Lenze E82ZAFD 8200-series CANopen Function Module

Lenze E82ZAFD 8200-series CANopen Function Module

Hanya 7 item tersisa di stok
  • Produsen: Lenze

  • Nomor Produk: E82ZAFD

  • Negara asal:Jerman

  • Jenis Produk: Communication Modules

  • Kode batang: 85177100

  • Pembayaran: T/T, Western Union

  • Berat: 20g

  • Dimensi: 80 mm x 50 mm x 30 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Kuantitas
Lihat detail lengkap

Integrating seamlessly into the 8200 vector frequency inverter range, the Lenze E82ZAFD serves as a dedicated CANopen communication interface designed to facilitate high-speed, deterministic data exchange across industrial automation networks. This module mounts directly onto the front-facing Application Interface (AIF) slot of the drive, eliminating the need for external mounting hardware or additional control wiring.

Key Features

  • Direct integration into the Lenze 8200 vector drive AIF slot.
  • Full compliance with the CANopen communication protocol according to DS301 profile specifications.
  • Configurable baud rates up to 1 Mbps, adjustable via integrated DIP switches or internal drive parameter codes.
  • Electrical isolation between the CAN bus network medium and the internal drive control electronics to prevent ground loops.
  • Onboard diagnostic LEDs providing real-time visual feedback on network status and module power.

Applications

  • Decentralized drive control architectures in manufacturing and assembly lines.
  • Multi-axis synchronized motion control applications.
  • Conveyor systems, material handling, and packaging machinery.
  • Integration of legacy Lenze 8200 vector drives into modern CANopen master control systems.

Technical Specifications

Manufacturer Lenze
Model Number E82ZAFD
Series 8200-series
Module Type Function Module / Communication Interface
Communication Protocol CANopen (DS301)
Baud Rate Range 20 kbps to 1 Mbps
Node Address Range 1 to 63 (configurable via DIP switches or codes)
Interface Slot Type AIF (Application Interface)
Country of Origin Germany
Shipping Weight (Calculated) 0.02 kg
Package Dimensions (Calculated) 80 mm x 50 mm x 30 mm

Connections and Interfaces

Terminal / Pin Function / Circuit Assignment
CAN_H CAN High Signal Line
CAN_L CAN Low Signal Line
GND CAN Reference Ground (Isolated)

Alternative Models & Compatibility

The E82ZAFD is backwards compatible with all standard Lenze 8200 vector frequency inverters ranging from 0.25 kW to 90 kW. It directly replaces non-isolated CAN communication modules. Note that depending on the firmware revision of your 8200 vector drive (specifically revisions below V2.0), certain advanced CANopen monitoring objects may have limited access, requiring configuration via the standard drive keypad parameter codes.

Application Pitfalls & Engineering Notes

A common point of failure during commissioning is the omission of the physical 120-ohm termination resistor. The E82ZAFD does not feature an internal software-switchable termination resistor; therefore, a physical 120-ohm resistor must be wired externally across the CAN_H and CAN_L terminals at the first and last physical nodes of the bus. Operating without proper termination leads to intermittent frame errors, packet loss, and drive communication faults (typically triggering a CE0 or CE3 fault on the inverter).

Commissioning & Wiring Tips

To ensure robust noise immunity in high-EMI environments, use only high-quality shielded twisted-pair (STP) cabling specified for CAN networks. Route the communication cable at least 20 cm away from high-voltage motor output cables and AC supply lines. The cable shield must be grounded at a single point (typically at the master controller) to prevent ground loops from corrupting the differential communication signals.

Installation Guidelines

CRITICAL WARNING

Before installing or removing the E82ZAFD module, completely de-energize the main AC supply to the Lenze 8200 vector inverter. Wait at least 5 minutes for the internal DC-bus capacitors to fully discharge to safe voltage levels. Verify zero voltage at the power terminals before proceeding. Hot-plugging the module will cause permanent damage to the AIF interface and the drive's control board.

1

Ensure the inverter is completely powered down and the DC-bus discharge time has elapsed.

2

Set the required node address and baud rate using the DIP switches located on the side of the E82ZAFD module before inserting it into the slot.

3

Align the module carefully with the AIF slot on the front of the 8200 vector inverter and press firmly until the retaining clips click into place.

4

Connect the CAN bus lines (CAN_H, CAN_L, and GND) to the pluggable terminal block, ensuring correct polarity and shielding termination.

Loading product navigation…

Which inverters are compatible with the E82ZAFD module?

The E82ZAFD is designed specifically for the Lenze 8200 vector frequency inverter series, plugging directly into the front-mounted AIF slot.

How do I set the node address and baud rate on this module?

Node addresses and transmission speeds can be configured either physically via the integrated DIP switches on the module or programmatically using Lenze drive codes.

What does a flashing red LED on the E82ZAFD indicate?

A flashing red LED typically indicates a CANopen communication error, such as a bus-off state, configuration mismatch, or missing network termination.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 2:00 PM (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian kembali, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jerman

Produk yang Baru Dilihat

Pengetahuan teknis

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Dari sistem perekat yang terinspirasi oleh tokek dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga AI,...

Throwback: Bagaimana Motor Listrik Awal Mengubah Pertambangan Bawah Tanah

Dari kompresor DC yang digerakkan tali hingga gerobak tambang bertenaga baterai, operasi pertambangan awal menandai titik balik dalam elektrifikasi industri. Artikel ini mengeksplorasi bagaimana...

Factory I/O: Alat Simulasi PLC Modern untuk Pelatihan Otomasi Industri

Factory I/O mengubah pendidikan PLC dengan menyediakan simulasi industri 3D yang imersif untuk siswa, insinyur, dan tim pemeliharaan. Platform ini menjembatani kesenjangan antara teori dan praktik...

Pemrograman Siklus Gerakan Sumbu Tunggal pada CMZ Servo Drive

Tutorial ini membahas bagaimana fungsi PLC onboard di dalam drive servo CMZ SBD dapat menjalankan program gerakan mandiri, termasuk logika homing, kontrol posisi, dan pergerakan sumbu siklik tanpa...