1 dari 1

Mitsubishi Electric FR-F840-00170-2-60 FR-F800 Series Inverter Drive

Mitsubishi Electric FR-F840-00170-2-60 FR-F800 Series Inverter Drive

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: FR-F840-00170-2-60

  • Negara asal:Amerika Serikat

  • Jenis Produk: Inverter Drives

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Regulating system dynamics with exceptional efficiency, the Mitsubishi Electric FR-F840-00170-2-60 is a dedicated variable frequency drive engineered primarily for pump, fan, and compressor operations. This FR-F800 Series controller provides precise speed regulation over three-phase AC motors, featuring dual overload ratings to optimize physical sizing and thermal margins. By utilizing advanced energy-saving algorithms, the drive dynamically adjusts excitation current in response to load fluctuations, maximizing operational efficiency under real-time conditions. The robust IP20 enclosure is designed for standardized panel mounting within industrial environments, incorporating integrated PID control loops to streamline system architectures without requiring external controllers.

Features

  • Dual Rating Modes: Features Super Light Duty (SLD) and Light Duty (LD) ratings to align precisely with specific torque applications.
  • Optimum Excitation Control: Automatically calculates and applies the ideal magnetic flux matching the load, minimizing thermal losses.
  • Built-In PID Controller: Allows direct process loop management for flow, pressure, or temperature regulation without PLC intervention.
  • Enhanced Safety Integration: Equipped with safety stop functions complying with global machinery protection requirements.
  • Integrated USB Port: Facilitates direct connection to engineering software for diagnostic plotting and parameter backups.

Applications

  • Fluid Management: Municipal and industrial water pump control, including booster systems and dry-run protection.
  • HVAC Systems: Intake, exhaust, and recirculation air-handling fans in commercial or industrial facilities.
  • Compressor Control: Dynamic speed control for positive-displacement and centrifugal air compression units.

Technical Specifications Table

Parameter Specification value
Manufacturer Mitsubishi Electric
Model Code FR-F840-00170-2-60
Series FR-F800
Power Rating 7.5 kW
Supply Voltage 380 to 500 V AC (3-Phase)
Rated Current (SLD) 17.0 A
Rated Current (LD) 16.0 A
Operating Temperature (SLD) -10 to +40 degC
Operating Temperature (LD) -10 to +50 degC
Ingress Protection Rating IP20
Shipping Weight (Calculated) 7.5 kg

Connections and Interfaces

Terminal Group Function / Circuit Assignment
R/L1, S/L2, T/L3 Three-phase AC main power supply inputs.
U, V, W Three-phase AC variable frequency outputs to motor.
STF / STR Forward rotation start / Reverse rotation start control lines.
10, 2, 5 Analog input terminals for external speed setting (0 to 10 V DC).
SD, SE Common terminals for digital inputs and open collector outputs.

Empirical Engineering Insights

Alternative Models & Compatibility

This unit directly succeeds legacy FR-F740 models. When transitioning, verify the operational parameter logic because terminal assignments match, but software parameters (especially those referencing motor constants and auto-tuning) require translation using FR Configurator2. Parameter conversion utilities within the software automate this migration but necessitate validation prior to line commissioning.

Application Pitfalls & Engineering Notes

When sizing for high-altitude operations, derate current output by 1% for every 100 meters above 1000 meters up to a maximum of 2500 meters. For applications involving high-inertia loads like large extraction fans, integrate an external braking resistor to prevent overvoltage trips (E.OV3) during deceleration phases, especially when rapid deceleration cycles are scheduled.

Commissioning & Wiring Tips

Ensure the control signal wiring is completely segregated from the primary motor and input power cables. Use shielded twisted-pair (STP) wiring for analog speed references (terminals 2 and 5) and tie the shield exclusively to terminal 5 on the drive side to eliminate ground loops. In noisy electromagnetic environments, installing a zero-phase reactor on the input line significantly mitigates EMI issues.

Installation Guidelines

CRITICAL WARNING: Hazardous voltages remain present on the internal DC bus capacitors even after the AC line power has been isolated. Wait a minimum of 10 minutes after disconnecting input power, and verify with a multimeter that the DC bus voltage across terminals P/+ and N/- is below 45 V DC before performing any electrical connection or inspection work.
1
Mount the inverter vertically on a flat, non-flammable surface inside an enclosure that maintains ambient temperatures within the operational thresholds (-10 to +50 degC for Light Duty setups).
2
Ensure minimum clearances of 50 mm above and below the drive and 20 mm on the sides to facilitate unhindered convection cooling.
3
Connect the protective earth (PE) terminal first, utilizing a low-impedance grounding cable to mitigate common-mode noise issues.
Loading product navigation…

What is the difference between the SLD and LD ratings on this inverter?

The Super Light Duty (SLD) rating is optimized for variable torque loads like fans and centrifugal pumps, allowing up to 17.0 A continuous current at ambient temperatures up to 40 degC. The Light Duty (LD) rating limits output to 16.0 A but permits operation at up to 50 degC for applications with slightly higher dynamic loading.

How do I clear an E.OV3 fault during motor deceleration?

An E.OV3 fault indicates regenerative overvoltage on the DC bus. You must increase the deceleration time parameter (Pr. 8), enable the deceleration stall prevention parameter, or install an external braking unit with a power resistor to dissipate the regenerated energy.

Can this drive run on a single-phase AC input supply?

No. The drive is specifically designed for a three-phase AC input supply ranging from 380 V to 500 V. Operating the unit on a single-phase supply will cause phase loss detection faults or degrade internal components due to input current overload.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...