1 dari 1

Omron E5CN-C2TU E5CN Series Digital Temperature Controller

Omron E5CN-C2TU E5CN Series Digital Temperature Controller

Hanya 4 item tersisa di stok
  • Produsen: Omron

  • Nomor Produk: E5CN-C2TU

  • Negara asal:Jepang

  • Jenis Produk: Digital Temperature Controllers

  • Pembayaran: T/T, Western Union

  • Berat: 500g

  • Dimensi: 48 x 48 mm (depth depends on mounting socket)

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed to deliver precise process thermal control in high-density panel configurations, the Omron E5CN-C2TU is a 1/16 DIN (48 x 48 mm) digital temperature controller engineered for industrial automation environments. This model utilizes a current output as its primary control output, making it highly compatible with modulating control devices such as silicon-controlled rectifiers (SCRs) and analog control valves. Featuring a multi-input architecture, it supports both thermocouples and platinum resistance thermometers (RTD) without requiring hardware reconfiguration. With built-in preventive maintenance functions, including an ON/OFF transition counter for the control outputs, this controller helps track relay degradation and schedule proactive maintenance cycles before field failures occur.

Key Features

  • Universal Input Configuration: Accommodates standard thermocouples and platinum resistance thermometers (Pt100/JPt100) within a single hardware variant.
  • Enhanced Processing Accuracy: Delivers precise PV indication accuracy of +/-0.3% for thermocouple inputs and +/-0.2% for RTD inputs.
  • Dual Auxiliary Outputs: Includes 2 independent auxiliary relay outputs for configuring safety limits, system interlocks, or process alarms.
  • PV/SV Status Display Function: Configurable to automatically alternate between the Process Value (PV) / Setpoint Value (SV) and active controller states such as auto/manual modes, RUN/STOP status, and alarm triggers.
  • Convenient Plug-in Design: The U-type configuration allows rapid controller body replacement from the front of the panel without disrupting terminal socket wiring.

Applications

  • Plastic extrusion and injection molding thermal zone management.
  • Industrial ovens, heat-treating chambers, and packaging seal jaw heaters.
  • Food processing pasteurizers, sterilizers, and tempering systems.
  • Environmental testing chambers and climate simulation systems.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model E5CN-C2TU
Product Class Basic-type Digital Temperature Controller (1/16 DIN)
Supply Voltage 100 to 240 VAC, 50/60 Hz
Dimensions 48 x 48 mm (depth depends on mounting socket)
Primary Control Output Current Output (4 to 20 mA DC / 0 to 20 mA DC)
Auxiliary Outputs 2 SPST-NO relay outputs
Input Formats Thermocouple or Resistance Thermometer (RTD)
Indication Accuracy Thermocouple: +/-0.3% of PV | RTD: +/-0.2% of PV
Base/Terminal Type Plug-in Model (Requires 11-pin socket)
Housing Color Black
Shipping Weight (Calculated) 1.1 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The E5CN-C2TU plug-in design is specifically intended for systems requiring rapid serviceability. It interfaces directly with standard Omron 11-pin sockets (such as P2CF-11 or P3GA-11). When replacing older E5CN generation controllers, confirm if the original unit was a direct screw-terminal type (E5CN-C2T) or a plug-in type (E5CN-C2TU); a standard terminal-block model cannot plug into an 11-pin base without replacing the housing and socket wiring assembly.

Application Pitfalls & Engineering Notes

Because this controller utilizes an analog current output (4-20 mA DC), pay close attention to the allowable load impedance of the receiving control device (e.g., SCR driver or modulating valve positioner). Exceeding the controller's maximum load resistance limit will cause output saturation and non-linear control loops. Additionally, ensure the sensor cabling is completely segregated from power distribution paths to prevent induced high-frequency electrical noise from degrading PV reading accuracy.

Commissioning & Wiring Tips

When using thermocouple inputs, always ensure that the correct cold-junction compensation is active and that only matched thermocouple compensation wires are used for panel routing. For 3-wire RTD configurations, verify that all three lead wires have identical electrical resistance; any imbalance between the A, B, and B' lines will introduce systematic offset errors in the PV reading.

Installation Guidelines

CRITICAL WARNING: SAFETY FIRST

Before installing or removing the controller body from its socket, ensure the mains power supply (100 to 240 VAC) and all auxiliary contact circuit voltages are fully de-energized. Failure to disconnect active electrical power before extraction can result in electrical arcing, damage to the controller internal logic boards, or severe personal injury.

1
Ensure the cutout dimensions in the control panel face are exactly 45.0 mm x 45.0 mm (+0.6/-0 mm tolerance) for standard 1/16 DIN mounting.
2
Secure the matching 11-pin socket (e.g., P3GA-11 for rear-mounting or P2CF-11 for DIN-rail/front-mounting) within your panel enclosure, following the specified terminal block wiring layout for power supply inputs on pins 5 and 6.
3
Align the keyway guide on the rear plug of the E5CN-C2TU controller with the center indexing hole of the wired 11-pin socket. Push the controller firmly inward until it seats flush and the securing side clips click into locked positions.
Loading product navigation…

What is the primary control output of the E5CN-C2TU?

The E5CN-C2TU features an analog current output (typically 4-20 mA DC or 0-20 mA DC), which is designed for modulating actuators, SCR power control boards, or control valves.

Does this controller model have screw terminals directly on its casing?

No. The 'U' suffix in E5CN-C2TU indicates that it is a plug-in model. It requires an external 11-pin base socket (such as P2CF-11 or P3GA-11) for physical wiring connection.

What sensor types can be connected to this temperature controller?

This controller supports universal inputs, meaning it is compatible with standard thermocouples (such as K, J, T, E, L, etc.) and platinum resistance thermometers (RTDs like Pt100 and JPt100) selectable via the system menus.

How do the dual auxiliary outputs function on this controller?

The two auxiliary outputs are independent SPST-NO relay contacts that can be configured for process alarms (high, low, band limits), diagnostic error warnings, or basic interlock sequencing.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jepang

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...