1 dari 1

Omron NX-RS1201 NX Series Load Cell Input Unit

Omron NX-RS1201 NX Series Load Cell Input Unit

Hanya 3 item tersisa di stok
  • Produsen: Omron

  • Nomor Produk: NXRS1201

  • Negara asal:Jepang

  • Jenis Produk: Load Cell Input Units

  • Pembayaran: T/T, Western Union

  • Berat: 70g

  • Dimensi: 12 mm x 100 mm x 71 mm

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Engineered for high-speed, high-accuracy weighing applications, the Omron NX-RS1201 operates as a high-performance weight and force measurement module within the Sysmac automation platform. This high-performance module interfaces directly with strain-gauge load cells, converting raw analog force signals into highly precise digital data. Designed for seamless integration into EtherCAT and EtherNet/IP networks via NX-series coupler units, the Omron NX-RS1201 features an ultra-fast conversion cycle of 125 microseconds and a 24-bit A/D converter. Its support for Synchronous I/O refreshing allows exact timing coordination with motion control processes, making it highly effective for dynamic checkweighers, filling systems, and tension control applications.

Key Features

  • Ultra-precise 24-bit analog-to-digital conversion resolution.
  • High-speed 125-microsecond conversion cycle for real-time force measurement.
  • Flexible I/O refreshing options including Synchronous, Free-Run, and Task Period Prioritized refreshing.
  • Built-in stable 5 VDC (+/- 10%) load cell excitation voltage output.
  • Space-saving 12 mm wide profile to minimize DIN rail footprint.
  • Vibration-resistant screwless push-in clamping terminal block (16 points) for rapid field installation.

Applications

  • High-speed industrial checkweighers and packaging machinery.
  • Continuous filling, dosing, and batching systems.
  • Web tension measurement and winding control in paper and film processing.
  • Material testing machines and press-fit force monitoring systems.

Technical Specifications

Specification Parameter Value / Rating
Manufacturer Omron
Model Number NX-RS1201
Product Type Load Cell Input Unit
Number of Points 1 Channel
A/D Converter Resolution 24 bits
Conversion Cycle 125 microseconds
Input Range -5.0 to 5.0 mV/V
Input Conversion Range -5.5 to 5.5 mV/V
Load Cell Excitation Voltage 5 VDC (+/- 10%), 60 mA maximum output current
Zero / Gain Adjustment Range -5.0 to 5.0 mV/V
Nonlinearity +/-0.01% of full scale
Zero Drift +/-0.1 microvolt per degC RTI (Refer to Input)
Gain Drift +/-10 ppm per degC
Warm-Up Period 30 minutes minimum
External Connection Terminals Screwless clamping terminal block (16 terminals)
Dimensions (W x H x D) 12 mm x 100 mm x 71 mm
Product Weight 0.07 kg
Shipping Weight (Calculated) 1.00 kg (including protective packaging)
Country of Origin Japan

Empirical Engineering Insights

Alternative Models & Compatibility

The NX-RS1201 is fully integrated into the Omron Sysmac platform via NX-series Bus Couplers. When replacing legacy analog input modules, ensure that the target Sysmac Studio project configuration is updated to support this unit's 24-bit output structure. Firmware compatibility must be verified with the controller unit: an NJ-series, NX-series, or NY-series controller requires firmware version 1.10 or higher for full Synchronous I/O operational modes.

Application Pitfalls & Engineering Notes

Because of its ultra-high resolution, the 24-bit A/D converter is highly sensitive to ambient temperature changes. For applications requiring precise measurements, the module requires a full 30-minute warm-up period to stabilize thermal drift coefficients. If the control panel is located near heat-generating equipment (such as variable frequency drives or large transformers), forced ventilation is highly recommended to maintain a steady ambient temperature and prevent drift.

Commissioning & Wiring Tips

To maintain maximum measurement integrity, avoid running the load cell signal cables in parallel with high-voltage AC power lines. Utilize double-shielded, twisted-pair cables for excitation and signal paths. The cable shield must be terminated at a single point—preferably at the functional ground terminal of the NX-series system—to prevent ground loops that introduce electrical noise to the microvolt-level inputs.

Installation Guidelines

CRITICAL SAFETY WARNING

Turn off all power supplies to the PLC rack and field devices before installing, removing, or wiring the module. Failure to de-energize equipment can result in electrical shock, equipment damage, or erratic system behavior.

1
Align the guide hooks on the side of the NX-RS1201 with the adjacent module or bus coupler, then slide the unit onto the DIN rail until it clicks securely into place.
2
Strip the load cell connection wires to the recommended length (typically 8 to 10 mm) and insert them directly into the push-in screwless clamp terminals. Ensure the Excitation (+/-) and Signal (+/-) polarities match your load cell specifications.
3
Connect the functional ground wire to the designated grounding terminal and apply power to the system. Allow the unit to warm up for 30 minutes before executing the zero-point and span calibration through Sysmac Studio.

What is the resolution of the A/D converter on the NX-RS1201?

The module is equipped with a high-performance 24-bit A/D converter, providing superior resolution for microvolt-level force and weight measurement.

How fast is the conversion cycle for this load cell module?

The unit features an ultra-fast conversion cycle of 125 microseconds, making it suitable for dynamic and high-speed weighing systems.

Does this module require a specific warm-up period before calibration?

Yes, to ensure accurate measurement and minimize thermal drift errors, a minimum warm-up period of 30 minutes is required after power-up.

What type of terminals are used for field connections?

It utilizes a 16-point screwless clamping terminal block, facilitating reliable, tool-free wiring that is highly resistant to industrial vibrations.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jepang

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Listrik yang Dirancang untuk Menggantikan Sistem Tenaga Fluida: Panduan Praktis Otomasi Industri

Artikel ini menjelaskan bagaimana aktuator listrik terintegrasi, seperti seri e-Actuator dari SMC, mengubah kontrol gerak industri dengan menggantikan sistem pneumatik dan hidrolik tradisional....

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...