1 dari 3

Bently Nevada 330881-28-11-214-00-02 PROXPAC XL Proximity Transducer

Bently Nevada 330881-28-11-214-00-02 PROXPAC XL Proximity Transducer

Hanya 6 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 330881-28-11-214-00-02

  • Negara asal:Amerika Serikat

  • Jenis Produk: PROXPAC XL Proximity Transducer

  • Kode batang: 8537101190

  • Pembayaran: T/T, Western Union

  • Berat: 250g

  • Dimensi: 60 mm x 110 mm x 110 mm (H x W x D)

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

330881-28-11-214-00-02 specifies a metric PROXPAC XL integrated transducer configured with a 3300 XL 8 mm proximity probe with multiple hazardous area approvals (Option 28), a 110 mm standoff adapter (Option 11), a 214 mm probe penetration length (Option 214), no conduit fittings (Option 00), and a 3/4-14 NPT mounting thread (Option 02).

The PROXPAC XL Proximity Transducer Assembly integrates a 3300 XL 8 mm proximity probe and a 1-meter Proximitor sensor into a single, self-contained, protective housing. This design eliminates the need for an extension cable between the probe and Proximitor, as well as a separate external Proximitor enclosure, allowing field wiring to connect directly from the monitor to the PROXPAC XL terminal blocks.

Unlike other configurations in the 330881 metric series which may use non-approved probes (Option 16) or contain no probe at all (Option 00 or 01), this variant comes standard with the multiple-approval certified 3300 XL 8 mm probe. While alternative designs may omit the standoff adapter (Option 00) or feature customized conduit fittings such as PG21 or M25 options, this assembly is configured with a 110 mm standoff length, standard 3/4-14 NPT thread, and blanking plugs to seal the housing when external fittings are not required. The housing cover of the PROXPAC XL is made of glass-reinforced polyphenylene sulfide (PPS) thermoplastic containing conductive fibers to strengthen the assembly and dissipate electrostatic charge, offering Type 4X and IP66 environmental protection.

Features

  • Option 28: Integrated 3300 XL 8 mm proximity probe with multiple international hazardous area certifications (ATEX, IECEx, and North American approvals).
  • Option 11: 110 mm standoff adapter provides precise offset positioning from the machine casing.
  • Option 214: 214 mm probe penetration length accommodates deep installation requirements in large-diameter shafts or thick casings.
  • Option 00: Fittings kit with no active conduit fittings, supplied with two washers and two blanking plugs to protect open ports.
  • Option 02: 3/4-14 NPT mounting thread ensures robust mechanical connection for the standoff adapter.
  • Glass-reinforced polyphenylene sulfide (PPS) thermoplastic housing containing conductive fibers to withstand mechanical impact and dissipate electrostatic charge.
  • Self-contained design combines both the probe and Proximitor sensor to eliminate extension cables and separate enclosures.
  • Type 4X and IP66 environmental ratings provide robust protection in harsh, wet, or corrosive environments.

Applications

  • Hydroelectric, steam, and gas turbine shaft vibration and position monitoring.
  • Industrial pumps, compressors, and fans in petrochemical and oil and gas installations.
  • Machinery protection systems requiring simplified wiring setups without auxiliary junction boxes.
  • Wet or corrosive industrial applications requiring Type 4X and IP66 environmental protection.

Ordering Information

Option Code on This SKU Description
Orderable Part Number 330881-28-11-214-00-02 Metric PROXPAC XL Proximity Transducer Assembly
A: Probe and Approvals Option 28 3300 XL 8 mm probe with Multiple Approvals
B: Standoff Adapter Option (B Dimension) 11 110 mm standoff adapter length
C: Probe Penetration Option (C Dimension) 214 214 mm probe penetration length
D: Fittings Option 00 No fittings; two plugs and two washers
E: Mounting Thread Option 02 3/4-14 NPT (Required if ordering Standoff Adapter Option)

