Configured to deliver fast execution and dense local physical points, the Mitsubishi Electric FX2N-80MT-ES/UL serves as a high-density processing core within the FX2N micro PLC family. This unit integrates internal memory capacity, specialized high-speed counters, and dual-axis positioning outputs into a compact footprint. Designed for high-duty cycle industrial environments, it features a robust internal power supply and sink-logic transistor outputs suitable for driving interface relays, solenoids, and stepper/servo motor drives.

Product Features

  • High-Density I/O Layout: Equipped with 40 digital inputs (24 VDC, Sink logic) and 40 digital outputs (Transistor, Sink logic) in a single modular base unit.
  • Fast Logic Execution: Processes basic sequence instructions at 0.08 microseconds, ensuring precise real-time responsiveness for highly dynamic machine processes.
  • Expandable Program Capacity: Features a standard 8000-step RAM memory (battery-backed) that can be expanded to 16000 steps using optional EEPROM or EPROM cassettes.
  • Integrated Motion Controls: Provides two independent 20 kHz pulse train outputs (PLSY/PLSR instructions) for basic dual-axis positioning applications.
  • Flexible Signal Terminations: Outfitted with removable M3 screw terminal blocks to allow rapid field pre-wiring and minimize downtime during maintenance cycles.

Applications

  • Packaging and Labeling Machinery: Synchronizes continuous feed-rolls and quick-action cutting mechanisms using built-in high-speed counters.
  • Multi-Axis Material Handling: Manages local conveyor routing, sorting systems, and small-scale gantry positioning coordinates.
  • Automated Assembly Stations: Controls pneumatic actuators, monitors safety limit switches, and interfaces with indexing rotary tables.
  • Specialized OEM Equipment: Operates as a standalone machine controller in commercial food processing, textile machines, and custom tooling units.

Technical Specifications

Parameter Specification
Manufacturer Mitsubishi Electric
Model Number FX2N-80MT-ES/UL
Primary Input Power 100 to 240 VAC, 50/60 Hz (Allowable: 85 to 264 VAC)
Power Consumption 45 W
Service Power Output 24 VDC, 460 mA or less
Internal Supply 5 VDC, 290 mA
Execution Speed 0.08 microseconds / basic instruction
Digital Inputs 40 points (24 VDC, Sink/NPN format)
Input Impedance 3.3 kilohms (X000 to X007), 4.3 kilohms (X010 and higher)
Digital Outputs 40 points (Transistor, Sink/NPN format)
External Output Voltage 5 to 30 VDC
Maximum Output Current 0.5 A per point (0.8 A per 4-point common, 1.6 A per 8-point common)
High-Speed Counters 1-phase: up to 60 kHz; 2-phase: up to 30 kHz (configured via programming)
Pulse Output Frequency Max 20 kHz (Independent dual-axis control)
I/O Termination Removable M3 screw terminal blocks
Operating Temperature 0 to 55 degC
Shipping Weight (Calculated) 1.20 kg (2.65 lbs)
Package Dimensions (Calculated) 285 mm x 90 mm x 87 mm
Country of Origin Japan

Connections and Interfaces

Terminal / Port Function / Circuit Assignment
L, N, Ground AC Power input terminals (100 to 240 VAC, 50/60 Hz power source)
24V, 0V Auxiliary 24 VDC service power output (maximum 460 mA for field sensors)
X000 to X047 Sink configuration digital input terminals (X000 to X007 mapped for high-speed interrupts)
Y000 to Y047 Sink configuration (NPN) transistor output terminals (Y000 & Y001 dedicated to pulse outputs)
COM (Outputs) Common return terminals for transistor outputs (grouped in 1, 4, or 8 point configurations)
Peripheral Port RS-422 interface (8-pin mini-DIN) for HMI connection or GX Developer programming tools

Empirical Engineering Insights

Alternative Models & Compatibility

When replacing legacy FX series systems, note that the FX2N-80MT-ES/UL is specifically configured for NPN/Sink inputs and NPN/Sink transistor outputs. For installations demanding source (PNP) logic output control, the alternative model FX2N-80MT-ESS/UL should be sourced to prevent mismatched polarity on field relay manifolds or servo inputs.

Application Pitfalls & Engineering Notes

Ensure that the total power drawn from the 24 VDC auxiliary service terminals does not exceed 460 mA. Overloading this channel will cause the internal power supply to enter over-current protection mode, causing intermittent system shutdowns. For extensive sensor networks, always route field sensor power through an independent, external 24 VDC industrial power supply with a common ground reference to the controller's 0V terminal.

Commissioning & Wiring Tips

When utilizing high-speed counters (up to 60 kHz) on inputs X000 through X007, route high-speed encoder signaling wires inside dedicated, shielded twisted-pair cables. Ground the shield at the PLC-side chassis terminal only. Avoid laying encoder cables parallel to high-current power lines or AC motor drive leads within the wire duct to prevent high-frequency noise from corrupting pulse counts.

Installation Guidelines

CRITICAL WARNING

Isolate and lock out all AC mains power (100-240 VAC) feeding the controller before mounting or starting any wiring terminations. Work with insulated hand tools only. Verify that all terminal block retaining screws are securely tightened to prevent loose connections from causing thermal faults or arc damage.

1
Chassis Mounting: Install the main unit vertically onto a standard 35 mm DIN rail or bolt it securely using the integrated mounting brackets inside a well-ventilated, IP54-rated metal enclosure.
2
Ground Connection: Establish a dedicated low-resistance system ground path using a minimum of 2.0 mm² (14 AWG) wire connected directly to the protective earth terminal.
3
Input and Output Wiring: Strip the wire leads to a length of 6 mm, apply crimped bootlace ferrules, and insert them into the removable screw terminal blocks. Tighten the M3 terminal screws to a torque range of 0.5 to 0.8 N-m.
4
Pre-Power Inspection: Double-check all power supply connections on L and N before flipping the breaker. Power up the unit and verify that the "POWER" LED status light on the front panel remains solid green.
Loading product navigation…

What is the key electrical difference between the FX2N-80MT-ES/UL and the ESS/UL model?

The ES/UL model features NPN (sink) transistor outputs, whereas the ESS/UL variant utilizes PNP (source) transistor outputs. Field wiring must be designed according to this polarity.

What is the maximum output current capacity for the transistor outputs?

The outputs are rated for 0.5 A maximum per point. However, the common terminals have aggregate limits: 0.8 A for 4-point common groups and 1.6 A for 8-point common groups.

How much auxiliary current can the 24 VDC service power supply provide?

The internal service power supply provides up to 460 mA of auxiliary 24 VDC power, which can be used to power connected sensors or input switches.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...