1 dari 3

Pengontrol Honeywell CC-PCNT02 51454551-275 Experion PKS C300

Pengontrol Honeywell CC-PCNT02 51454551-275 Experion PKS C300

Hanya 15 item tersisa di stok
  • Produsen: Honeywell

  • Nomor Produk: CC-PCNT02

  • Negara asal:Amerika Serikat

  • Jenis Produk: Modul Pengontrol C300

  • Pembayaran: T/T, Western Union

  • Berat: 1100g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Deskripsi

Honeywell CC-PCNT02 (nomor bagian 51454551-275) adalah node Pengontrol C300 yang beroperasi dalam arsitektur Experion PKS (Process Knowledge System). Perangkat ini menjalankan infrastruktur perangkat lunak Control Execution Environment (CEE) untuk memberikan kontrol proses, eksekusi regulasi, logika, operasi berurutan, dan kontrol berbasis model di seluruh jaringan proses industri.

Dirancang untuk aplikasi kontrol proses, pengontrol C300 ini memproses strategi kontrol dan mengelola komunikasi di jaringan kontrol pengawas Fault Tolerant Ethernet (FTE) serta tautan I/O lokal. Beroperasi pada platform IOTA, CC-PCNT02 mendukung firmware fungsi tambahan termasuk integrasi Ethernet Interface Module (EIM) dan Profit Controller, menggantikan model lama CC-PCNT01 dalam instalasi otomasi proses.

Fitur

  • Menjalankan Control Execution Environment (CEE) dengan periode eksekusi dasar 50 ms dan 20 ms.
  • Memiliki dua tautan I/O yang mendukung Series C I/O (750 Kbaud) dan tautan PMIO (375 Kbaud).
  • Dapat dikonfigurasi untuk pasangan pengontrol redundan deterministik menggunakan kabel Ethernet STP.
  • Terintegrasi langsung dengan jaringan kontrol FTE Level 1 melalui unit Control Firewall (CF9).
  • Mendukung protokol sinkronisasi waktu PTPv2 dan SNTP dengan periode pembaruan SNTP 1 menit.
  • Menyediakan 14.852 MU (Memory Units) total memori pengguna CEE yang tersedia.
  • Mampu menampung hingga 4095 blok bertanda per instance CEE.

Aplikasi

  • Otomasi proses dan kontrol pengawas pabrik
  • Kontrol regulasi dan logika berkelanjutan
  • Eksekusi proses berurutan dan batch otomatis
  • Aplikasi kontrol turbomachinery (mode eksekusi CEE 20 ms)
  • Integrasi DCS pihak ketiga melalui arsitektur PCDI Modbus TCP

Spesifikasi Teknis

Parameter Spesifikasi
Produsen Honeywell
Model CC-PCNT02
Nomor Bagian 51454551-275
Seri Pengontrol Experion PKS Pengontrol C300
Periode Eksekusi Dasar 50 ms CEE / 20 ms CEE
Total Memori Pengguna CEE Tersedia 14.852 MU (1 MU = 1024 byte)
Maksimum Blok Bertanda Per CEE 4095
Maksimum Blok Komponen per CM 100
Maksimum Blok Komponen per SCM/RCM/MR 400
Tautan I/O yang Didukung 2 Tautan
Kecepatan Tautan I/O 750 Kbaud (Series C I/O), 375 Kbaud (Tautan PMIO, hanya 50 ms CEE)
Antarmuka Jaringan Fault Tolerant Ethernet (FTE) melalui Control Firewall
Sinkronisasi Waktu SNTP (periode pembaruan 1 menit), PTPv2 (periode pembaruan 30 detik)
Maksimum Unit I/O (50 ms CEE) 64 (hingga 80 untuk PM IOPs atau Series C IOMs saja)
Maksimum Unit I/O (20 ms CEE) 12
Unit Koneksi Rekan (PCUs) 30 (50 ms CEE) / 53 (20 ms CEE)
Waktu Pergantian Interupsi Redundansi 500 ms (50 ms CEE) / 200 ms (20 ms CEE)
Ukuran IOTA 6 inci

Panduan Instalasi

  • Pasang modul pengontrol pada IOTA (Input Output Termination Assembly) 6 inci yang kompatibel.
  • Sambungkan setiap node pengontrol C300 langsung ke Control Firewall (CF9) khusus pada jaringan FTE.
  • Untuk konfigurasi redundan, pasang dua pengontrol pada IOTA terpisah menggunakan kabel redundansi Ethernet STP dengan panjang yang disetujui (36, 48, 60, atau 84 inci).
  • Konfigurasikan alamat indeks perangkat menggunakan indeks ganjil n untuk node utama dan n+1 untuk node mitra redundan.
  • Pastikan pengaturan jalur kabel dan pelindung yang tepat di seluruh koneksi Jaringan Kontrol FTE L1 untuk mengurangi gangguan elektromagnetik.

Product Documentation

Technical Datasheet (PDF) Complete specifications and technical drawings.

Technical Datasheet

Pengontrol Honeywell CC-PCNT02 51454551-275 Experion PKS C300

What is the primary difference between the 50 ms and 20 ms CEE execution modes on this controller?

The 50 ms CEE mode supports full DCS process control, PMIO, Series C I/O, and advanced applications like Profit Controller. The 20 ms CEE mode is optimized specifically for high-speed turbomachinery control applications with dedicated Series C I/O limits.

How is redundancy configured between two controller modules?

Redundancy requires two modules on separate IOTAs connected via Ethernet STP redundancy cables. The primary module is assigned an odd device index n, and the partner node is assigned index n+1.

Does this controller model replace older hardware versions in existing systems?

Yes, model CC-PCNT02 replaces model CC-PCNT01 for new installations and field replacements, providing support for extended functionality firmware images.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Color pattern
Putih Keabu-abuan Perak
Country of origin
Amerika Serikat
Power source
Daya DC

Produk yang Baru Dilihat

Pengetahuan teknis

Memodernisasi Bailey INFI 90 Symphony HMI yang Berjalan di OpenVMS Alpha

Panduan praktis untuk mengganti stasiun operator Bailey Symphony yang sudah tua dan berjalan di OpenVMS Alpha. Panduan ini membandingkan emulasi Alpha, migrasi OpenVMS x86, re-platforming OPC, dan...

Mengapa Data Pemeliharaan Penting untuk Keandalan Industri

Data pemeliharaan menghubungkan perintah kerja, sinyal sensor, riwayat aset, biaya, dan pengetahuan teknisi. Jika digunakan dengan baik, data ini meningkatkan perencanaan, keandalan, pemeliharaan...

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman PLC FBD: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...