1 dari 1

Omron V680-HA63B V680 Series RFID Amplifier Unit

Omron V680-HA63B V680 Series RFID Amplifier Unit

Hanya 5 item tersisa di stok
  • Produsen: Omron

  • Nomor Produk: V680-HA63B

  • Negara asal:Jepang

  • Jenis Produk: RFID Amplifier Units

  • Pembayaran: T/T, Western Union

  • Berat: 2000g

  • Pelabuhan pengiriman: Xiamen

  • Garansi: 12 bulan

Jumlah
Lihat detail lengkap

Description

Designed for high-performance industrial RFID tracking, the Omron V680-HA63B serves as a dedicated RFID Amplifier Unit within the V680 series ecosystem. This module bridges the physical read/write antennas with upstream ID controllers, ensuring reliable signal transmission and high-speed data processing. It is engineered to interface seamlessly with both 2-kbyte and 8-kbyte memory tags, making it a highly adaptable component for tracking, sorting, and positioning applications in demanding industrial environments.

Features

  • Dual-Memory Support: Fully compatible with both 2-kbyte and 8-kbyte high-capacity FRAM/EEPROM RFID tags.
  • Robust Environmental Protection: IP67/IP65 rated outer housing ensures total resistance to dust and low-pressure water jets, ideal for harsh production floors.
  • High-Speed Signal Processing: Minimizes read/write cycle latency to optimize conveyor speeds and throughput rates.
  • Flexible Antenna Integration: Interfaces with V680-HS series read/write antennas through dedicated industrial connectors.
  • Compact Form Factor: Small footprint designed for simple DIN-rail or panel mounting inside local junction boxes.

Applications

  • Automotive powertrain assembly and body-in-white tracking lines.
  • Automated pallet routing and sorting systems in logistics hubs.
  • Work-in-progress (WIP) tracking in pharmaceutical and food processing facilities.
  • Tooling identification and status monitoring on CNC machining centers.

Technical Specifications

Parameter Specification
Manufacturer Omron
Model Number V680-HA63B
Product Type RFID Amplifier Unit
Compatible Memory Capacities 2-kbyte, 8-kbyte
Degree of Protection IP67/IP65 (IEC 60529)
Ambient Operating Temperature -10 to 55 degC (with no icing)
Ambient Storage Temperature -25 to 65 degC (with no icing)
Net Weight 0.65 kg
Shipping Weight (Calculated) 2.0 kg

Alternative Models & Compatibility

The V680-HA63B is part of the modular V680 series. It is designed to work exclusively with V680-HS series Read/Write Antennas (such as V680-HS52 or V680-HS63) and V680-CA5D01-V2 / CS1W-V680C11 Controllers. Do not attempt to pair this unit with newer V680S series integrated reader/writers, as they utilize completely different physical layer and protocol specifications.

Application Pitfalls & Engineering Notes

To prevent read/write errors caused by electromagnetic interference (EMI), keep all antenna and amplifier cabling separated from high-voltage lines, servo motor cables, and variable frequency drives (VFDs) by a minimum of 200 mm. Avoid mounting the amplifier directly onto highly vibrating metal frames without vibration-damping mounts, as sustained harmonic resonance can stress internal PCB joints over time.

Commissioning & Wiring Tips

Always use the proprietary shielded cables supplied by Omron for antenna-to-amplifier connections. Ensure that the ground terminal (FG) of the connected ID controller is tied to an independent Class D ground (grounding resistance of 100 ohms or less). When configuring system parameters in your PLC, match the controller transmission speed settings with the selected tag type to prevent communications timeout faults (E70/E72).

Installation Guidelines

CRITICAL WARNING

Always completely isolate the main power source before mounting, wiring, or servicing the V680-HA63B. Connecting or disconnecting the antenna or controller cables while the system is energized may cause catastrophic dielectric breakdown of the amplifier's internal RF circuitry.

1

Mount the amplifier unit securely onto a standard 35 mm DIN rail or directly to a flat panel using the integrated mounting brackets.

2

Connect the compatible V680-HS series Read/Write Antenna to the designated port, ensuring the locking collar is fully threaded and sealed to maintain the IP rating.

