistance parallel path to ground, generating a drift in the gap voltage and triggering sensor fault codes in the 3500 rack. The FluidLoc and connector protector features must be correctly engaged and sealed during the final layout.

Installation Guidelines

CRITICAL WARNING

Ensure the machinery is completely de-energized, locked out, and tagged out (LOTO) prior to accessing probe housings. Discharge all residual electrostatic charges from your body and routing conduits before handling the coaxial connectors to prevent permanent electrostatic damage to the connected Proximitor sensor.

1
Route the extension cable through dedicated, grounded metal conduit. Avoid running the coaxial cable in the same cable trays or parallel paths with high-voltage AC power lines.
2
Connect the miniature coaxial interfaces carefully. Tighten the connectors to the recommended finger-tight torque. Do not use pliers or heavy tools on the miniature connectors, as this will strip the threads.
3
Slide the connector protector over the mated junction until it is firmly locked, providing mechanical and environmental sealing against steam, oil, and humidity.
Loading product navigation…

What does the -12 option signify in the 330195-02-12-90-CN model code?

The -12 option represents the FluidLoc cable configuration with an integrated connector protector. The FluidLoc technology prevents fluids from traveling inside the cable core, while the protector guards the physical coaxial joint from environmental contamination.

What is the physical length of the 330195-02-12-90-CN extension cable?

The physical cable length is 2.0 meters (6.6 feet), specified by the -02 option. The -90 option indicates it is calibrated for use in a total system length of 9.0 meters (29.5 feet).

Can I use this cable with non-XL 3300 series proximity probes?

Yes, but with limitations. While physical connections are compatible, mixing 3300 and 3300 XL components can affect system calibration parameters. For maximum accuracy and compliance, it is highly recommended to pair with other 3300 XL series components.

What are the grounding requirements for the 330195 extension cable?

The outer shield of the extension cable is electrically isolated from the machinery ground inside the conduit. System grounding must be handled solely at the Proximitor sensor side to prevent electrical ground loops that introduce signal noise.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...