1 dari 1

Honeywell CC-PWRR01 C300 Redundant Power Supply Module

Honeywell CC-PWRR01 C300 Redundant Power Supply Module

Hanya 7 item tersisa di stok
  • Produsen: Honeywell

  • Nomor Produk: CC-PWRR01

  • Negara asal:Amerika Serikat

  • Jenis Produk: PLC Power Supply Modules

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Dimensi: 250 x 180 x 120 mm (9.84 x 7.09 x 4.72 in)

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Delivering regulated, highly reliable power distribution within the Experion C300 controller subsystem, the Honeywell CC-PWRR01 functions as a dual-channel redundant power source designed to protect critical process control loops from input line failures. This module integrates directly into the Series C power carrier assemblies, allowing for seamless load-sharing, active diode auctioning, and uninterrupted power handovers. Engineered specifically to meet the high-availability demands of modern continuous process environments, the Honeywell CC-PWRR01 stabilizes system voltages, filters electromagnetic interference, and provides real-time diagnostic status feedback directly to the controller architecture.

Features

  • Active Redundant Load-Sharing: Seamlessly balances the current demand between paired power modules to extend component lifecycle and ensure zero-millisecond failover.
  • Hot-Swappable Architecture: Permits safe removal and replacement of a faulted power supply module while the process system remains fully energized.
  • Diagnostic Status Indication: Front-panel LEDs provide immediate, clear visual states of input power viability, output regulation, and over-temperature faults.
  • Integrated Diode Auctioning: Eliminates the risk of back-feeding or circuit disruption in the event of an internal component short-circuit.
  • Heavy-Duty Industrial Filtering: Built-in transient voltage surge suppression (TVSS) shields downstream C300 controllers and Series C I/O modules from grid irregularities.

Applications

  • Petrochemical refining and high-availability chemical synthesis plants.
  • Base-load and peak-generation thermal and combined-cycle power facilities.
  • Continuous process pulp, paper, and metallurgy control networks.
  • Offshore oil platform Emergency Shutdown (ESD) and Fire & Gas (F&G) systems.

Technical Specifications

Parameter Value / Specification
Manufacturer Honeywell
Model Number CC-PWRR01
System Compatibility Experion C300 / Series C I/O
Output Voltage 24 VDC nominal
Configuration Redundant (requires matching module on compatible carrier)
Cooling Method Natural convection
Operating Temperature 0 to 60 degC (32 to 140 degF)
Storage Temperature -40 to 85 degC (-40 to 185 degF)
Relative Humidity 5% to 95% non-condensing
Country of Origin United States / Global OEM sites
Shipping Weight (Calculated) 2.00 kg (4.41 lbs)
Package Dimensions (Calculated) 250 x 180 x 120 mm (9.84 x 7.09 x 4.72 in)

Connections and Interfaces

Connection Point Function / Circuit Assignment
Backplane Connector High-current blind-mate interface interfacing directly with the power carrier bus bars.
Status LED Array Visual indicators for Input OK (Green), Output OK (Green), and Module Fault/Over-Temp (Red).

Empirical Engineering Insights

Alternative Models & Compatibility

The CC-PWRR01 is designed specifically for insertion into the CC-PWRB01 (or equivalent) redundant power carrier. When performing system upgrades or migrations from legacy Experion platforms, verify that your existing carrier backplane is rated to accept Series C Form-Factor modules, as keying pins prevent physical mismating with non-compatible I/O racks.

Application Pitfalls & Engineering Notes

To guarantee optimal MTBF, maintain at least 50mm of clear space above and below the power carrier assembly to allow unobstructed convective airflow. In highly enclosed or non-ventilated field cabinets, thermal concentration can cause premature aging of the internal electrolytic capacitors. Always implement external ambient monitoring within the cabinet to ensure temperatures do not exceed the 60 degC threshold.

Commissioning & Wiring Tips

When bringing a redundant pair online, energize the primary and secondary power sources from isolated feed breakers. This layout ensures that an upstream breaker trip on Feed A does not compromise Feed B. Utilize the dry-contact alarm terminal block on the redundant carrier to route power fail status signals back to your diagnostic alarm logs in Experion PKS.

Installation Guidelines

CRITICAL WARNING: Ensure all incoming primary AC or DC power feeds are locked out, tagged out, and verified de-energized prior to installing, removing, or wiring any power carrier components. Working on live terminations poses severe flashover, shock, and equipment damage risks.
1
Mount the compatible Series C Redundant Power Carrier securely to the standard 35mm DIN rail or cabinet backplate using rugged grounding screws.
2
Align the CC-PWRR01 module with the dedicated slot guides on the carrier card. Slide the unit firmly until the blind-mate backplane connectors fully seat and the retaining mechanism clicks into place.
3
Connect your input feed wires to the respective terminal terminals on the carrier block, verifying torque settings match Honeywell installation specs. Do not over-tighten.
4
Apply power to Feed A and verify the corresponding LED lights up Green. Repeat for Feed B, ensuring both modules operate in active load-sharing configuration.
Loading product navigation…

Can I hot-swap the CC-PWRR01 module while the C300 controller is running?

Yes. This power supply supports full hot-swap capability when installed on a redundant carrier backplane. The sister module will immediately shoulder the entire current load without interruption.

What is the primary indicator of a complete unit failure on this module?

An internal fault or over-temperature condition is indicated by a solid red LED on the front panel, and the Output OK green LED will turn off.

Is external diode protection required for redundant configurations?

No. The module features integrated auctioning diodes designed to prevent back-feeding, making external diode modules unnecessary.

How should I handle thermal management when mounting multiple modules?

Ensure a minimum of 50mm spacing above and below the power carrier assembly to facilitate natural air convection and prevent heat buildup.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...