3

Run the controller connection cable to the ID Controller unit, observing minimum bend radius limitations and keeping distance from electromagnetic noise sources.

4

Apply power to the ID Controller and verify that the amplifier's status indicator LEDs align with normal operational parameters.

Loading product navigation…

Which RFID tags are compatible with the V680-HA63B?

This amplifier unit is fully compatible with both 2-kbyte and 8-kbyte memory RFID tags within the Omron V680 product range, supporting standard FRAM and EEPROM variants.

What is the ingress protection rating of this module?

The module features an IP67/IP65 (IEC 60529) ingress protection rating, making it highly resistant to dust and water ingress in demanding industrial environments.

Can I hot-swap the antenna cable while the amplifier is powered?

No. You must completely de-energize the connected ID controller before plugging or unplugging the antenna cable to prevent permanent electrical damage to the RF transceiver stage.

What are the grounding requirements for this RFID system?

To prevent communication errors from electrical noise, the system must be grounded via a dedicated Class D ground with a grounding resistance of 100 ohms or less connected to the controller.

Pengiriman Ekspres Global

  • Pengiriman Standar: 4-6 Hari Kerja melalui DHL, FedEx, dan UPS.
  • Pengiriman Ekspres: Pengiriman pada hari yang sama untuk pesanan dalam stok yang dilakukan sebelum pukul 14:00 (GMT+8).
  • Cakupan Seluruh Dunia: Melayani lebih dari 150 negara, termasuk pengiriman cepat ke Arab Saudi dan UAE.

Pengembalian & Garansi

  • Jaminan 30 Hari: Pengembalian diterima untuk produk yang tersedia dalam stok dengan kemasan asli yang tersegel pabrik.
  • Garansi 12 Bulan: Setiap komponen industri didukung oleh garansi teknis profesional kami.

Pesanan diproses dan dikirimkan Senin-Jumat (tidak termasuk hari libur nasional).


Untuk kelayakan penuh, biaya pengisian ulang, dan detail pengembalian internasional, silakan lihat resmi kami Kebijakan Pengembalian & Pengembalian Dana .

TECHNICAL SPECIFICATIONS

Country of origin
Jepang

Produk yang Baru Dilihat

Pengetahuan teknis

Aktuator Elektrik yang Dirancang untuk Menggantikan Cairan: Tutorial Praktis

This article explains how integrated electric actuators, such as SMC’s e-Actuator series, are transforming industrial motion control by replacing traditional pneumatic and hydraulic systems. It...

Operasi Matematika Menggunakan OpenPLC untuk Aplikasi Otomasi Industri

Artikel ini menjelaskan bagaimana sistem PLC melakukan operasi matematika inti seperti penjumlahan, pengurangan, perkalian, pembagian, modulo, dan perpangkatan dalam otomasi industri. Artikel ini...

Logika Boolean Lanjutan dengan Pemrograman FBD PLC: Aplikasi Industri Praktis di Luar Logika Dasar

Artikel ini menjelaskan beberapa fungsi logika Boolean lanjutan yang digunakan dalam pemrograman PLC selain operasi dasar AND, OR, dan NOT. Artikel ini membahas bagaimana alat seperti tabel...

Logika Boolean dalam Pemrograman PLC: Memahami Gerbang Logika FBD

Logika Boolean adalah dasar dari setiap program PLC. Dari kontrol mesin sederhana hingga sistem otomasi industri yang kompleks, gerbang logika menentukan bagaimana pengendali merespons perubahan...

Panduan Mendalam tentang Firewall Industri dan Segmentasi Jaringan OT

Firewall industri memainkan peran penting dalam keamanan siber OT, melindungi jaringan PLC, DCS, dan SCADA melalui segmentasi, kontrol masuk/keluar, dan integrasi IDS/IPS yang sesuai dengan prinsip...

Panduan Gripper Robotik: Dari Penanganan Halus hingga Otomasi Berat

Gripper robot modern berkembang melampaui rahang mekanis tradisional. Mulai dari sistem adhesif yang terinspirasi oleh cicak dan gripper lembut yang aman untuk makanan hingga alat gudang bertenaga...