Description

Direct human-machine interface interaction is established through the Omron NS5-MQ11-V2, a reliable monochrome terminal engineered for integration within the Omron NS Series architecture. This unit provides a highly functional visual interface for machine-level monitoring and control, housing a robust display in a durable panel-mount form factor. Configured with dual RS-232C ports, it coordinates seamless communication with host PLCs, temperature controllers, and auxiliary devices. Designed for operational longevity, this model features an ivory bezel that integrates cleanly with classic industrial control cabinets.

Features

  • Monochrome STN Display: Offers clear legibility for alarms, status registers, and process variables at a standard 320 x 240 pixel resolution.
  • Dual Serial Connectivity: Features two independent RS-232C interfaces for multi-device or dual-protocol configurations.
  • Dedicated Programming Interface: Integrated USB slave port allows high-speed screen data transfer and debugging directly from CX-Designer.
  • Memory Expansion Slot: Rear-accessible slot supports standard CompactFlash cards for backup, data logging, and system firmware updates.
  • High-Durability Bezel: IP65F front-panel rating provides robust protection against ingress of moisture and fine particulate matter in harsh environments.

Applications

  • Packaging Machinery: Local machine control panels requiring fast screens, recipe modification, and alarm status tracking.
  • Material Handling: Monitoring conveyor speeds, diverter status, and sorting criteria on localized nodes.
  • Process Subsystems: Interface terminal for localized water treatment, environmental chambers, or basic raw material dosing units.

Technical Specifications

Manufacturer Omron
Model Reference NS5-MQ11-V2
Series NS Series
Display Type STN Monochrome LCD
Display Size 5.7 inches
Resolution 320 x 240 pixels (QVGA)
Input Voltage 24 VDC (Acceptable range: 20.4 to 27.6 VDC)
Power Consumption 15 Watts maximum
Serial Communications 2x RS-232C Ports
USB Ports 1x USB Type-B Slave (USB 1.1)
Case Color Ivory
Operating Temperature 0 to 50 degC
Front Panel Protection IP65F equivalent
Country of Origin Japan
Shipping Weight (Calculated) 1.5 kg
Package Dimensions (Calculated) 24.5 cm x 19.2 cm x 8.5 cm

Connections and Interfaces

Port Reference Connector Type Functional Assignment / Signal Mapping
Serial Port A D-Sub 9-pin Female Host Link / NT Link RS-232C serial connection to PLC CPU.
Serial Port B D-Sub 9-pin Female Auxiliary serial communications (RS-232C), peripheral devices, or temperature controllers.
USB Tool Port USB Type-B (Slave) Dedicated interface for high-speed programming, screen downloads, and online system debugging.
Power Input Terminal M3.5 Screw Terminal Block 24 VDC Power Input along with functional ground (FG) terminal for noise abatement.

Empirical Engineering Insights

Alternative Models & Compatibility

The "V2" suffix represents upgraded internal processing and expanded compatibility with newer runtime versions compared to legacy V1 variants. Note that the NS5-MQ11-V2 (Ivory bezel) is chemically and structurally identical in internal operation to the NS5-MQ11B-V2 (Black bezel), permitting direct drop-in substitution when bezel aesthetics are not critical. Software configuration projects built in CX-Designer can target either color variant without modification.

Application Pitfalls & Engineering Notes

Because this unit utilizes a monochrome STN LCD, viewing angles and response latency can be more pronounced compared to modern TFT equivalents. When designing HMI screens, maintain high-contrast graphic layouts (solid black/white configurations rather than gradient shades) to preserve visibility in direct plant floor lighting. Ensure the rear ventilation slot is unblocked; operation inside enclosures exceeding 50 degC will significantly accelerate CCFL backlight degradation.

Commissioning & Wiring Tips

To protect against communication time-outs and localized ground loop disruption, dedicated 24 VDC supply routing is recommended. Keep serial RS-232C lines isolated from high-voltage motor starters and variable frequency drive cables. Always verify the functional ground terminal is tied back to a solid low-impedance earth connection using a wire size of at least 2.0 mm².

Installation Guidelines

CRITICAL WARNING

Isolate and verify de-energization of the primary power supply source before working on the 24 VDC terminals. Do not service the power connector, change the system configuration, or adjust wiring while voltage is applied to avoid physical shock or severe control system damage.

1 Ensure the panel cutout dimensions conform exactly to the physical specs of 184 mm x 131 mm.
2 Seat the waterproofing gasket completely around the inner bezel lip before inserting the unit into the cutout.
3 Tighten the included mounting brackets evenly to a torque of 0.5 to 0.6 N-m to achieve a proper IP65F seal without cracking the bezel.
4 Terminate the 24 VDC power lines using insulated crimp terminals on the M3.5 screws. Ensure polarity is strictly maintained.
Loading product navigation…

What is the structural difference between the NS5-MQ11-V2 and the NS5-MQ11B-V2?

The only difference is the physical enclosure color. The NS5-MQ11-V2 has an ivory-colored front bezel, whereas the NS5-MQ11B-V2 has a black bezel. Internally, all electrical specifications, software requirements, and communications are identical.

Can I program the NS5-MQ11-V2 via an Ethernet connection?

No, the NS5-MQ11-V2 is a serial-only base terminal. Screen transfer and firmware operations must be performed using either the dedicated USB slave port connected directly to a PC running CX-Designer, or via a formatted CompactFlash card in the expansion slot.

Does this model support direct NT Link communications?

Yes. Both integrated serial ports support high-speed 1:1 and 1:N NT Link protocols, alongside Host Link, for seamless data exchange with compatible Omron Sysmac PLCs.

What software is used to design and download screens for this HMI?

The Omron NS5-MQ11-V2 is configured using the CX-Designer software, which is part of the comprehensive CX-One software suite. It is highly recommended to use CX-Designer version 3.0 or higher.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jepang

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...