1 dari 1

Mitsubishi Electric FR-A840-1.5K-1 FR-A800 Series Variable Frequency Drive

Mitsubishi Electric FR-A840-1.5K-1 FR-A800 Series Variable Frequency Drive

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: FR-A840-1.5K-1

  • Negara asal:Amerika Serikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 4500g

  • Dimensi: 260 mm x 150 mm x 140 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed for high-performance industrial motor control, the FR-A840-1.5K-1 by Mitsubishi Electric operates as a premium variable frequency drive within the FR-A800 series. This high-capacity inverter delivers exceptional speed and torque control for 1.5 kW three-phase motors, relying on advanced real-time sensorless vector control algorithms. Built to withstand demanding manufacturing environments, the unit integrates standard serial communication architectures, high-efficiency cooling, and robust overcurrent protection to ensure continuous field operation and minimize plant downtime.

Features

  • Real-time sensorless vector control capabilities for ultra-precise speed and torque response.
  • Built-in RS-485, RS-422, and RS-232 serial communication interfaces supporting Modbus RTU protocols.
  • Dual overload rating tolerance designed for versatile normal duty (ND) and light duty (LD) load characteristics.
  • Embedded safety-related stop function conforming to international industrial standards.
  • Integrated EMC filter to minimize electromagnetic noise and safeguard adjacent control instrumentation.

Applications

  • Material handling conveyor lines requiring precise acceleration and deceleration profiles.
  • Centrifugal pump systems and industrial fan setups utilizing variable torque optimization.
  • Extrusion lines and continuous mixers within chemical and plastics processing facilities.
  • Machine tool spindles requiring stable speed holding under variable mechanical loads.

Technical Specifications

Parameter Value
Manufacturer Mitsubishi Electric
Model Reference FR-A840-1.5K-1
Series Name FR-A800
Input Voltage Class Three-phase 400 V (380 to 500 VAC, 50/60 Hz)
Applicable Motor Capacity 1.5 kW
Output Rated Current 4.0 A
Output Rated Capacity 3.0 kVA
Communication Interfaces RS-232, RS-422, RS-485 (Mitsubishi / Modbus RTU)
Standards & Approvals CE, UL, cUL, RoHS
Enclosure Rating IP20
Physical Dimensions (H x W x D) 260 mm x 150 mm x 140 mm
Shipping Weight (Calculated) 4.5 kg

Connections and Interfaces

Terminal Designation Circuit / Function Assignment
R/L1, S/L2, T/L3 Main Three-Phase AC Power Input Connection
U, V, W Three-Phase Variable Frequency Output to Motor
P/+, PR Braking Resistor Connection Terminals
STF / STR Forward Run Start / Reverse Run Start Digital Inputs
SD Common Terminal for Digital Inputs and 24 VDC Power source
2, 4, 5 Analog Frequency Setting Inputs (Voltage / Current) & Common Ground

Alternative Models & Compatibility

The FR-A840-1.5K-1 serves as the direct technological replacement for legacy FR-A740-1.5K series drive models. While the footprint and control terminals line up similarly, please note that parameter structures have expanded. When utilizing FR Configurator2 software to import existing parameter files from A700 series models, a careful verification of acceleration-deceleration curve parameters and motor tuning maps must be performed to ensure smooth commissioning.

Application Pitfalls & Engineering Notes

During integration inside IP54 enclosed control panels, local heat dissipation must be handled correctly. The drive requires a minimum space clear-zone of 50 mm above and below the chassis for unimpeded natural airflow. In applications operating continuously at low speeds under high-torque demand, the integrated motor fan will lose efficiency. Always implement an external forced cooling fan on the motor or utilize inverter-duty rated motors to prevent winding thermal trips (E.THT faults).

Commissioning & Wiring Tips

Ensure that Parameter 79 (Operation Mode Selection) is explicitly set to match your system master. For example, setting Pr.79 to "2" locks control logic exclusively to the external terminals, bypassing the PU keypad. For RS-485 serial communication daisy chains, apply a terminating resistor on the final physical node and run standard double-shielded twisted pair (STP) control cables. The shield must be terminated strictly at a single point (PE ground at the cabinet entry) to prevent destructive ground loops.

Installation Guidelines

CRITICAL WARNING

Isolate all main power lines prior to physical cabinet mounting or control terminal wiring. Once input power is switched off, wait a minimum of 10 minutes for the internal DC bus capacitors to fully discharge. Always measure the DC bus voltage across terminals P/+ and N/- using a calibrated digital multimeter to verify the potential is below 50 VDC before initiating touch-sensitive electrical tasks.

1

Securely mount the variable speed drive on a rigid, vibration-resistant vertical panel backplate using appropriate M5 bolts.

2

Connect the physical PE protective ground terminal directly to the central cabinet earth bar before wiring power supply lines.

3

Terminate the three-phase power lines at R/L1, S/L2, and T/L3, ensuring correct phase configuration, and route the motor outputs from U, V, and W.

4

Secure control signal wiring away from the high-voltage power lines inside separate wire ducting lanes to prevent inductive cross-talk.

Loading product navigation…

What is the rated output current of the FR-A840-1.5K-1 under normal duty conditions?

The rated output current for this model is 4.0 A under Normal Duty (ND) conditions, specifically configured to drive a 1.5 kW induction motor.

Can I run this variable speed drive with a single-phase supply?

No. The drive is designed strictly for three-phase AC power input ranging from 380 to 500 VAC. Attempting to power it on a single-phase line will cause input phase failure trips.

Which communication interfaces are natively integrated into the FR-A840-1.5K-1?

The drive features integrated RS-485, RS-422, and RS-232 serial interfaces, allowing communication using Mitsubishi Electric RTU protocols or standard Modbus RTU.

What is the recommended environmental temperature limit for operating this VFD?

The drive operates reliably at ambient temperatures between -10 degC and +50 degC under non-freezing conditions. Derating is required for ambient temperatures above 50 degC.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat