Bently Nevada 330730-080-03-05 3300 XL 11 mm Extension Cable

Bently Nevada 330730-080-03-05 3300 XL 11 mm Extension Cable

Hanya 4 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 330730-080-03-05

  • Negara asal:Amerika Serikat

  • Jenis Produk: 3300 XL 11 mm Extension Cable

  • Kode batang: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 180g

  • Dimensi: 50 mm x 100 mm x 100 mm (H x W x D)

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Option 080 (8.0 meters length), Option 03 (armored cable with connector protector), and Option 05 (multiple agency approvals) specify the configuration of this 3300 XL 11 mm Extension Cable330730-080-03-05.

This cable configuration features an integrated FEP-coated stainless steel armor jacket that provides physical protection in abrasive industrial environments. The miniature coaxial ClickLoc connectors are equipped with fluorosilicone connector protectors to shield the electrical connection from moisture, dust, and turbine oil. Operating as an electrical bridge within the 3300 XL 11 mm transducer system, it provides a precise 75 ohm coaxial pathway for high-frequency signal transmission between the proximity probe and the Proximitor sensor.

Features

  • 8.0 Meter Length: Designed specifically to achieve the proper calibration distance within 9.0 meter system configurations when paired with a 1.0 meter proximity probe.
  • FEP-Coated Armor: Covered in a stainless steel armor jacket with a protective FEP outer wrap to resist mechanical wear and physical impact.
  • Connector Protectors: Pre-installed fluorosilicone boots guard male and female connections against fluid ingress and accidental disconnects.
  • Standard Coaxial Design: Features a nominal 75 ohm characteristic impedance to maintain signal integrity without attenuation or phase distortion.
  • Hazardous Area Rating: Configured with multiple global approvals suitable for deployment in zones requiring intrinsic safety or non-incendive parameters.

Applications

  • Turbine and compressor shaft vibration and axial position monitoring.
  • Ramp differential expansion measurements on industrial steam turbines.
  • Rod position or rod drop detection on reciprocating compressors.
  • Tachometer, phase reference (Keyphasor), and zero speed sensing applications.

Ordering Information

Option Segment Selected Code Description / Parameter Meaning
Base Model 330730 3300 XL 11 mm Extension Cable
A - Cable Length Option 080 8.0 meters (26.2 feet)
B - Connector and Cable Option 03 Armored cable with connector protector
C - Agency Approval Option 05 Multiple Approvals (CSA, ATEX, IECEx)

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Part Number 330730-080-03-05
Transducer System Compatibility 3300 XL 11 mm Proximity Transducer System
Total Cable Length 8.0 meters (26.2 feet)
Cable Impedance 75 ohms (nominal)
Armor Construction FEP-coated stainless steel armor
Armor Maximum Outer Diameter 7.6 mm (0.30 in)
Coaxial Cable Outer Diameter 3.7 mm (0.15 in) maximum
Connector Type Miniature coaxial ClickLoc (coaxial conductor to coaxial conductor)
Connector Material Gold-plated brass with fluorosilicone protector boot
Conductor DC Resistance (Rjacket) 2.0 +/- 0.5 ohms (coaxial conductor to coaxial conductor)
Conductor DC Resistance (Rcore) 0.6 +/- 0.2 ohms (center conductor to center conductor)
Cable Capacitance 69.9 pF/m (21.3 pF/ft) typical
Operating and Storage Temperature -52 degC to +177 degC (-62 degF to +351 degF)
Relative Humidity 100% condensing, non-submersible (when connectors are protected)
Cable Weight (Armored) 140 g/m (1.5 oz/ft)

Installation Guidelines

  • System Length Matching: Ensure that the sum of the extension cable length (8.0 meters) and the probe length (1.0 meter) matches the calibrated length of the 9.0 meter Proximitor sensor.
  • Bending Radius: Do not bend the armored cable below the recommended minimum bend radius of 30.5 mm (1.2 in) to avoid damaging the internal coaxial core.
  • Connector Handling: Keep connectors dry and clean during installation. Only use approved, residue-free contact cleaners if cleaning is necessary.
  • Connector Protection: Fully slide the pre-installed fluorosilicone connector protectors over the junction to seal it. Do not apply silicone tape if the connection will be exposed to turbine oils.

Compliance and Certifications

Certification Authority Approval Classification
ATEX / IECEx (ia) Ex ia IIC T5...T1 Ga; Ex ia IIIC T90 degC...T280 degC Dc (for EPL Dc)
ATEX / IECEx (nA, ec) Ex nA IIC T5...T1 Gc; Ex ec IIC T5...T1 Gc
North America (cNRTLus - ia) Class I, Zone 0, AEx/Ex ia IIC T5...T1 Ga; Class I, Div 1, Groups A, B, C, D; Class II, Groups E, F, G; Class III
North America (cNRTLus - nA, ec) Class I, Zone 2, AEx/Ex nA IIC T4/T5 Gc; Class I, Zone 2, AEx/Ex ec IIC T4/T5 Gc; Class I, Div 2, Groups A, B, C, D
European Directive Compliance CE Mark, EMC Directive 2014/30/EU, RoHS Directive 2011/65/EU
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330730-080-03-05 3300 XL 11 mm Extension Cable

What is the length of the Bently Nevada 330730-080-03-05 extension cable?

This extension cable is 8.0 meters (26.2 feet) long, as designated by the -080 option code.

What does the -03 option code specify on this extension cable?

The -03 option code specifies that the cable is equipped with FEP-coated stainless steel armor and includes fluorosilicone connector protectors on the miniature ClickLoc coaxial connectors.

What hazardous area ratings are included with the -05 agency approval?

The -05 option represents multiple approvals, providing certified safety compliance from ATEX, IECEx, and CSA for installation in hazardous environments.

Which probes and sensors is this 8.0-meter cable compatible with?

This cable is compatible with Bently Nevada 3300 XL 11 mm systems. It must be paired with a 1.0-meter probe to achieve the total 9.0-meter system length required by the Proximitor sensor.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan untuk Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...