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada (Baker Hughes)
Part Number 330881-28-11-214-00-02
Transducer Type Metric PROXPAC XL Integrated Proximity Transducer
Proximitor Input 3300 XL 8 mm Proximity Probe, 1-meter cable length
Input Voltage -17.5 Vdc to -26 Vdc (without barriers), -23 Vdc to -26 Vdc (with barriers)
Current Consumption 12 mA maximum
Output Resistance 50 ohms
Probe DC Resistance 7.59 +/- 0.50 ohms (center to outer conductor)
Field Wiring Compatibility 0.2 to 1.5 mm2 (16 to 24 AWG), 3-conductor shielded triax recommended
Maximum Field Wiring Distance 305 meters (1,000 feet) between Proximitor sensor and monitor
Linear Range 2.0 mm (80 mils), from approximately 0.25 mm (10 mils) to 2.3 mm (90 mils)
Recommended Gap Setting 1.27 mm (50 mils)
Incremental Scale Factor (ISF) 7.87 V/mm (200 mV/mil) +/- 5% (0 degC to +45 degC)
Deviation from Best Fit Straight Line (DSL) Less than +/-0.025 mm (+/-1 mil) at 0 degC to +45 degC
Frequency Response 0 to 10 kHz (+0, -3 dB) with up to 305 meters of field wiring
Minimum Shaft Diameter 50.8 mm (2.0 in)
Minimum Target Size 15.2 mm (0.6 in) diameter (flat target)
Housing Material Glass-reinforced polyphenylene sulfide (PPS) thermoplastic with conductive fibers (UV resistant)
Outer Sleeve Material AISI 304 stainless steel
Sleeve O-Ring Material Neoprene
Probe Tip Material Polyphenylene Sulfide (PPS)
Probe Case Material AISI 304 stainless steel
Probe Cable Type 75 ohm triaxial, FEP insulated, 1-meter length
Grounding Liner Material AISI 304 stainless steel
Isolation Material Extra Soft Cellular Silicone
Environmental Rating Type 4X and IP66
Operating Temperature (Probe) -52 degC to +177 degC (exposing below -34 degC may affect pressure seal)
Operating Temperature (Housing/Sensor) -52 degC to +100 degC
Storage Temperature -52 degC to +105 degC
Relative Humidity 100% condensing, non-submersible (when properly sealed)
Retaining Nut Torque 29.5 N-m (260 in-lb)
Probe Sleeve Locknut Torque 39.3 N-m (350 in-lb)

Installation Guidelines

  • Grounding: Ensure the internal grounding liner and retaining plate are properly connected to prevent ground loop interference.
  • Moisture Prevention: Use proper conduit seals and routing loops to prevent moisture from traveling through the conduit and accumulating in the PPS housing.
  • Probe Gap: Use the recommended gap setting of 1.27 mm (50 mils) corresponding to approximately -9 Vdc terminal output when configuring the system.
  • Standoff Stiffening: Assemblies with a combined standoff adapter and probe penetration length (B + C dimensions) exceeding 305 mm require additional sleeve support near the probe tip to prevent mechanical resonance.
  • Torque Limits: Tighten the probe sleeve locknut to 39.3 N-m (350 in-lb) and the outer housing retaining nut to 29.5 N-m (260 in-lb). Do not over-torque to prevent thread damage.

Compliance and Certifications

  • ATEX/IECEx: Ex ia IIC T5...T1 Ga, Ex ia IIIC T90C...T280C Dc (for hazardous dust atmospheres), Ex nA IIC T5...T1 Gc, Ex ec IIC T5...T1 Gc.
  • CSA/North America: Class I, Zone 0: AEx/Ex ia IIC T4/T5 Ga; Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III. Class I, Zone 2: AEx/Ex nA IIC T5...T1 Gc; Class I, Zone 2: AEx/Ex ec IIC T5...T1 Gc.
  • CE Mark: Complies with applicable European Union directives.
  • Ingress Protection: IP66 housing rating (verified by BASEEFA report T07/0709) and Type 4X environment rating.
Loading product navigation…

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Bently Nevada 330881-28-11-214-00-02 PROXPAC XL Proximity Transducer

What does the 28 option specify in the 330881-28-11-214-00-02 assembly?

The 28 option specifies a 3300 XL 8 mm proximity probe with Multiple Approvals, certified for international hazardous areas.

What are the installation lengths for this specific PROXPAC XL configuration?

This configuration features a 110 mm standoff adapter length (Option 11) and a 214 mm probe penetration length (Option 214) inside the metric sleeve.

Does the 330881-28-11-214-00-02 include cable fittings?

No, the Option 00 specifies that no cable fittings are included with this kit. It comes supplied with two washers and two blanking plugs to seal the housing holes.

What mounting thread is used for this transducer assembly?

This unit features a 3/4-14 NPT mounting thread (Option 02) to secure the standoff adapter.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan untuk Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...