Bently Nevada 9200-03-05-10-00 9200 Series Two-Wire Seismoprobe Velocity Transducer

Bently Nevada 9200-03-05-10-00 9200 Series Two-Wire Seismoprobe Velocity Transducer

Hanya 4 item tersisa di stok
  • Produsen: Bently Nevada

  • Nomor Produk: 9200-03-05-10-00

  • Negara asal:Amerika Serikat

  • Jenis Produk: Velocity Transducers

  • Pembayaran: T/T, Western Union

  • Berat: 320g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed for continuous machinery vibration monitoring, the Bently Nevada 9200-03-05-10-00 functions as a self-generating, two-wire velocity sensor that translates casing vibration into an electrical signal. This moving-coil transducer is engineered specifically for vertical installation configurations, operating at a 90-degree angle to provide high-precision measurements of absolute structural vibration on bearing housings, casings, or structural supports. By utilizing a passive design, this transducer operates without external power, converting physical motion directly into an AC voltage output proportional to vibration velocity.

Features

  • Self-Generating Operation: Moving-coil configuration requires zero external excitation voltage or auxiliary power.
  • Vertical Orientation Calibration: Factory-calibrated for 90 degrees (plus/minus 2.5 degrees) mounting angles.
  • Low-Frequency Capability: Minimum operating frequency rating of 4.5 Hz (270 cpm) for capturing low-speed machinery defects.
  • Terminal Block Interface: Top-mounted terminal block connection eliminates molded cable dependencies for field-terminated wiring.
  • Robust Mounting Interface: Features a circular base equipped with an M10x1 stud for high-frequency transmission.

Applications

  • Vertical industrial pumps and motor casing vibration monitoring
  • Large fans, blowers, and air-handling equipment maintenance paths
  • Hydroelectric generator bearing housing structural tracking
  • Casing vibration measurements on steam and gas turbines

Technical Specifications

Parameter Specification Value
Manufacturer Bently Nevada
Model Number 9200-03-05-10-00
Transducer Type Two-wire moving-coil velocity transducer
Mounting Angle Option 90 degrees plus/minus 2.5 degrees (Vertical)
Minimum Operating Frequency 4.5 Hz (270 cpm)
Connection Option Terminal block, top mount (no cable included)
Mounting Base Circular base with M10x1 threaded stud
Agency Approvals Option 00 (No hazardous area approvals)
Shipping Weight (Calculated) 2.0 kg

Connections and Interfaces

The top-mounted terminal block option simplifies on-site wiring without requiring proprietary molded connector cables. Ensure proper polarity connections to preserve signal phase relative to machinery vibration direction.

Terminal designation Signal Assignment
A (+) Signal Positive (High side of coil)
B (-) Signal Negative (Low side of coil / Common)
Shield / Case Ground Cable shield termination (to be isolated at the sensor case and grounded at the monitor end only)

Empirical Engineering Insights

Alternative Models & Compatibility

The 9200 series moving-coil Seismoprobe is a legacy mechanical design. It is highly valued because it does not require external power loops, unlike modern solid-state piezo-velocity sensors (such as the Bently Nevada 330500 Velomitor). If you are replacing a 9200 unit, you must match the mounting angle option exactly. A vertical "-03" model (90 degrees) cannot be replaced with a horizontal "-01" or "-02" model, as the internal spring suspension is physically tuned to counteract gravity only at the specified operating orientation.

Application Pitfalls & Engineering Notes

Cross-axis sensitivity is a known limitation of moving-coil transducers. To prevent physical wear on the internal coil guide and to avoid false signal generation, the sensor must not deviate more than plus/minus 2.5 degrees from the vertical axis. Additionally, check for nearby magnetic fields; because the 9200 uses an internal permanent magnet and moving coil, high-power magnetic fields from adjacent large motors can induce noise directly into the signal path.

Commissioning & Wiring Tips

When wiring to the terminal block, prevent dynamic stress on the terminals by installing a physical strain relief clamp within 100 mm of the sensor head. This prevents wiring fatigue from continuous structural vibration. Always use twisted, shielded cable (typically 18 AWG to 22 AWG) and ensure the shield is floated at the sensor and grounded at the rack monitor to mitigate ground loop noise.

Installation Guidelines

CRITICAL WARNING: Prior to installation or replacement, ensure that all machinery is safely locked out and de-energized. Do not mount the transducer on surfaces that exceed the maximum rated thermal capacity of the unit, as overheating can permanently demagnetize the internal moving-coil system, causing permanent sensitivity loss.
1

Prepare the mounting surface. It must be flat, smooth, and free of paint, rust, or debris. A surface finish of 1.6 micrometers (63 microinches) or better is recommended.

2

Apply an approved thread-locking compound to the M10x1 stud threads. Thread the sensor onto the mounting hole and torque to the manufacturer's specification using a flat wrench on the housing hex flats (do not hand-tighten by twisting the terminal head).

3

Confirm vertical alignment using a precision level or inclinometer. The deviation from vertical must be less than 2.5 degrees.

4

Connect the field wiring to the terminal block. Secure the cable with local flexible conduit or strain-relief clamps to prevent mechanical fatigue on the connections.

Loading product navigation…

Does the 9200-03-05-10-00 transducer require external power?

No. This is a moving-coil velocity transducer which is self-generating. It converts physical vibration directly into an AC electrical voltage without requiring external loop power.

Can I mount this transducer at a horizontal angle?

No. The 9200-03-05-10-00 features the -03 mounting angle option, which is calibrated specifically for vertical mounting (90 degrees plus/minus 2.5 degrees). Mounting it horizontally will cause the internal spring suspension to malfunction.

What cable is required for the terminal block connection?

Standard twisted, shielded pair cable (typically 18 to 22 AWG) is recommended. The terminal block does not require proprietary pre-molded connectors.

What is the physical mounting thread size for this model?

The mounting base option is a circular design with an M10x1 threaded mounting stud.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...