1 dari 1

Mitsubishi Electric FR-A740-15K FR-A700 Variable Frequency Drive

Mitsubishi Electric FR-A740-15K FR-A700 Variable Frequency Drive

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: FR-A740-15K

  • Negara asal:Amerika Serikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 7500g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Providing high-performance vector control for heavy-duty industrial applications, the Mitsubishi Electric FR-A740-15K frequency inverter delivers precise motor regulation across demanding operational profiles. This variable frequency drive (VFD) from the FR-A700 Series is engineered for complex systems requiring high torque, exceptional speed accuracy, and advanced motor control dynamics. Operating on a 400V class three-phase input, it handles a nominal motor output of 15 kW, making it a reliable component in heavy machinery, extrusion lines, cranes, and continuous manufacturing systems.

Equipped with Real Sensorless Vector (RSV) control and advanced vector control algorithms, the drive achieves outstanding speed and torque performance without requiring encoder feedback. The integrated PLC functionality allows users to customize control sequences directly within the inverter, reducing external hardware overhead and simplifying system integration.

Features

  • Real Sensorless Vector Control: Achieves high torque at ultra-low speeds (200% at 0.3 Hz) for high-inertia start-up profiles.
  • Optimum Excitation Control: Automatically adjusts the excitation current to maximize motor efficiency, reducing energy consumption under partial loads.
  • Built-in PLC Programming: Enables customized logic and automated control loops via Mitsubishi's software environment, bypassing the need for an external micro-PLC.
  • Advanced Torque Limiters: Protects mechanical drivetrains with fast, highly responsive 4-quadrant torque limitation.
  • USB Port Integration: Front-mounted interface for swift configuration, diagnostics, and parameter backup using FR Configurator software.

Applications

  • Hoists and Cranes: High-starting torque and mechanical brake control linkage ensure safe and smooth vertical transitions.
  • Extruders and Mixers: Provides stable speed regulation under fluctuating viscosity loads.
  • Centrifuges and Fans: Energy-efficient operation through optimized excitation and smooth deceleration control.
  • Conveyor Networks: Precise multi-drive speed synchronization prevents physical product damage and belt wear.

Technical Specifications

Parameter Value / Specification
Manufacturer Mitsubishi Electric
Model Number FR-A740-15K
Inverter Series FR-A700
Voltage Class 400V Class (Three-Phase 380 to 480 VAC, 50/60 Hz)
Permissible AC Voltage Fluctuation 323 to 528 VAC (50Hz/60Hz)
Applicable Motor Capacity 15 kW
Rated Output Current 31 A
Overload Current Rating 150% 60 seconds, 200% 3 seconds (at ambient temperature of 50 degC)
Cooling Method Forced Air Cooling
Enclosure Rating IP20 (Open Type)
Net Weight 7.5 kg
Shipping Weight (Calculated) 9.0 kg

Connections and Interfaces

Terminal Group Functional Assignment
R/L1, S/L2, T/L3 Main 3-phase AC power supply input terminals.
U, V, W 3-phase AC output connections to the induction motor.
P/+, PR Connection terminal for optional external brake resistor.
STF / STR Forward rotation start / Reverse rotation start control terminals.
10, 2, 5 Analog input terminals (0 to 10 VDC, 4 to 20 mA) for external frequency references.

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating or sourcing drop-in replacements, note that the FR-A740-15K shares functional equivalents within the newer FR-A840-00380-E2-60 (A800 series). Parameter transfer from the A700 to the A800 series can be automated via the FR Configurator2 software. However, verify terminal assignment modifications, as the control terminal blocks differ in wiring entry formats (screw terminals on the A700 vs. spring clamp terminals on the A800).

Application Pitfalls & Engineering Notes

If operating in high ambient conditions (above 40 degC), the carrier frequency should be adjusted downward (Parameter 72) to prevent premature thermal overcurrent faults (E.THT). Avoid continuous operation below 6 Hz without supplementary external motor cooling fan kits, as standard self-cooled motors will experience severe thermal degradation at reduced speeds due to diminished internal fan velocity.

Commissioning & Wiring Tips

Always ensure that Parameter 9 (Electronic Thermal O/L Relay) is set to match the nameplate current of the connected motor; the factory default corresponds to the maximum rating of the VFD and may fail to protect smaller motors. Install control signals using shielded twisted-pair cables with the shield grounded only at the drive end (Terminal 5) to mitigate electromagnetic interference in analog circuits.

Installation Guidelines

CRITICAL WARNING: HIGH VOLTAGE HAZARD

Isolate all input AC power before performing any terminal modifications or inspection routines. Wait a minimum of 10 minutes after physical power disconnection for the internal DC-bus capacitors to fully discharge. Verify that the DC-bus voltage between terminals P/+ and N/- is below 45 VDC using a calibrated digital multimeter before proceeding with touch operations.

1

Mount the inverter vertically inside an IP54 enclosure if the environment is dusty or humid, ensuring a minimum clearance of 10 cm above and below the unit for unobstructed heat dissipation.

2

Ensure the physical ground connection meets standard industrial safety requirements (Earth resistance under 10 ohms). Use a thick copper protective conductor connected to the drive's PE terminal.

3

Confirm that power cable routing is physically separated from control and encoder feedback signaling paths to minimize capacitive coupling noise.

Loading product navigation…

Can I run a standard induction motor at high torque at low speeds using the FR-A740-15K?

Yes. When set to Real Sensorless Vector (RSV) control, this VFD can deliver up to 200% starting torque at 0.3 Hz. Ensure that you run the offline auto-tuning function with the motor uncoupled to map the motor winding characteristics accurately.

What is the proper procedure if the E.THT fault occurs frequently?

The E.THT fault indicates motor thermal overload. Verify that Parameter 9 matches your motor's rated current. If the load requires low-speed operation under heavy load, consider installing an external forced cooling fan on the motor or lower the carrier frequency (Parameter 72) on the drive.

Does this drive require an external braking resistor for high-inertia stops?

Yes, for applications with rapid deceleration cycles or highly regenerative loads (such as cranes or high-inertia fans), you must connect an external brake resistor across terminals P/+ and PR. Ensure the braking duty cycle parameters are updated in the drive config.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...