1 dari 1

Omron K3HB-RNB-C2 K3HB Series Digital Rotary Pulse Indicator

Omron K3HB-RNB-C2 K3HB Series Digital Rotary Pulse Indicator

Hanya 8 item tersisa di stok
  • Produsen: Omron

  • Nomor Produk: K3HB-RNB-C2

  • Negara asal:Jepang

  • Jenis Produk: Digital Rotary Pulse Indicators

  • Pembayaran: T/T, Western Union

  • Berat: 1500g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Engineered for high-speed rotational measurement, the Omron K3HB-RNB-C2 serves as a highly precise digital rotary pulse indicator within demanding industrial automation frameworks. Designed to support rotary pulse inputs up to 50 kHz, this device provides instantaneous, high-resolution velocity and rotation metrics. The unit integrates an NPN/voltage pulse sensor input configuration and utilizes four independent SPST-NO relay outputs for critical limit monitoring (HH, H, L, LL). Its multi-color display dynamically changes color based on alarm status, providing field operators with immediate visual confirmation of system performance.

Features

  • High-Speed Pulse Processing: Capable of accurate signal evaluation up to 50 kHz for rapid shaft rotation and line speed monitoring.
  • Versatile Sensor Input: Designed to interface natively with NPN open-collector or voltage pulse sensors.
  • Quad Limit Relay Outputs: Provides dedicated SPST-NO contacts for High-High (HH), High (H), Low (L), and Low-Low (LL) limit controls.
  • Dynamic Visual Feedback: Visual alert status communicated through a dual-color process value display.
  • Robust Environment Adaptation: Engineered to maintain operations in ambient temperatures ranging from -10 to 55 degC.

Applications

  • Rotational speed (RPM) monitoring of industrial electric motors and turbines.
  • Conveyor line velocity tracking and throughput measurement in packaging systems.
  • Flow meter pulse integration for volumetric rate monitoring.
  • Operational safety interlock systems requiring overspeed or underspeed trip detection.

Technical Specifications Table

Parameter Value / Specification
Manufacturer Omron
Model Number K3HB-RNB-C2
Product Series K3HB Series
Input Sensor Code NB (NPN input / voltage pulse input)
Relay Output Configuration C2 (Relay contact: HH, H, LL, L; SPST-NO each)
Nominal Supply Voltage 100 to 240 VAC
Maximum Measurement Frequency 50 kHz
Ambient Operating Temperature -10 to 55 degC (no icing or condensation)
Ambient Operating Humidity 25% to 85% RH
Storage Temperature Range -25 to 65 degC
Maximum Operating Altitude 2000 m
Device Base Weight Approx. 300 g
Shipping Weight (Calculated) 1.5 kg

Empirical Engineering Insights

Alternative Models & Compatibility

The K3HB series serves as the modern standard update to legacy Omron K3N indicators. While functional similarities exist, please note that wiring structures and rear terminal blocks differ significantly. Panel cutouts are standardized, but back-of-panel depth clearances must be verified during system retrofits to accommodate the output terminal configuration on the K3HB-RNB-C2.

Application Pitfalls & Engineering Notes

When utilizing the maximum 50 kHz measurement range, standard sensor wiring is highly susceptible to electromagnetic interference (EMI). Run signal lines in independent, grounded steel conduits separate from high-current motor leads or Variable Frequency Drive (VFD) output cables to prevent false triggering. Keep the cable length to the sensor as short as possible to prevent signal attenuation.

Commissioning & Wiring Tips

Ensure that the internal parameter settings match the connected sensor type (NPN open-collector versus voltage pulse). Failing to configure this software parameter correctly may result in zero pulse registration or risk overloading the internal signal pull-up circuit. Always apply shielded twisted-pair (STP) cabling for the input connections.

Installation Guidelines

CRITICAL WARNING: Prior to wiring or mounting the K3HB-RNB-C2 unit, verify that all incoming AC power distribution sources are physically locked out and tagged out. Hazardous voltages remain present on terminal contacts during operation. Do not touch terminals while supply power is active.
1

Prepare a standardized 1/8 DIN panel cutout (92 mm x 45 mm) and slide the unit through the panel front, ensuring the rubber sealing gasket is flat against the surface.

2

Secure the unit into the panel using the provided side mounting fixtures, tightening the screws evenly to ensure a secure dust and water-resistant fit.

3

Attach the sensor input cables to the designated NB terminals using properly sized crimped ferrule connectors to ensure permanent gas-tight contacts.

4

Connect the 100 to 240 VAC power line to the primary power input terminals, re-check terminal polarity, and proceed to device parameter configuration.

Loading product navigation…

What sensor types are compatible with the NB input on the K3HB-RNB-C2?

The NB input code signifies compatibility with NPN open-collector transistors and solid-state voltage pulse sensors.

Can the C2 relay output block be configured for NC operation?

No, the C2 output board features four independent SPST-NO (normally open) relay contacts for the HH, H, L, and LL alarm thresholds.

What is the maximum operating frequency of this rotary pulse meter?

The K3HB-RNB-C2 is rated for high-speed measurement applications up to a maximum input frequency of 50 kHz.

What is the standard operating voltage for this unit?

This model is designed to operate on a standard power supply range of 100 to 240 VAC.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jepang

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...