Omron CJ1W-OD202 CJ1 Series Transistor Output Module

Omron CJ1W-OD202 CJ1 Series Transistor Output Module

Hanya 8 item tersisa di stok
  • Produsen: Omron

  • Nomor Produk: CJ1W-OD202

  • Negara asal:Jepang

  • Jenis Produk: PLC I/O Modules

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Integrating high-capacity switching capabilities directly into the Omron Sysmac architecture, the Omron CJ1W-OD202 provides eight robust sourcing transistor outputs for demanding industrial automation networks. This module is engineered to handle higher-current loads up to 2 A per point, bridging the gap between standard PLC control signals and heavy-duty field actuators. Featuring onboard load short-circuit protection and line disconnection detection, the unit ensures high operational safety and simplified troubleshooting within complex control cabinets.

Features

  • High-Current Capacity: Delivers up to 2 A per output point (8 A maximum per module) for direct control of high-load field devices.
  • Advanced Diagnostics: Built-in load short-circuit protection and line disconnection detection facilitate real-time fault isolation.
  • Automatic Recovery: Features automatic restart functionality once a load short-circuit fault is resolved.
  • Optocoupler Isolation: Protects internal PLC backplane circuitry from external field-side voltage spikes and noise.
  • Removable Terminal Block: Simplifies field wiring and allows rapid module replacement without disconnecting individual terminal leads.

Applications

  • High-load DC contactor and solenoid valve actuation
  • Industrial pneumatic and hydraulic manifold control
  • Heavy-duty indicator panels and signaling beacons
  • Automated packaging systems and material handling machinery

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Code CJ1W-OD202
Output Type Transistor (Sourcing/PNP)
Number of Outputs 8 points
Rated Load Voltage 24 VDC
Operating Load Voltage Range 20.4 to 26.4 VDC
Maximum Load Current 2.0 A per point, 8.0 A per unit
Leakage Current 0.1 mA maximum
Residual Voltage 1.5 V maximum
ON Response Time 0.5 ms maximum
OFF Response Time 1.0 ms maximum
Short-Circuit Protection Detection current: 6 A minimum; Automatic restart
Line Disconnection Detection Detection current: 200 mA (at 24 VDC)
Insulation Resistance 20 MOhm minimum (at 100 VDC) between external and GR terminals
Internal Current Consumption 110 mA maximum (at 5 VDC from PLC bus)
External Power Supply 24 VDC, 50 mA minimum
Weight 120 g (Unit only)
Shipping Weight (Calculated) 1.1 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The CJ1W-OD202 is optimized for high-current loads, delivering 2 A per point over 8 points. This is distinct from standard high-density sourcing units like the CJ1W-OD212 (16 points, 0.5 A per point) or CJ1W-OD232 (32 points, 0.5 A per point). If upgrading from an OD212, verify total system current draws and note that terminal block allocations are not plug-and-play compatible due to the difference in point counts and terminal physical pitches.

Application Pitfalls & Engineering Notes

When switching highly inductive DC loads (such as large solenoid valves or heavy contactor coils), the built-in protection circuits can experience voltage spikes if external freewheeling diodes are omitted. Although the unit contains internal protection, mounting an external diode across the inductive load prevents premature deterioration of the internal sourcing transistors and stabilizes the module's diagnostic feedback loop.

Commissioning & Wiring Tips

Be aware of the short-circuit trip characteristics. The 6 A short-circuit trip mechanism is fast-acting. High-inrush loads (like cold incandescent bulbs or large capacitive circuits) can momentarily exceed this threshold and trigger a fault, causing the output to cycle. For loads with high initial inrush profiles, inline soft-start components or resistive current-limiters are recommended to avoid false trip states.

Installation Guidelines

CRITICAL WARNING: De-energize all PLC backplane power supplies and external 24 VDC field power sources before inserting or removing the CJ1W-OD202 module. Operating under live conditions can cause system fault interrupts, backplane damage, or unexpected field device actuation.
1
Align the top and bottom hooks of the CJ1W-OD202 module carefully with the corresponding slots on the adjacent CJ-series unit or CPU rack.
2
Press the module firmly into the backplane connectors until the yellow slide locks on both top and bottom click securely into the locked position.
3
Wire the external 24 VDC field power supply to the designated terminals, ensuring correct polarity. Connect the return common line back to the control system ground (GR) terminal.
4
Attach the pre-wired removable terminal block back onto the front of the module and tighten the retaining screws to lock the physical interface in place.
Loading product navigation…

What is the maximum output current rating for the CJ1W-OD202?

The module supports up to 2.0 A per point, with a maximum total current rating of 8.0 A per module, divided across two circuits.

Does this module support automatic fault recovery after a short-circuit?

Yes, it features a built-in load short-circuit protection circuit that detects current overloads of 6 A or higher and automatically restarts the output once the fault is cleared.

What happens if a line disconnection occurs on an output?

The module includes line disconnection detection which triggers when the load current drops below 200 mA at 24 VDC, allowing the CPU to flag broken wiring paths.

Is the output logic on this module sourcing (PNP) or sinking (NPN)?

The output logic is sourcing (PNP), meaning the output points supply positive 24 VDC to the connected field loads.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jepang

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...