1 dari 1

Mitsubishi Electric FR-E840-0230-4-60 FR-E800 Variable Frequency Drive

Mitsubishi Electric FR-E840-0230-4-60 FR-E800 Variable Frequency Drive

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: FR-E840-0230-4-60

  • Negara asal:Amerika Serikat

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 4800g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed to deliver precise speed and torque control for three-phase induction and permanent magnet motors, the Mitsubishi Electric FR-E840-0230-4-60 is a high-performance 400V class variable frequency drive from the FR-E800 series. Featuring a conformal circuit board coating (designated by the -60 suffix), this unit is engineered for enhanced environmental resilience in atmospheres containing conductive dust, moisture, or corrosive gases. It operates with a Normal Duty (ND) rated current of 23.0 A and implements standard source logic (PNP) for its control and safety stop input circuits. The integrated voltage monitoring capability via terminal AM provides real-time operational feedback to supervisory control systems.

Key Features

  • Environmental Protection: Features a robust conformal coating on the internal circuit boards to prevent degradation from atmospheric contaminants.
  • Source Logic Interface: Configured for PNP (source) control input and safety stop signals, facilitating seamless integration with standard safety relays and controllers.
  • Voltage Monitoring: Equipped with an analog voltage output via terminal AM for simple, direct scaling of operational parameters.
  • Flexible Control Options: Supports advanced vector control and auto-tuning protocols for high torque performance at low speeds.

Applications

  • Conveyor and Material Handling Systems: Precise speed synchronization and acceleration profiling.
  • Pumping and Fan Infrastructure: Energy-efficient flow control with built-in PID functionalities.
  • Packaging and Food Processing Machinery: Reliable operation in washdown-adjacent panels thanks to coated PCBs.
  • Compressors and Centrifuges: High-starting torque execution for high-inertia physical loads.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Mitsubishi Electric
Model Code FR-E840-0230-4-60
Series FR-E800
Voltage Class 400 V Class (Three-Phase Input)
Inverter ND Rated Current 23.0 A
Rated Frequency 50 Hz (Initial Setting)
Control Logic (Inputs) Source Logic (PNP)
Safety Stop Signal Logic Source Logic (Fixed)
Circuit Board Coating With Conformal Coating (Standard -60)
Plated Conductor Without Plated Conductors
Monitoring Specification Voltage (Terminal AM)
Device Net Weight 4.8 kg
Shipping Weight (Calculated) 7.0 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The "-60" suffix indicates that this drive is equipped with conformal PCB coating, making it physically interchangeable with standard uncoated FR-E840 models but highly preferred in corrosive or humid environments. Ensure that parameter configurations are cloned using FR Configurator2 software when swapping older FR-E700 series units, keeping in mind the structural differences in wiring terminals.

Application Pitfalls & Engineering Notes

When deploying this drive in dense control enclosures, keep the ambient air temperature under 50 degC. Surpassing this threshold requires appropriate current derating. If the drive is mounted side-by-side with zero clearance, the maximum operating temperature must be derated to 40 degC to avoid thermal overload faults.

Commissioning & Wiring Tips

This model is hard-configured for Source Logic (PNP) operation. When integrating with external controllers, ensure the common terminal connection matches the PNP routing path (typically terminal PC as 24VDC source). Use shielded twisted-pair cables for the AM voltage analog monitoring line to prevent inductive electrical noise from corrupting high-impedance feedback signals.

Installation Guidelines

CRITICAL WARNING: Hazardous voltage levels remain present in the internal DC bus capacitors even after mains power is disconnected. Disconnect all primary power feeds and verify that the charge LED on the front face of the drive has fully extinguished. Wait a minimum of 10 minutes before touching terminals or physical connections to prevent severe electrical shock.
1
Mount the inverter vertically on a flat, non-flammable backplate, ensuring at least 50mm of clearance at the top and bottom to allow adequate cooling air circulation.
2
Connect the incoming 400V three-phase utility power lines exclusively to terminals L1, L2, and L3. Connection of main power lines to output terminals U, V, or W will destroy the drive.
3
Establish a solid low-impedance ground connection from the drive chassis to the main electrical system protective earth (PE) bus.
4
Ensure control wires are routed away from power cabling to eliminate electromagnetic cross-talk and maintain signal integrity.
Loading product navigation…

What does the -60 suffix in the FR-E840-0230-4-60 part number indicate?

The -60 suffix specifies that the printed circuit board has a conformal coating. This provides essential moisture, chemical, and dust protection for reliable operation in harsh industrial environments.

Can I configure this drive for Sink (NPN) control logic?

No, this specific model (FR-E840-0230-4-60) is hard-configured with Source (PNP) logic for its safety stop inputs and standard digital control terminals.

What is the rated current of this FR-E800 inverter under Normal Duty (ND)?

The unit features a Normal Duty rated output current of 23.0 A, indicated by the '0230' sequence in the model code.

What type of analog monitoring signal is provided by terminal AM?

Terminal AM is configured for analog voltage output monitoring, typically used for scaling speed, current, or voltage feedback to an external controller or meter.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...