1 dari 1

Mitsubishi Electric Q26UDEHCPU MELSEC Q Series Universal CPU Module

Mitsubishi Electric Q26UDEHCPU MELSEC Q Series Universal CPU Module

Hanya 10 item tersisa di stok
  • Produsen: Mitsubishi Electric

  • Nomor Produk: Q26UDEHCPU

  • Negara asal:Amerika Serikat

  • Jenis Produk: PLC CPU Modules

  • Pembayaran: T/T, Western Union

  • Berat: 1200g

  • Dimensi: 98 mm x 27.4 mm x 115 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Engineered for high-density, multi-disciplinary industrial control applications, the Mitsubishi Electric Q26UDEHCPU is an industrial-grade central processing unit designed for the MELSEC Q Series automation platform. This module integrates a built-in Ethernet port, enabling high-speed data transmission and seamless communication across factory networks. Featuring a highly optimized execution engine, it handles complex arithmetic, sequence controls, and structured text configurations with exceptional speed. Its physical design fits directly onto standard Q Series base units, making it ideal for systems requiring intensive calculations, multi-CPU coordination, and deep memory capacities.

Key Features

  • High-Speed Processing: Delivers execution speeds of 9.5 ns for basic sequence instructions (LD X0) and 19 ns for data movement operations (MOV D0 D1).
  • Large Memory Footprint: Provides 260 K steps (1040 KB) of program memory, supplemented by 1280 KB of standard RAM and 4096 KB of standard ROM.
  • Built-In Communication: Integrated 100/10 Mbps Ethernet port supporting up to 16 simultaneous socket, MELSOFT, or MC protocol connections, plus 1 dedicated FTP channel.
  • Scalable I/O Capacity: Supports up to 4096 local physical I/O points and an extended logical device range of up to 8192 points.
  • Flexible Programming: Native support for Relay symbol words, Logic symbols, MELSAP 3 (SFC), MELSAP-L, Function Blocks, and Structured Text (ST).

Applications

  • High-speed automated packaging and assembly systems.
  • Multi-axis synchronization systems involving complex motion control integration.
  • Water and wastewater plant control network hubs.
  • High-volume data logging, tracking, and MES upstream communication networks.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Mitsubishi Electric
Model / Article Number Q26UDEHCPU (217902)
Control Method Stored program iteration operation
I/O Control Method Refresh method (Direct access I/O possible via DX/DY commands)
LD Instruction Speed 9.5 ns
Program Capacity 260 K steps (1040 KB)
Standard RAM / ROM 1280 KB / 4096 KB
Ethernet Port Speed 100/10 Mbps (Full / Half Duplex)
Internal Current Consumption (5 VDC) 0.49 A
Operating Temperature Range 0 to 55 degC
Storage Temperature Range -25 to 75 degC
Relative Humidity 5 to 95% RH (Non-condensing)
Dimensions (H x W x D) 98 mm x 27.4 mm x 115 mm
Net Module Weight 0.22 kg
Shipping Weight (Calculated) 1.2 kg

Connections and Interfaces

Interface Type Connector / Format Function / Communication Standard
Ethernet Port RJ45 100Base-TX/10Base-T, MC Protocol, FTP Server, Socket Interface
USB Port Mini-B (USB 2.0 High Speed) Direct PC programming connection (GX Works2 / GX Developer)

Empirical Engineering Insights

Alternative Models & Compatibility

When migrating to the Q26UDEHCPU from legacy non-universal hardware such as the Q25HCPU, engineering configurations must be updated in GX Works2. Universal models use a distinct memory organization structure (Standard RAM Drive 3 is handled differently). Additionally, confirm that any installed extension base units support the high-speed bus interfaces associated with Universal CPUs to prevent bus latency errors.

Application Pitfalls & Engineering Notes

This CPU draws 0.49 A from the 5 VDC internal power rail. When configuring multiple CPUs or high-density network modules on a single rack (e.g., combining this CPU with multiple Ethernet/CC-Link IE units), perform a rigorous current consumption calculation. Standard power supplies like the Q61P may approach their operational limit, requiring an upgrade to high-capacity options such as the Q63P or Q64PN.

Commissioning & Wiring Tips

To maintain maximum throughput on the built-in Ethernet port, avoid routing communication patch cords parallel to motor lines or high-voltage lines. Always use Category 5e Shielded Twisted Pair (STP) cabling. If the Ethernet connection drops or times out under heavy factory floor noise, check that the ground terminal (LG/FG) on the main power supply module is securely tied to a dedicated Class D ground.

Installation Guidelines

CRITICAL WARNING: De-energize all primary and auxiliary power systems feeding the rack prior to installing or removing the CPU module. Failing to completely isolate power can lead to internal circuit degradation or destroy the CPU's memory interface pins.
1
Align the lower hook on the back of the CPU module with the base unit guide hole. Ensure it seats flush against the slot.
2
Push the top of the module firmly onto the base plate until the retaining hook clicks into position. Tighten the top fixing screw (if utilizing standard industrial high-vibration mounts).
3
Insert the backup battery connector into the socket located inside the front compartment cover before applying power to prevent cold-start configuration loss.
Loading product navigation…

What software is required to program the Q26UDEHCPU module?

The module requires GX Works2 or GX Developer. Connection is established via the built-in Mini-USB or RJ45 Ethernet port.

What is the internal 5 VDC current draw for the Q26UDEHCPU?

The CPU module draws 0.49 A from the 5 VDC bus. Ensure your rack's power supply module has enough capacity for all fitted components.

Can the built-in Ethernet port be used for Modbus TCP communication?

Yes, but it requires standard socket communication libraries or specialized communication blocks configured inside GX Works2.

Does this CPU unit support multi-CPU setups on the same base unit?

Yes, it supports multi-CPU configurations with a shared high-speed communication memory area of 32 KB for rapid PLC-to-PLC data transfer.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Amerika Serikat

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...