1 dari 1

Omron 3G3MX2-A4030-ZV1 MX2 Series Multi-Function Compact Inverter

Omron 3G3MX2-A4030-ZV1 MX2 Series Multi-Function Compact Inverter

Hanya 6 item tersisa di stok
  • Produsen: Omron

  • Nomor Produk: 3G3MX2-A4030-ZV1

  • Negara asal:Jepang

  • Jenis Produk: Variable Frequency Drives

  • Pembayaran: T/T, Western Union

  • Berat: 4000g

  • Dimensi: 230 x 180 x 200 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed for highly dynamic and precise motor speed control, the Omron 3G3MX2-A4030-ZV1 compact inverter provides reliable three-phase AC power regulation within the MX2 Series architecture. By integrating PM motor control options and sensorless vector performance, this variable frequency drive delivers 200% starting torque at near-zero speeds, making it highly effective for heavy-duty starting cycles. The unit features built-in safety functions conforming to ISO13849-1 Cat 3 PLd, ensuring safe torque-off (STO) without requiring external contactors. The ZV1 designation marks an enhanced functional version supporting custom program logic and seamless system integration.

Features

  • Dual Rating Support: Dual-specification support for Constant Torque (CT) at 3.0 kW and Variable Torque (VT) applications at 4.0 kW.
  • Advanced Vector Control: High starting torque of 200% at 0.5 Hz under sensorless vector control mode.
  • Integrated Safety: Double safety inputs and an external device monitor (EDM) output for direct safety circuit integration.
  • Internal Logic Engine: Built-in DriveProgramming capabilities allowing localized PLC functionality and custom flow sequences.
  • Robust Connectivity: Standard Modbus-RTU RS-485 port integrated on-board, with option cards for EtherCAT, PROFINET, and DeviceNet.

Applications

  • Material Handling: Dynamic conveyor lines, sorting tables, and high-duty cranes requiring precise position/speed profiles.
  • Pumping and Fluid Control: Centrifugal pumps and air handling systems utilizing energy-saving variable torque operations.
  • Packaging Equipment: High-speed wrapping, sealing, and labeling machinery requiring fast acceleration and deceleration response.
  • Industrial Tooling: Rotating spindle drives and auxiliary axes demanding stable torque retention across varying load states.

Technical Specifications

Parameter Specification Value
Manufacturer Omron
Model Number 3G3MX2-A4030-ZV1
Voltage Class 3-phase 400 V AC Class (380 to 480 VAC, +10% / -15%)
Input Frequency 50/60 Hz (+/- 5%)
Max Motor Capacity (Constant Torque) 3.0 kW
Max Motor Capacity (Variable Torque) 4.0 kW
Rated Output Current (CT) 7.2 A
Rated Output Current (VT) 9.2 A
Enclosure Rating IP20 (Panel-mounting / closed wall)
Control Method Phase-controlled sinusoidal PWM (V/f, Sensorless Vector)
Maximum Output Frequency 400 Hz
Cooling Method Forced-air cooling
Ambient Operating Temperature -10 to +50 degC (no derating)
Country of Origin Japan
Net Weight 1.9 kg
Shipping Weight (Calculated) 4.0 kg
Package Dimensions (Calculated) 230 x 180 x 200 mm

Connections and Interfaces

Terminal Symbol Function / Circuit Assignment
L1, L2, L3 3-Phase AC Main Power Input (380-480 V)
U, V, W 3-Phase Motor Output Connections
+1, + DC Link Reactor External Connection Terminals
B1, B2 Dynamic External Braking Resistor Terminals
S1 to S7 Multi-Function Digital Inputs (Sink/Source selectable)
H, O, OI, L Analog Input Terminals (Voltage Reference / Current Reference / Common)

Alternative Models & Compatibility

This model seamlessly replaces older non-ZV1 units (e.g., standard 3G3MX2-A4030). The ZV1 designation features updated internal firmware that expands logic functions via DriveProgramming. Parameter files are compatible and can be transferred using CX-Drive software version 2.9 or higher, though any custom internal PLC logic should be verified to confirm I/O mapping consistency.

Application Pitfalls & Engineering Notes

When operating at low output frequencies (under 10 Hz) under a high constant torque load, ensure the connected motor is auxiliary-cooled or rated for inverter duty. Standard self-cooled motors cannot dissipate heat adequately at low rotational speeds, risking thermal overload. If installing multiple units side-by-side in a control panel, follow specified spacing guidelines or apply current output derating to prevent localized heat accumulation.

Commissioning & Wiring Tips

For stable analog reference signals, connect a dedicated shielded twisted-pair (STP) cable to terminals O/OI and ground the shield at the drive's control common terminal (L) only. Do not apply external voltage to the safety input terminals GS1 and GS2; these must be routed through dry-contact safety devices. If Modbus RTU interface issues arise, verify that parameter C071 (Communication Speed) matches the master network rate and that a 120-ohm termination resistor is active at the end of the trunk.

Installation Guidelines

CRITICAL WARNING: Hazardous voltage remains stored within the internal DC bus capacitors even after AC mains power has been disconnected. Wait a minimum of 10 minutes for complete capacitor charge dissipation before removing the terminal block covers or performing physical wiring operations.
1 Mount the inverter vertically to a rigid, flat surface within an IP54-rated or appropriate industrial enclosure to prevent dust and moisture exposure.
2 Securely ground the drive's main PE terminal to the primary system ground plane using a low-impedance copper conductor.
3 Connect power cables to the L1, L2, and L3 terminals. Verify that phase voltage corresponds precisely with the nominal 400 V AC specification.
4 Route the motor connection wires from U, V, and W terminals using high-quality shielded motor cable to minimize electromagnetic interference (EMI).
Loading product navigation…

What is the difference between the standard 3G3MX2 and the ZV1 revision?

The ZV1 suffix indicates firmware-level enhancements supporting internal DriveProgramming logic and better stability with modern digital network expansion modules.

Can I use the 3G3MX2-A4030-ZV1 with a single-phase input source?

No. The 400V class MX2 drives are designed strictly for 3-phase AC input. Attempting to run on single-phase supply will trigger an input phase loss fault (E12).

What is the recommended external braking resistor resistance?

The minimum allowed resistance for an external braking resistor connected to B1 and B2 on this 3.0 kW / 400 V drive is 180 ohms. Do not connect lower resistance loads.

How do I clear persistent safety circuit faults on this unit?

Verify that both GS1 and GS2 input channels are closed simultaneously. If they are open or out of sync, the drive disables its power stage and displays safe torque-off (STO) codes.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jepang

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...